PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

String inverter 2 exact records
Edit selection
Inverter electrical comparison
SpecificationGW100K-GT-L-G10GoodWe Technologies Co., Ltd. · Global catalog (country/grid/voltage exceptions separated as material variants)Deep comparison fields reviewedFronius Primo GEN24 3.0Fronius International GmbH · Europe / ROW current support selectorDeep comparison fields reviewed
AC output
Rated AC active power100000 WNominal output power; exact source raw value '100 kW' kW. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
3000 WAC nominal output (P_ac,r)
Official source ↗
Maximum AC apparent output100000 VAMax AC apparent power; exact source raw value '100 kVA' kVA. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
3000 VAMax. output power (P_ac max); apparent-power unit preserved
Official source ↗
Connection phases3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained.
Official source ↗
1Task23 QC-approved exact-model/market manufacturer specification.
Official source ↗
PV input & tracking
Independent MPPT trackers10MPP trackers; exact model/market Task10 evidence reused.
Official source ↗
2Number of MPP trackers
Official source ↗
MPPT operating window minimum180 VMPPT operating range; endpoint of exact official range [180, 900], not the absolute DC limit.
Official source ↗
190 VMPP voltage range
Official source ↗
MPPT operating window maximum900 VMPPT operating range; endpoint of exact official range [180, 900], not the absolute DC limit.
Official source ↗
530 VMPP voltage range
Official source ↗
DC operating voltage minimumUnknown65 VU_dc min - U_dc max
Official source ↗
DC operating voltage maximumUnknown600 VU_dc min - U_dc max
Official source ↗
Maximum PV input voltage900 VMax input voltage; exact model/market Task10 evidence reused.
Official source ↗
600 VTask23 QC-approved exact-model/market manufacturer specification.
Official source ↗
Maximum input current per tracker/input42 AMax input current per MPPT; per-MPPT/input maximum, not total inverter current.
Official source ↗
MPPT1 22 / MPPT2 12 AMax. input current (I_dc max), manufacturer two-MPPT topology preserved
Official source ↗
Maximum PV short-circuit current52.5 AMax short circuit current per MPPT; per-MPPT/input maximum, not total inverter current.
Official source ↗
MPPT1 41.25 / MPPT2 22 AMax. short circuit current, module array; exact two-MPPT scope
Official source ↗
Efficiency & environment
Maximum conversion efficiency98.8 %Max efficiency; exact model/market Task10 evidence reused.
Official source ↗
97.6 %Max. efficiency (PV-grid)
Official source ↗
European efficiency98.3 %European efficiency; exact model/market Task10 evidence reused.
Official source ↗
Unknown
Operating ambient temperature minimum-30 °COperating temp; lower endpoint of exact official range [-30, 60].
Official source ↗
-40 °CAmbient temperature range; no extra derating curve inferred
Official source ↗
Operating ambient temperature maximum60 °COperating temp; upper endpoint of exact official range [-30, 60].
Official source ↗
60 °CAmbient temperature range; no extra derating curve inferred
Official source ↗
Enclosure protectionIP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval.
Official source ↗
IP66Degree of protection
Official source ↗
Surge protectionDC: Type II (Type I + II optional); AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated.
Official source ↗
Unknown
Warranty
Warranty and eligibilityUnknownUnknown