Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
| Specification | GW110K-GTGoodWe Technologies Co., Ltd. · Global catalog (country/grid exceptions separated as material variants)Deep comparison fields reviewed | V36Fox ESS · Global / ROW official siteDeep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 110000 WNominal output power; exact source raw value '110 kW' kW. Converted exactly to website base unit; W and VA not interchanged. Source unit W Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 36000 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit W Official source ↗ technical table Nominal Output Active Power Revision V2.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum AC apparent output | 121000 VAMax AC apparent power; exact source raw value '121 kVA' kVA. Converted exactly to website base unit; W and VA not interchanged. Source unit VA Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 39600 VAmaximum apparent AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit VA Official source ↗ technical table Max. Output Apparent Power Revision V2.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Connection phases | 3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained. Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference. Official source ↗ p.2 AC OUTPUT — Nominal AC Grid Voltage 380/400 V, 3W+N+PE; exact model column Revision V2.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| PV input & tracking | ||
| Independent MPPT trackers | 10MPP trackers; exact model/market Task10 evidence reused. Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 4independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ technical table No. of MPP Trackers Revision V2.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window minimum | 180 VMPPT operating range; endpoint of exact official range [180, 1000], not the absolute DC limit. Source unit V Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 200 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit V Official source ↗ technical table MPPT Operating Voltage Range; canonical min bound from source range Revision V2.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window maximum | 1000 VMPPT operating range; endpoint of exact official range [180, 1000], not the absolute DC limit. Source unit V Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 1000 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit V Official source ↗ technical table MPPT Operating Voltage Range; canonical max bound from source range Revision V2.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| DC operating voltage minimum | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown |
| Maximum PV input voltage | 1100 VMax input voltage; exact model/market Task10 evidence reused. Source unit V Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 1100 Vmaximum DC input voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit V Official source ↗ technical table Max. Input Voltage Revision V2.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum input current per tracker/input | 42 AMax input current per MPPT; per-MPPT/input maximum, not total inverter current. Source unit A Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 40 Amaximum current per MPPT; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit A Official source ↗ technical table Max. Input Current Revision V2.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum PV short-circuit current | 52.5 AMax short circuit current per MPPT; per-MPPT/input maximum, not total inverter current. Source unit A Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 50 Amaximum short-circuit current per MPPT; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit A Official source ↗ technical table Max. Short-circuit Current Revision V2.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Efficiency & environment | ||
| Maximum conversion efficiency | 98.8 %Max efficiency; exact model/market Task10 evidence reused. Source unit % Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 98.7 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit % Official source ↗ technical table Max. Efficiency Revision V2.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| European efficiency | 98.4 %European efficiency; exact model/market Task10 evidence reused. Source unit % Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 98.4 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit % Official source ↗ technical table European Efficiency Revision V2.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Operating ambient temperature minimum | -30 °COperating temp; lower endpoint of exact official range [-30, 60]. Source unit °C Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | -30 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit °C Official source ↗ technical table Operating Temperature; canonical min bound from source range Revision V2.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Operating ambient temperature maximum | 60 °COperating temp; upper endpoint of exact official range [-30, 60]. Source unit °C Official source ↗ Technical Data table Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 60 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit °C Official source ↗ technical table Operating Temperature; canonical max bound from source range Revision V2.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Enclosure protection | IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval. Official source ↗ Official technical data / Ingress Protection Rating; exact family/model applicability for GW110K-GT. Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | IP66ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ technical table Ingress Protection Rating Revision V2.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Surge protection | DC: Type II (Type I + II optional where stated); AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ Official Protection table / surge-protection rows for family containing exact model GW110K-GT. Revision GoodWe-Single page-20260107-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval. Official source ↗ p.2 PROTECTION — Surge Protection DC Type II / AC Type II Revision V2.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Warranty | ||
| Warranty and eligibility | Unknown | Unknown |