APsystems
APsystems DS3-L
DS3 Series
Microinverter
Deep comparison fields reviewedThis local comparison record does not approve module compatibility, string sizing, grid connection or electrical safety.
Documented source scope: Philippines. This is not a statement about your location or product availability. Canonical exact market retained. Only reviewed manufacturer fields are exposed; country certification and compatibility are not approved.
Representative illustration — not the manufacturer’s exact hardware appearance.
Field-level provenance
Electrical specifications
Unknown means the field has not passed this exact-record integration review. It does not mean zero.
| AC output | |
|---|---|
| Rated AC active power | Unknown |
| Maximum AC apparent output | 730 VAMaximum continuous apparent output in VA; no W nameplate inferred. Official source ↗ · PDF page 2, DS3-L column 1, ac_max_va row; retain associated footnotes Revision: Rev1.3 · Checked 2026-10-02 |
| Connection phases | Unknown |
| PV input & tracking | |
| Independent MPPT trackers | 2Manufacturer rated specification for this exact model and market; no compatibility approval. Official source ↗ · PDF page 1, DS3-L column 1, mppt_count row; retain associated footnotes Revision: Rev1.3 · Checked 2026-10-02 |
| MPPT operating window minimum | 28 VManufacturer rated specification for this exact model and market; no compatibility approval. Official source ↗ · PDF page 2, DS3-L column 1, mppt_min_v row; retain associated footnotes Revision: Rev1.3 · Checked 2026-10-02 |
| MPPT operating window maximum | 45 VManufacturer rated specification for this exact model and market; no compatibility approval. Official source ↗ · PDF page 2, DS3-L column 1, mppt_max_v row; retain associated footnotes Revision: Rev1.3 · Checked 2026-10-02 |
| DC operating voltage minimum | Unknown |
| DC operating voltage maximum | Unknown |
| Maximum PV input voltage | 60 VManufacturer rated specification for this exact model and market; no compatibility approval. Official source ↗ · PDF page 2, DS3-L column 1, max_dc_v row; retain associated footnotes Revision: Rev1.3 · Checked 2026-10-02 |
| Maximum input current per tracker/input | 18 APer input, two independent MPPT channels. Official source ↗ · PDF page 2, DS3-L column 1, input_current_a row; retain associated footnotes Revision: Rev1.3 · Checked 2026-10-02 |
| Maximum PV short-circuit current | 22.5 APer DC input. Official source ↗ · PDF page 2, DS3-L column 1, short_circuit_a row; retain associated footnotes Revision: Rev1.3 · Checked 2026-10-02 |
| Efficiency & environment | |
| Maximum conversion efficiency | 97 %Manufacturer rated specification for this exact model and market; no compatibility approval. Official source ↗ · PDF page 2, DS3-L column 1, max_efficiency row; retain associated footnotes Revision: Rev1.3 · Checked 2026-10-02 |
| European efficiency | Unknown |
| Operating ambient temperature minimum | -40 °CManufacturer rated specification for this exact model and market; no compatibility approval. Official source ↗ · PDF page 2, DS3-L column 1, operating_min_c row; retain associated footnotes Revision: Rev1.3 · Checked 2026-10-02 |
| Operating ambient temperature maximum | 65 °CManufacturer may derate under poor DC power input or poor ventilation/heat dissipation. Official source ↗ · PDF page 2, DS3-L column 1, operating_max_c row; retain associated footnotes Revision: Rev1.3 · Checked 2026-10-02 |
| Enclosure protection | Type 6Manufacturer rated specification for this exact model and market; no compatibility approval. Official source ↗ · PDF page 2, DS3-L column 1, protection row; retain associated footnotes Revision: Rev1.3 · Checked 2026-10-02 |
| Surge protection | Unknown |
| Warranty | |
| Warranty and eligibility | 12 years standard, subject to manufacturer terms; EMA portal monitoring required for warranty eligibility.Manufacturer rated specification for this exact model and market; no compatibility approval. Official source ↗ · PDF page 2, DS3-L column 1, warranty row; retain associated footnotes Revision: Rev1.3 · Checked 2026-10-02 |
Comparison category basis
Official evidence identifies DS3/QT2 as microinverters.
Generic artwork is presentation-only and is not hardware, compatibility, dimension or electrical evidence.