Growatt New Energy
Growatt New Energy MID 15KTL3-X
MID 15-25KTL3-X
String inverter
Growatt New Energy MID 15KTL3-X has a reviewed nominal AC active-power rating of 15000 W.
Deep comparison fields reviewedThis local comparison record does not approve module compatibility, string sizing, grid connection or electrical safety.
Representative illustration — not the manufacturer’s exact hardware appearance.
Field-level provenance
Electrical specifications
Unknown means the field has not passed this exact-record integration review. It does not mean zero.
| AC output | |
|---|---|
| Rated AC active power | 15000 Wmanufacturer datasheet table row as labelled; no design inference Official source ↗ · Output data (AC): Rated/AC nominal power Revision: 2026.5 Update · Checked 2026-10-02 |
| Maximum AC apparent output | 16600 VAmanufacturer datasheet table row as labelled; no design inference Official source ↗ · Output data (AC): Max. AC apparent power Revision: 2026.5 Update · Checked 2026-10-02 |
| Connection phases | three_phaseExact model/market phase classification retained from Task10 source-worker review; no cross-model interpolation. Official source ↗ · Task10 exact-model canonical record: phase=three_phase; official manufacturer family/product evidence retained in provenance_refs. Revision: live official HTML snapshot; publisher revision not displayed; accessed 2026-10-02 · Checked 2026-10-02 |
| PV input & tracking | |
| Independent MPPT trackers | 2manufacturer datasheet table row as labelled; no design inference Official source ↗ · Input data (DC): No. of MPP trackers Revision: 2026.5 Update · Checked 2026-10-02 |
| MPPT operating window minimum | 200 Vmanufacturer datasheet table row as labelled; no design inference Official source ↗ · Input data (DC): MPP/MPPT voltage range Revision: 2026.5 Update · Checked 2026-10-02 |
| MPPT operating window maximum | 1000 Vmanufacturer datasheet table row as labelled; no design inference Official source ↗ · Input data (DC): MPP/MPPT voltage range Revision: 2026.5 Update · Checked 2026-10-02 |
| DC operating voltage minimum | Unknown |
| DC operating voltage maximum | Unknown |
| Maximum PV input voltage | 1100 Vmanufacturer datasheet table row as labelled; no design inference Official source ↗ · Input data (DC): Max. DC voltage Revision: 2026.5 Update · Checked 2026-10-02 |
| Maximum input current per tracker/input | 27 Amanufacturer datasheet table row as labelled; no design inference Official source ↗ · Input data (DC): Max. input current per MPP tracker Revision: 2026.5 Update · Checked 2026-10-02 |
| Maximum PV short-circuit current | 33.8 Amanufacturer datasheet table row as labelled; no design inference Official source ↗ · Input data (DC): Max. short-circuit current per MPP tracker Revision: 2026.5 Update · Checked 2026-10-02 |
| Efficiency & environment | |
| Maximum conversion efficiency | 98.75 %manufacturer datasheet table row as labelled; no design inference Official source ↗ · Efficiency: Max. efficiency Revision: 2026.5 Update · Checked 2026-10-02 |
| European efficiency | 98.6 %manufacturer datasheet table row as labelled; no design inference Official source ↗ · Efficiency: European efficiency Revision: 2026.5 Update · Checked 2026-10-02 |
| Operating ambient temperature minimum | -25 °Cmanufacturer datasheet table row as labelled; no design inference Official source ↗ · General data: Operating temperature range Revision: 2026.5 Update · Checked 2026-10-02 |
| Operating ambient temperature maximum | 60 °Cmanufacturer datasheet table row as labelled; no design inference Official source ↗ · General data: Operating temperature range Revision: 2026.5 Update · Checked 2026-10-02 |
| Enclosure protection | IP65manufacturer datasheet table row as labelled; no design inference Official source ↗ · General data: Protection degree Revision: 2026.5 Update · Checked 2026-10-02 |
| Surge protection | Unknown |
| Warranty | |
| Warranty and eligibility | standard 5 / optional 10Manufacturer warranty statement/options as published; eligibility and local terms may vary and are not independently granted by this catalogue review. QC schema normalization: canonical display-field unit is ''; original Task18 unit metadata was 'years'. The value semantics are preserved in the field value/test condition. Official source ↗ · General data: Warranty Revision: 2026.5 Update · Checked 2026-10-02 |
Comparison category basis
Task10 exact-model category 'Commercial & Industrial PV Inverter' normalized conservatively to 'string'. AC-coupled storage remains 'unknown' rather than being forced into PV-string/hybrid comparison gates.
Generic artwork is presentation-only and is not hardware, compatibility, dimension or electrical evidence.