Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
| Specification | GW110K-GTGoodWe Technologies Co., Ltd. · Global catalog (country/grid exceptions separated as material variants)Deep comparison fields reviewed | Fronius Symo GEN24 8.0Fronius International GmbH · Europe / ROWDeep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 110000 WNominal output power; exact source raw value '110 kW' kW. Converted exactly to website base unit; W and VA not interchanged. Source unit W Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 8000 W Source unit W Official source ↗ Technical Data > Output Data > AC nominal output Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum AC apparent output | 121000 VAMax AC apparent power; exact source raw value '121 kVA' kVA. Converted exactly to website base unit; W and VA not interchanged. Source unit VA Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 8000 VA Source unit VA Official source ↗ Technical Data > Output Data > Max. output power Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Connection phases | 3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained. Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | three-phase Official source ↗ Technical Data > Output Data > Grid connection Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| PV input & tracking | ||
| Independent MPPT trackers | 10MPP trackers; exact model/market Task10 evidence reused. Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 2 Official source ↗ Technical Data > Input Data > Number of MPP trackers Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window minimum | 180 VMPPT operating range; endpoint of exact official range [180, 1000], not the absolute DC limit. Source unit V Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 80 VReviewed MPPT/usable MPP operating window minimum Source unit V Official source ↗ Technical Data > Input Data > Usable MPP voltage range Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window maximum | 1000 VMPPT operating range; endpoint of exact official range [180, 1000], not the absolute DC limit. Source unit V Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 800 VReviewed MPPT/usable MPP operating window maximum Source unit V Official source ↗ Technical Data > Input Data > Usable MPP voltage range Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| DC operating voltage minimum | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown |
| Maximum PV input voltage | 1100 VMax input voltage; exact model/market Task10 evidence reused. Source unit V Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 1000 V Source unit V Official source ↗ Technical data > Fronius Symo GEN24 8.0/8.0 Plus > DC input data > Maximum input voltage Revision 4204260315 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum input current per tracker/input | 42 AMax input current per MPPT; per-MPPT/input maximum, not total inverter current. Source unit A Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | MPPT1 25 / MPPT2 12.5 A Source unit A Official source ↗ Technical data > Fronius Symo GEN24 8.0/8.0 Plus > DC input data > Maximum input current Revision 4204260315 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum PV short-circuit current | 52.5 AMax short circuit current per MPPT; per-MPPT/input maximum, not total inverter current. Source unit A Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | MPPT1 40 / MPPT2 20 A Source unit A Official source ↗ Technical data > Fronius Symo GEN24 8.0/8.0 Plus > DC input data > Maximum short circuit current for module array Revision 4204260315 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Efficiency & environment | ||
| Maximum conversion efficiency | 98.8 %Max efficiency; exact model/market Task10 evidence reused. Source unit % Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 98.2 % Source unit % Official source ↗ Technical Data > Efficiency > Max. efficiency (PV - grid) Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| European efficiency | 98.4 %European efficiency; exact model/market Task10 evidence reused. Source unit % Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | Unknown |
| Operating ambient temperature minimum | -30 °COperating temp; lower endpoint of exact official range [-30, 60]. Source unit °C Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | -25 °COperating ambient temperature minimum Source unit °C Official source ↗ Technical Data > General Data > Ambient temperature range Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Operating ambient temperature maximum | 60 °COperating temp; upper endpoint of exact official range [-30, 60]. Source unit °C Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 60 °COperating ambient temperature maximum Source unit °C Official source ↗ Technical Data > General Data > Ambient temperature range Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Enclosure protection | IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval. Official source ↗ Official technical data / Ingress Protection Rating; exact family/model applicability for GW110K-GT. Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | IP66 Official source ↗ Technical Data > General Data > Degree of protection Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Surge protection | DC: Type II (Type I + II optional where stated); AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ Official Protection table / surge-protection rows for family containing exact model GW110K-GT. Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | Unknown |
| Warranty | ||
| Warranty and eligibility | Unknown | Unknown |