Growatt New Energy
Growatt New Energy WIT 22K-HU
WIT 4-25K-HU
Hybrid / smart energy inverter
Growatt New Energy WIT 22K-HU has a reviewed nominal AC active-power rating of 22000 W.
Deep comparison fields reviewedThis local comparison record does not approve module compatibility, string sizing, grid connection or electrical safety.
Representative illustration — not the manufacturer’s exact hardware appearance.
Field-level provenance
Electrical specifications
Unknown means the field has not passed this exact-record integration review. It does not mean zero.
| AC output | |
|---|---|
| Rated AC active power | 22000 Wrated AC active output power Official source ↗ · PDF p.2, exact model column 'WIT 22K-HU', row 'Rated AC output power' Revision: 202605 · Checked 2026-10-02 |
| Maximum AC apparent output | 24200 VAmaximum AC apparent power Official source ↗ · PDF p.2, exact model column 'WIT 22K-HU', row 'Max. apparent power' Revision: 202605 · Checked 2026-10-02 |
| Connection phases | three_phaseExact model/market phase classification retained from Task10 source-worker review; no cross-model interpolation. Official source ↗ · Task10 exact-model canonical record: phase=three-phase; official manufacturer family/product evidence retained in provenance_refs. Revision: current page accessed 2026-10-02 · Checked 2026-10-02 |
| PV input & tracking | |
| Independent MPPT trackers | 2MPP tracker count as published for 17–25 kW table Official source ↗ · PDF p.2, exact model column 'WIT 22K-HU', row 'No. of MPP trackers' Revision: 202605 · Checked 2026-10-02 |
| MPPT operating window minimum | 150 VMPPT operating voltage range Official source ↗ · PDF p.2, exact model column 'WIT 22K-HU', row 'MPP voltage range' Revision: 202605 · Checked 2026-10-02 |
| MPPT operating window maximum | 850 VMPPT operating voltage range Official source ↗ · PDF p.2, exact model column 'WIT 22K-HU', row 'MPP voltage range' Revision: 202605 · Checked 2026-10-02 |
| DC operating voltage minimum | Unknown |
| DC operating voltage maximum | Unknown |
| Maximum PV input voltage | 1000 Vmaximum PV input voltage Official source ↗ · PDF p.2, exact model column 'WIT 22K-HU', row 'Max. input voltage' Revision: 202605 · Checked 2026-10-02 |
| Maximum input current per tracker/input | 40 Amaximum PV input current per MPPT Official source ↗ · PDF p.2, exact model column 'WIT 22K-HU', row 'Max. input current per MPP tracker' Revision: 202605 · Checked 2026-10-02 |
| Maximum PV short-circuit current | 50 Amaximum PV short-circuit current per MPPT Official source ↗ · PDF p.2, exact model column 'WIT 22K-HU', row 'Max. short-circuit current per MPP tracker' Revision: 202605 · Checked 2026-10-02 |
| Efficiency & environment | |
| Maximum conversion efficiency | 97.6 %maximum efficiency Official source ↗ · PDF p.2, exact model column 'WIT 22K-HU', row 'Max. efficiency' Revision: 202605 · Checked 2026-10-02 |
| European efficiency | Unknown |
| Operating ambient temperature minimum | -30 °Coperating ambient range Official source ↗ · PDF p.2, exact model column 'WIT 22K-HU', row 'Operating temperature range' Revision: 202605 · Checked 2026-10-02 |
| Operating ambient temperature maximum | 60 °Coperating ambient range Official source ↗ · PDF p.2, exact model column 'WIT 22K-HU', row 'Operating temperature range' Revision: 202605 · Checked 2026-10-02 |
| Enclosure protection | IP66enclosure ingress protection Official source ↗ · PDF p.2, exact model column 'WIT 22K-HU', row 'Protection degree' Revision: 202605 · Checked 2026-10-02 |
| Surge protection | Unknown |
| Warranty | |
| Warranty and eligibility | 5 / 10Manufacturer warranty statement/options as published; eligibility and local terms may vary and are not independently granted by this catalogue review. QC schema normalization: canonical display-field unit is ''; original Task18 unit metadata was 'years'. The value semantics are preserved in the field value/test condition. Official source ↗ · PDF p.2, exact model column 'WIT 22K-HU', row 'Warranty' Revision: 202605 · Checked 2026-10-02 |
Comparison category basis
Task10 exact-model category 'residential hybrid/storage inverter' normalized conservatively to 'hybrid'. AC-coupled storage remains 'unknown' rather than being forced into PV-string/hybrid comparison gates.
Generic artwork is presentation-only and is not hardware, compatibility, dimension or electrical evidence.