GoodWe Technologies Co., Ltd.
GoodWe Technologies Co., Ltd. GW110K-GT
GT Series 100-125kW
String inverter
GoodWe Technologies Co., Ltd. GW110K-GT has a reviewed nominal AC active-power rating of 110000 W.
Deep comparison fields reviewedThis local comparison record does not approve module compatibility, string sizing, grid connection or electrical safety.
Documented source scope: Global catalog (country/grid exceptions separated as material variants). This is not a statement about your location or product availability. Exact canonical market retained: Global catalog (country/grid exceptions separated as material variants). Material variant retained: 'standard'. Catalogue evidence only; compatibility, string sizing, grid approval, design approval, safety approval and live publication remain false.
Representative illustration — not the manufacturer’s exact hardware appearance.
Field-level provenance
Electrical specifications
Unknown means the field has not passed this exact-record integration review. It does not mean zero.
| AC output | |
|---|---|
| Rated AC active power | 110000 WNominal output power; exact source raw value '110 kW' kW. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ · Technical Data table Revision: GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 |
| Maximum AC apparent output | 121000 VAMax AC apparent power; exact source raw value '121 kVA' kVA. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ · Technical Data table Revision: GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 |
| Connection phases | 3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained. Official source ↗ · Technical Data table Revision: GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 |
| PV input & tracking | |
| Independent MPPT trackers | 10MPP trackers; exact model/market Task10 evidence reused. Official source ↗ · Technical Data table Revision: GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 |
| MPPT operating window minimum | 180 VMPPT operating range; endpoint of exact official range [180, 1000], not the absolute DC limit. Official source ↗ · Technical Data table Revision: GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 |
| MPPT operating window maximum | 1000 VMPPT operating range; endpoint of exact official range [180, 1000], not the absolute DC limit. Official source ↗ · Technical Data table Revision: GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 |
| DC operating voltage minimum | Unknown |
| DC operating voltage maximum | Unknown |
| Maximum PV input voltage | 1100 VMax input voltage; exact model/market Task10 evidence reused. Official source ↗ · Technical Data table Revision: GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 |
| Maximum input current per tracker/input | 42 AMax input current per MPPT; per-MPPT/input maximum, not total inverter current. Official source ↗ · Technical Data table Revision: GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 |
| Maximum PV short-circuit current | 52.5 AMax short circuit current per MPPT; per-MPPT/input maximum, not total inverter current. Official source ↗ · Technical Data table Revision: GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 |
| Efficiency & environment | |
| Maximum conversion efficiency | 98.8 %Max efficiency; exact model/market Task10 evidence reused. Official source ↗ · Technical Data table Revision: GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 |
| European efficiency | 98.4 %European efficiency; exact model/market Task10 evidence reused. Official source ↗ · Technical Data table Revision: GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 |
| Operating ambient temperature minimum | -30 °COperating temp; lower endpoint of exact official range [-30, 60]. Official source ↗ · Technical Data table Revision: GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 |
| Operating ambient temperature maximum | 60 °COperating temp; upper endpoint of exact official range [-30, 60]. Official source ↗ · Technical Data table Revision: GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 |
| Enclosure protection | IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval. Official source ↗ · Official technical data / Ingress Protection Rating; exact family/model applicability for GW110K-GT. Revision: GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 |
| Surge protection | DC: Type II (Type I + II optional where stated); AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ · Official Protection table / surge-protection rows for family containing exact model GW110K-GT. Revision: GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 |
| Warranty | |
| Warranty and eligibility | Unknown |
Comparison category basis
Task10 official exact-model evidence classifies the source family as C&I string inverter; retained as string comparison category.
Generic artwork is presentation-only and is not hardware, compatibility, dimension or electrical evidence.