Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
String inverter
2 exact records
Edit selection
| Specification | GW100K-GT-L-G10GoodWe Technologies Co., Ltd. · Global catalog (country/grid/voltage exceptions separated as material variants)Deep comparison fields reviewed | Fronius Primo GEN24 3.0Fronius International GmbH · Europe / ROW current support selectorDeep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 100000 WNominal output power; exact source raw value '100 kW' kW. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ | 3000 WAC nominal output (P_ac,r) Official source ↗ |
| Maximum AC apparent output | 100000 VAMax AC apparent power; exact source raw value '100 kVA' kVA. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ | 3000 VAMax. output power (P_ac max); apparent-power unit preserved Official source ↗ |
| Connection phases | 3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained. Official source ↗ | 1Task23 QC-approved exact-model/market manufacturer specification. Official source ↗ |
| PV input & tracking | ||
| Independent MPPT trackers | 10MPP trackers; exact model/market Task10 evidence reused. Official source ↗ | 2Number of MPP trackers Official source ↗ |
| MPPT operating window minimum | 180 VMPPT operating range; endpoint of exact official range [180, 900], not the absolute DC limit. Official source ↗ | 190 VMPP voltage range Official source ↗ |
| MPPT operating window maximum | 900 VMPPT operating range; endpoint of exact official range [180, 900], not the absolute DC limit. Official source ↗ | 530 VMPP voltage range Official source ↗ |
| DC operating voltage minimum | Unknown | 65 VU_dc min - U_dc max Official source ↗ |
| DC operating voltage maximum | Unknown | 600 VU_dc min - U_dc max Official source ↗ |
| Maximum PV input voltage | 900 VMax input voltage; exact model/market Task10 evidence reused. Official source ↗ | 600 VTask23 QC-approved exact-model/market manufacturer specification. Official source ↗ |
| Maximum input current per tracker/input | 42 AMax input current per MPPT; per-MPPT/input maximum, not total inverter current. Official source ↗ | MPPT1 22 / MPPT2 12 AMax. input current (I_dc max), manufacturer two-MPPT topology preserved Official source ↗ |
| Maximum PV short-circuit current | 52.5 AMax short circuit current per MPPT; per-MPPT/input maximum, not total inverter current. Official source ↗ | MPPT1 41.25 / MPPT2 22 AMax. short circuit current, module array; exact two-MPPT scope Official source ↗ |
| Efficiency & environment | ||
| Maximum conversion efficiency | 98.8 %Max efficiency; exact model/market Task10 evidence reused. Official source ↗ | 97.6 %Max. efficiency (PV-grid) Official source ↗ |
| European efficiency | 98.3 %European efficiency; exact model/market Task10 evidence reused. Official source ↗ | Unknown |
| Operating ambient temperature minimum | -30 °COperating temp; lower endpoint of exact official range [-30, 60]. Official source ↗ | -40 °CAmbient temperature range; no extra derating curve inferred Official source ↗ |
| Operating ambient temperature maximum | 60 °COperating temp; upper endpoint of exact official range [-30, 60]. Official source ↗ | 60 °CAmbient temperature range; no extra derating curve inferred Official source ↗ |
| Enclosure protection | IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval. Official source ↗ | IP66Degree of protection Official source ↗ |
| Surge protection | DC: Type II (Type I + II optional); AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ | Unknown |
| Warranty | ||
| Warranty and eligibility | Unknown | Unknown |