Fronius International GmbH
Fronius International GmbH Fronius Primo GEN24 3.0
Primo GEN24
String inverter
Fronius International GmbH Fronius Primo GEN24 3.0 has a reviewed nominal AC active-power rating of 3000 W.
Deep comparison fields reviewedThis local comparison record does not approve module compatibility, string sizing, grid connection or electrical safety.
Documented source scope: Europe / ROW current support selector. This is not a statement about your location or product availability. Exact Task23 QC-approved identity/market retained; no cross-market or family interpolation.
Representative illustration — not the manufacturer’s exact hardware appearance.
Field-level provenance
Electrical specifications
Unknown means the field has not passed this exact-record integration review. It does not mean zero.
| AC output | |
|---|---|
| Rated AC active power | 3000 WAC nominal output (P_ac,r) Official source ↗ · Technical Data > Output Data Revision: Unknown · Checked 2026-10-02 |
| Maximum AC apparent output | 3000 VAMax. output power (P_ac max); apparent-power unit preserved Official source ↗ · Technical Data > Output Data Revision: Unknown · Checked 2026-10-02 |
| Connection phases | 1Task23 QC-approved exact-model/market manufacturer specification. Official source ↗ · exact model identity; DC voltage/current/MPPT; AC nominal active W; max apparent VA; grid voltage/frequency Revision: Unknown · Checked 2026-10-02 |
| PV input & tracking | |
| Independent MPPT trackers | 2Number of MPP trackers Official source ↗ · Technical Data > Input Data Revision: Unknown · Checked 2026-10-02 |
| MPPT operating window minimum | 190 VMPP voltage range Official source ↗ · Technical Data > Input Data Revision: Unknown · Checked 2026-10-02 |
| MPPT operating window maximum | 530 VMPP voltage range Official source ↗ · Technical Data > Input Data Revision: Unknown · Checked 2026-10-02 |
| DC operating voltage minimum | 65 VU_dc min - U_dc max Official source ↗ · Technical Data > Input Data Revision: Unknown · Checked 2026-10-02 |
| DC operating voltage maximum | 600 VU_dc min - U_dc max Official source ↗ · Technical Data > Input Data Revision: Unknown · Checked 2026-10-02 |
| Maximum PV input voltage | 600 VTask23 QC-approved exact-model/market manufacturer specification. Official source ↗ · Technical Data > Input Data Revision: Unknown · Checked 2026-10-02 |
| Maximum input current per tracker/input | MPPT1 22 / MPPT2 12 AMax. input current (I_dc max), manufacturer two-MPPT topology preserved Official source ↗ · Technical Data > Input Data Revision: Unknown · Checked 2026-10-02 |
| Maximum PV short-circuit current | MPPT1 41.25 / MPPT2 22 AMax. short circuit current, module array; exact two-MPPT scope Official source ↗ · Technical Data > Input Data Revision: Unknown · Checked 2026-10-02 |
| Efficiency & environment | |
| Maximum conversion efficiency | 97.6 %Max. efficiency (PV-grid) Official source ↗ · Technical Data > Efficiency Revision: Unknown · Checked 2026-10-02 |
| European efficiency | Unknown |
| Operating ambient temperature minimum | -40 °CAmbient temperature range; no extra derating curve inferred Official source ↗ · Technical Data > General Data Revision: Unknown · Checked 2026-10-02 |
| Operating ambient temperature maximum | 60 °CAmbient temperature range; no extra derating curve inferred Official source ↗ · Technical Data > General Data Revision: Unknown · Checked 2026-10-02 |
| Enclosure protection | IP66Degree of protection Official source ↗ · Technical Data > General Data Revision: Unknown · Checked 2026-10-02 |
| Surge protection | Unknown |
| Warranty | |
| Warranty and eligibility | Unknown |
Comparison category basis
Task23 QC-approved product-family technical context; normalized for catalogue grouping.
Generic artwork is presentation-only and is not hardware, compatibility, dimension or electrical evidence.