PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← All inverters

Growatt New Energy

Growatt New Energy MIC 600TL-X2

MIC 600-3300TL-X2

String inverter

Growatt New Energy MIC 600TL-X2 has a reviewed nominal AC active-power rating of 600 W.

Deep comparison fields reviewed

This local comparison record does not approve module compatibility, string sizing, grid connection or electrical safety.

Documented source scope: Germany. This is not a statement about your location or product availability.

Official model/market source ↗

Choose an inverter to compare →

Generic representative string inverter illustration

Representative illustration — not the manufacturer’s exact hardware appearance.

Field-level provenance

Electrical specifications

16/18 display fields reviewed

Unknown means the field has not passed this exact-record integration review. It does not mean zero.

MIC 600TL-X2 specifications
AC output
Rated AC active power600 Wrated/nominal AC active output power Raw/footnote context: 600W
Official source ↗ · Datasheet specification table row 'rated_ac_output_w', exact-model column 'MIC 600TL-X2'
Revision: 2026.5 Update · Checked 2026-10-02
Maximum AC apparent output600 VAmaximum AC apparent output power Raw/footnote context: 600VA
Official source ↗ · Datasheet specification table row 'max_ac_apparent_power_va', exact-model column 'MIC 600TL-X2'
Revision: 2026.5 Update · Checked 2026-10-02
Connection phases1Task10 exact-model evidence records phase as 'Single phase'; normalized to 1 connection phase(s). Identity/category source is official Growatt evidence; no grid approval inferred. Raw/footnote context: Type III
Official source ↗ · Task10 exact-model record invmfr_growatt|MIC 600TL-X2|Germany field 'phase'; official identity anchor: Datasheet specification table row 'ac_surge_protection', exact-model column 'MIC 600TL-X2'; source is bound to exact-model record MIC 600TL-X2.
Revision: 2026.5 Update · Checked 2026-10-02
PV input & tracking
Independent MPPT trackers1independent MPP tracker count Raw/footnote context: 1
Official source ↗ · Datasheet specification table row 'mppt_count', exact-model column 'MIC 600TL-X2'
Revision: 2026.5 Update · Checked 2026-10-02
MPPT operating window minimum50 VMPPT operating voltage range; not full-power range unless explicitly stated; lower bound of the manufacturer MPPT operating range. Raw/footnote context: 50-500V
Official source ↗ · Datasheet specification table row 'mppt_operating_range_v', exact-model column 'MIC 600TL-X2'
Revision: 2026.5 Update · Checked 2026-10-02
MPPT operating window maximum500 VMPPT operating voltage range; not full-power range unless explicitly stated; upper bound of the manufacturer MPPT operating range. Raw/footnote context: 50-500V
Official source ↗ · Datasheet specification table row 'mppt_operating_range_v', exact-model column 'MIC 600TL-X2'
Revision: 2026.5 Update · Checked 2026-10-02
DC operating voltage minimumUnknown
DC operating voltage maximumUnknown
Maximum PV input voltage500 Vmaximum DC input voltage Raw/footnote context: 500V
Official source ↗ · Datasheet specification table row 'max_dc_voltage_v', exact-model column 'MIC 600TL-X2'
Revision: 2026.5 Update · Checked 2026-10-02
Maximum input current per tracker/input16 Amaximum input current at MPP-tracker scope Raw/footnote context: 16A
Official source ↗ · Datasheet specification table row 'max_input_current_per_mppt_a', exact-model column 'MIC 600TL-X2'
Revision: 2026.5 Update · Checked 2026-10-02
Maximum PV short-circuit current24 Amaximum short-circuit current at MPP-tracker scope Raw/footnote context: 24A
Official source ↗ · Datasheet specification table row 'max_short_circuit_current_per_mppt_a', exact-model column 'MIC 600TL-X2'
Revision: 2026.5 Update · Checked 2026-10-02
Efficiency & environment
Maximum conversion efficiency96.5 %maximum efficiency Raw/footnote context: 96.5%
Official source ↗ · Datasheet specification table row 'max_efficiency_pct', exact-model column 'MIC 600TL-X2'
Revision: 2026.5 Update · Checked 2026-10-02
European efficiency95.5 %European efficiency Raw/footnote context: 95.5%
Official source ↗ · Datasheet specification table row 'european_efficiency_pct', exact-model column 'MIC 600TL-X2'
Revision: 2026.5 Update · Checked 2026-10-02
Operating ambient temperature minimum-30 °Cambient operating temperature range; lower ambient operating-temperature bound. Raw/footnote context: -30°C...+60°C
Official source ↗ · Datasheet specification table row 'operating_temperature_c', exact-model column 'MIC 600TL-X2'
Revision: 2026.5 Update · Checked 2026-10-02
Operating ambient temperature maximum60 °Cambient operating temperature range; upper ambient operating-temperature bound. Raw/footnote context: -30°C...+60°C
Official source ↗ · Datasheet specification table row 'operating_temperature_c', exact-model column 'MIC 600TL-X2'
Revision: 2026.5 Update · Checked 2026-10-02
Enclosure protectionIP66ip rating Raw/footnote context: IP66
Official source ↗ · Datasheet specification table row 'ip_rating', exact-model column 'MIC 600TL-X2'
Revision: 2026.5 Update · Checked 2026-10-02
Surge protectionDC: Type III; AC: Type IIIManufacturer-published surge-protection rows; AC/DC scope preserved exactly. No safety approval inferred. Raw/footnote context: Type III | Type III
Official source ↗ · Datasheet specification table row 'dc_surge_protection', exact-model column 'MIC 600TL-X2' | Datasheet specification table row 'ac_surge_protection', exact-model column 'MIC 600TL-X2'
Revision: 2026.5 Update · Checked 2026-10-02
Warranty
Warranty and eligibility10 years standardstandard/optional warranty duration Raw/footnote context: 10 years
Official source ↗ · Datasheet specification table row 'warranty_years', exact-model column 'MIC 600TL-X2'
Revision: 2026.5 Update · Checked 2026-10-02

Comparison category basis

Official Task10/Growatt category identifies a PV inverter/string-type product; no microinverter or MLPE evidence is present.

Generic artwork is presentation-only and is not hardware, compatibility, dimension or electrical evidence.