PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

Hybrid / smart energy inverter 2 exact records
Edit selection
Inverter electrical comparison
SpecificationX3-HYBRID-10.0-DSolaX Power · PakistanDeep comparison fields reviewedGW100K07-ETCGoodWe Technologies Co., Ltd. · AustraliaDeep comparison fields reviewed
AC output
Rated AC active power10000 WRated output power (on-grid); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
100000 WOn-grid nominal output power; exact source raw value '100 kW' kW. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
Maximum AC apparent output11000 VAMaximum output apparent power (on-grid); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
110000 VAMax apparent power to utility grid; exact source raw value '110 kVA' kVA. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
Connection phases3Pakistan localized official exact product; three-phase unbalanced output and 3-phase AC topology
Official source ↗
3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained.
Official source ↗
PV input & tracking
Independent MPPT trackers2Number of MPP trackers; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
2MPP trackers; exact model/market Task10 evidence reused.
Official source ↗
MPPT operating window minimum180 VMPPT voltage range (not a full-power MPPT range); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
250 VMPPT operating range; endpoint of exact official range [250, 960], not the absolute DC limit.
Official source ↗
MPPT operating window maximum950 VMPPT voltage range (not a full-power MPPT range); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
960 VMPPT operating range; endpoint of exact official range [250, 960], not the absolute DC limit.
Official source ↗
DC operating voltage minimumUnknownUnknown
DC operating voltage maximumUnknownUnknown
Maximum PV input voltage1000 VMaximum PV input voltage; upper DC voltage limit; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
1000 VPV max input voltage; exact model/market Task10 evidence reused.
Official source ↗
Maximum input current per tracker/input28 / 16 AMPPT1/MPPT2 maximum input current; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
100 AMax input current per MPPT; per-MPPT/input maximum, not total inverter current.
Official source ↗
Maximum PV short-circuit current35 / 20 AMPPT1/MPPT2 maximum input short-circuit current; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
125 AMax short circuit current per MPPT; per-MPPT/input maximum, not total inverter current.
Official source ↗
Efficiency & environment
Maximum conversion efficiency98 %Maximum conversion efficiency; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
97.6 %Max efficiency; exact model/market Task10 evidence reused.
Official source ↗
European efficiency97.7 %European efficiency; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
97.3 %European efficiency; exact model/market Task10 evidence reused.
Official source ↗
Operating ambient temperature minimum-35 °COperating ambient temperature range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
-20 °COperating temp; >45°C derating; lower endpoint of exact official range [-20, 60].
Official source ↗
Operating ambient temperature maximum60 °COperating ambient temperature range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
60 °COperating temp; >45°C derating; upper endpoint of exact official range [-20, 60].
Official source ↗
Enclosure protectionIP65Ingress protection; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
IP20Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval.
Official source ↗
Surge protectionUnknownDC: Type II (Type I + II optional); AC: Type II (Type I + II optional)Official surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated.
Official source ↗
Warranty
Warranty and eligibilityUnknownUnknown