Hybrid / smart energy inverter
2 exact records
Edit selection
| Specification | SPH 5000TL BL-UPGrowatt New Energy · Global / ROWDeep comparison fields reviewed | GW10K-ES-C10GoodWe Technologies Co., Ltd. · Global / ROW (GoodWe global site; regional footnotes retained)Deep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 5000 Wnominal AC output power Official source ↗ | 10000 Wnominal/rated active power; exact source raw value '10.0' kW. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ |
| Maximum AC apparent output | 5000 VAmaximum AC apparent power Official source ↗ | 11000 VAmaximum apparent power; exact source raw value '11.0' kVA. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ |
| Connection phases | single_phaseExact model/market phase classification retained from Task10 source-worker review; no cross-model interpolation. Official source ↗ | 1Connection phase count bound to Task10 exact identity (Single phase); nominal wiring/voltage evidence retained. Official source ↗ |
| PV input & tracking | ||
| Independent MPPT trackers | 2independent MPP trackers Official source ↗ | 2count; exact model/market Task10 evidence reused. Official source ↗ |
| MPPT operating window minimum | 120 VMPPT operating voltage range Official source ↗ | 60 Voperating range; endpoint of exact official range [60, 550], not the absolute DC limit. Official source ↗ |
| MPPT operating window maximum | 550 VMPPT operating voltage range Official source ↗ | 550 Voperating range; endpoint of exact official range [60, 550], not the absolute DC limit. Official source ↗ |
| DC operating voltage minimum | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown |
| Maximum PV input voltage | 550 VPV maximum input voltage Official source ↗ | 600 Vmaximum; exact model/market Task10 evidence reused. Official source ↗ |
| Maximum input current per tracker/input | 13.5 Amaximum PV input current per MPPT Official source ↗ | 32 Aper-MPPT maximum; exact per-MPPT sequence [32, 32]; scalar stores the maximum listed per-MPPT value, not a sum. Official source ↗ |
| Maximum PV short-circuit current | 16.9 Amaximum PV short-circuit current per MPPT Official source ↗ | 48 Aper-MPPT maximum; exact per-MPPT sequence [48, 48]; scalar stores the maximum listed per-MPPT value, not a sum. Official source ↗ |
| Efficiency & environment | ||
| Maximum conversion efficiency | 97.5 %maximum efficiency Official source ↗ | 97.6 %maximum efficiency; exact model/market Task10 evidence reused. Official source ↗ |
| European efficiency | Unknown | 96.2 %European efficiency; exact model/market Task10 evidence reused. Official source ↗ |
| Operating ambient temperature minimum | -25 °Coperating ambient range Official source ↗ | -35 °Coperating range; lower endpoint of exact official range [-35, 60]. Official source ↗ |
| Operating ambient temperature maximum | 60 °Coperating ambient range Official source ↗ | 60 °Coperating range; upper endpoint of exact official range [-35, 60]. Official source ↗ |
| Enclosure protection | IP65enclosure ingress protection Official source ↗ | IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval. Official source ↗ |
| Surge protection | Unknown | DC: Type III; AC: Type IIIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ |
| Warranty | ||
| Warranty and eligibility | 5 / 10Manufacturer warranty statement/options as published; eligibility and local terms may vary and are not independently granted by this catalogue review. QC schema normalization: canonical display-field unit is ''; original Task18 unit metadata was 'years'. The value semantics are preserved in the field value/test condition. Official source ↗ | Unknown |