GoodWe Technologies Co., Ltd.
GoodWe Technologies Co., Ltd. GW10K-ES-C10
ES Uniq
Hybrid / smart energy inverter
GoodWe Technologies Co., Ltd. GW10K-ES-C10 has a reviewed nominal AC active-power rating of 10000 W.
Deep comparison fields reviewedThis local comparison record does not approve module compatibility, string sizing, grid connection or electrical safety.
Documented source scope: Global / ROW (GoodWe global site; regional footnotes retained). This is not a statement about your location or product availability. Exact canonical market retained: Global / ROW (GoodWe global site; regional footnotes retained). Material variant retained: None. Catalogue evidence only; compatibility, string sizing, grid approval, design approval, safety approval and live publication remain false.
Representative illustration — not the manufacturer’s exact hardware appearance.
Field-level provenance
Electrical specifications
Unknown means the field has not passed this exact-record integration review. It does not mean zero.
| AC output | |
|---|---|
| Rated AC active power | 10000 Wnominal/rated active power; exact source raw value '10.0' kW. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ · Technical Data > AC nominal/rated output power Revision: GoodWe-Single page-20260507-EN-V2.1 · Checked 2026-10-02 |
| Maximum AC apparent output | 11000 VAmaximum apparent power; exact source raw value '11.0' kVA. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ · Technical Data > Max. apparent power to utility grid Revision: GoodWe-Single page-20260507-EN-V2.1 · Checked 2026-10-02 |
| Connection phases | 1Connection phase count bound to Task10 exact identity (Single phase); nominal wiring/voltage evidence retained. Official source ↗ · Technical Data > Nominal output voltage Revision: GoodWe-Single page-20260507-EN-V2.1 · Checked 2026-10-02 |
| PV input & tracking | |
| Independent MPPT trackers | 2count; exact model/market Task10 evidence reused. Official source ↗ · Technical Data > Number of MPPT trackers Revision: GoodWe-Single page-20260507-EN-V2.1 · Checked 2026-10-02 |
| MPPT operating window minimum | 60 Voperating range; endpoint of exact official range [60, 550], not the absolute DC limit. Official source ↗ · Technical Data > MPPT operating voltage range Revision: GoodWe-Single page-20260507-EN-V2.1 · Checked 2026-10-02 |
| MPPT operating window maximum | 550 Voperating range; endpoint of exact official range [60, 550], not the absolute DC limit. Official source ↗ · Technical Data > MPPT operating voltage range Revision: GoodWe-Single page-20260507-EN-V2.1 · Checked 2026-10-02 |
| DC operating voltage minimum | Unknown |
| DC operating voltage maximum | Unknown |
| Maximum PV input voltage | 600 Vmaximum; exact model/market Task10 evidence reused. Official source ↗ · Technical Data > PV max. input voltage Revision: GoodWe-Single page-20260507-EN-V2.1 · Checked 2026-10-02 |
| Maximum input current per tracker/input | 32 Aper-MPPT maximum; exact per-MPPT sequence [32, 32]; scalar stores the maximum listed per-MPPT value, not a sum. Official source ↗ · Technical Data > Max. input current per MPPT Revision: GoodWe-Single page-20260507-EN-V2.1 · Checked 2026-10-02 |
| Maximum PV short-circuit current | 48 Aper-MPPT maximum; exact per-MPPT sequence [48, 48]; scalar stores the maximum listed per-MPPT value, not a sum. Official source ↗ · Technical Data > Max. short-circuit current per MPPT Revision: GoodWe-Single page-20260507-EN-V2.1 · Checked 2026-10-02 |
| Efficiency & environment | |
| Maximum conversion efficiency | 97.6 %maximum efficiency; exact model/market Task10 evidence reused. Official source ↗ · Technical Data > Max. efficiency Revision: GoodWe-Single page-20260507-EN-V2.1 · Checked 2026-10-02 |
| European efficiency | 96.2 %European efficiency; exact model/market Task10 evidence reused. Official source ↗ · Technical Data > European efficiency Revision: GoodWe-Single page-20260507-EN-V2.1 · Checked 2026-10-02 |
| Operating ambient temperature minimum | -35 °Coperating range; lower endpoint of exact official range [-35, 60]. Official source ↗ · Technical Data > Operating temperature range Revision: GoodWe-Single page-20260507-EN-V2.1 · Checked 2026-10-02 |
| Operating ambient temperature maximum | 60 °Coperating range; upper endpoint of exact official range [-35, 60]. Official source ↗ · Technical Data > Operating temperature range Revision: GoodWe-Single page-20260507-EN-V2.1 · Checked 2026-10-02 |
| Enclosure protection | IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval. Official source ↗ · Official technical data / Ingress Protection Rating; exact family/model applicability for GW10K-ES-C10. Revision: GoodWe-Single page-20260507-EN-V2.1 · Checked 2026-10-02 |
| Surge protection | DC: Type III; AC: Type IIIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ · Official Protection table / surge-protection rows for family containing exact model GW10K-ES-C10. Revision: GoodWe-Single page-20260507-EN-V2.1 · Checked 2026-10-02 |
| Warranty | |
| Warranty and eligibility | Unknown |
Comparison category basis
Task10 official exact-model evidence classifies the source family as Residential hybrid inverter (LV); retained as hybrid comparison category.
Generic artwork is presentation-only and is not hardware, compatibility, dimension or electrical evidence.