PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

String inverter 2 exact records · Differences include rating conditions and scope.
Edit selection
Inverter electrical comparison
SpecificationGW110K-GTGoodWe Technologies Co., Ltd. · Global catalog (country/grid exceptions separated as material variants)Deep comparison fields reviewedV36Fox ESS · Global / ROW official siteDeep comparison fields reviewed
AC output
Rated AC active power110000 WNominal output power; exact source raw value '110 kW' kW. Converted exactly to website base unit; W and VA not interchanged.
Source unit W
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

36000 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit W
Official source ↗
technical table Nominal Output Active Power
Revision V2.3 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum AC apparent output121000 VAMax AC apparent power; exact source raw value '121 kVA' kVA. Converted exactly to website base unit; W and VA not interchanged.
Source unit VA
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

39600 VAmaximum apparent AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit VA
Official source ↗
technical table Max. Output Apparent Power
Revision V2.3 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Connection phases3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained.
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
p.2 AC OUTPUT — Nominal AC Grid Voltage 380/400 V, 3W+N+PE; exact model column
Revision V2.3 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

PV input & tracking
Independent MPPT trackers10MPP trackers; exact model/market Task10 evidence reused.
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

4independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
technical table No. of MPP Trackers
Revision V2.3 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT operating window minimum180 VMPPT operating range; endpoint of exact official range [180, 1000], not the absolute DC limit.
Source unit V
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

200 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit V
Official source ↗
technical table MPPT Operating Voltage Range; canonical min bound from source range
Revision V2.3 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT operating window maximum1000 VMPPT operating range; endpoint of exact official range [180, 1000], not the absolute DC limit.
Source unit V
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

1000 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit V
Official source ↗
technical table MPPT Operating Voltage Range; canonical max bound from source range
Revision V2.3 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

DC operating voltage minimumUnknownUnknown
DC operating voltage maximumUnknownUnknown
Maximum PV input voltage1100 VMax input voltage; exact model/market Task10 evidence reused.
Source unit V
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

1100 Vmaximum DC input voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit V
Official source ↗
technical table Max. Input Voltage
Revision V2.3 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum input current per tracker/input42 AMax input current per MPPT; per-MPPT/input maximum, not total inverter current.
Source unit A
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

40 Amaximum current per MPPT; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit A
Official source ↗
technical table Max. Input Current
Revision V2.3 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum PV short-circuit current52.5 AMax short circuit current per MPPT; per-MPPT/input maximum, not total inverter current.
Source unit A
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

50 Amaximum short-circuit current per MPPT; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit A
Official source ↗
technical table Max. Short-circuit Current
Revision V2.3 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Efficiency & environment
Maximum conversion efficiency98.8 %Max efficiency; exact model/market Task10 evidence reused.
Source unit %
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

98.7 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit %
Official source ↗
technical table Max. Efficiency
Revision V2.3 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

European efficiency98.4 %European efficiency; exact model/market Task10 evidence reused.
Source unit %
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

98.4 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit %
Official source ↗
technical table European Efficiency
Revision V2.3 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Operating ambient temperature minimum-30 °COperating temp; lower endpoint of exact official range [-30, 60].
Source unit °C
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

-30 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit °C
Official source ↗
technical table Operating Temperature; canonical min bound from source range
Revision V2.3 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Operating ambient temperature maximum60 °COperating temp; upper endpoint of exact official range [-30, 60].
Source unit °C
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

60 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit °C
Official source ↗
technical table Operating Temperature; canonical max bound from source range
Revision V2.3 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Enclosure protectionIP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval.
Official source ↗
Official technical data / Ingress Protection Rating; exact family/model applicability for GW110K-GT.
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

IP66ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
technical table Ingress Protection Rating
Revision V2.3 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Surge protectionDC: Type II (Type I + II optional where stated); AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated.
Official source ↗
Official Protection table / surge-protection rows for family containing exact model GW110K-GT.
Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
p.2 PROTECTION — Surge Protection DC Type II / AC Type II
Revision V2.3 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Warranty
Warranty and eligibilityUnknownUnknown