Growatt New Energy
Growatt New Energy MIC 600TL-X2
MIC 600-3300TL-X2
String inverter
Growatt New Energy MIC 600TL-X2 has a reviewed nominal AC active-power rating of 600 W.
Deep comparison fields reviewedThis local comparison record does not approve module compatibility, string sizing, grid connection or electrical safety.
Documented source scope: Germany. This is not a statement about your location or product availability.
Representative illustration — not the manufacturer’s exact hardware appearance.
Field-level provenance
Electrical specifications
Unknown means the field has not passed this exact-record integration review. It does not mean zero.
| AC output | |
|---|---|
| Rated AC active power | 600 Wrated/nominal AC active output power Raw/footnote context: 600W Official source ↗ · Datasheet specification table row 'rated_ac_output_w', exact-model column 'MIC 600TL-X2' Revision: 2026.5 Update · Checked 2026-10-02 |
| Maximum AC apparent output | 600 VAmaximum AC apparent output power Raw/footnote context: 600VA Official source ↗ · Datasheet specification table row 'max_ac_apparent_power_va', exact-model column 'MIC 600TL-X2' Revision: 2026.5 Update · Checked 2026-10-02 |
| Connection phases | 1Task10 exact-model evidence records phase as 'Single phase'; normalized to 1 connection phase(s). Identity/category source is official Growatt evidence; no grid approval inferred. Raw/footnote context: Type III Official source ↗ · Task10 exact-model record invmfr_growatt|MIC 600TL-X2|Germany field 'phase'; official identity anchor: Datasheet specification table row 'ac_surge_protection', exact-model column 'MIC 600TL-X2'; source is bound to exact-model record MIC 600TL-X2. Revision: 2026.5 Update · Checked 2026-10-02 |
| PV input & tracking | |
| Independent MPPT trackers | 1independent MPP tracker count Raw/footnote context: 1 Official source ↗ · Datasheet specification table row 'mppt_count', exact-model column 'MIC 600TL-X2' Revision: 2026.5 Update · Checked 2026-10-02 |
| MPPT operating window minimum | 50 VMPPT operating voltage range; not full-power range unless explicitly stated; lower bound of the manufacturer MPPT operating range. Raw/footnote context: 50-500V Official source ↗ · Datasheet specification table row 'mppt_operating_range_v', exact-model column 'MIC 600TL-X2' Revision: 2026.5 Update · Checked 2026-10-02 |
| MPPT operating window maximum | 500 VMPPT operating voltage range; not full-power range unless explicitly stated; upper bound of the manufacturer MPPT operating range. Raw/footnote context: 50-500V Official source ↗ · Datasheet specification table row 'mppt_operating_range_v', exact-model column 'MIC 600TL-X2' Revision: 2026.5 Update · Checked 2026-10-02 |
| DC operating voltage minimum | Unknown |
| DC operating voltage maximum | Unknown |
| Maximum PV input voltage | 500 Vmaximum DC input voltage Raw/footnote context: 500V Official source ↗ · Datasheet specification table row 'max_dc_voltage_v', exact-model column 'MIC 600TL-X2' Revision: 2026.5 Update · Checked 2026-10-02 |
| Maximum input current per tracker/input | 16 Amaximum input current at MPP-tracker scope Raw/footnote context: 16A Official source ↗ · Datasheet specification table row 'max_input_current_per_mppt_a', exact-model column 'MIC 600TL-X2' Revision: 2026.5 Update · Checked 2026-10-02 |
| Maximum PV short-circuit current | 24 Amaximum short-circuit current at MPP-tracker scope Raw/footnote context: 24A Official source ↗ · Datasheet specification table row 'max_short_circuit_current_per_mppt_a', exact-model column 'MIC 600TL-X2' Revision: 2026.5 Update · Checked 2026-10-02 |
| Efficiency & environment | |
| Maximum conversion efficiency | 96.5 %maximum efficiency Raw/footnote context: 96.5% Official source ↗ · Datasheet specification table row 'max_efficiency_pct', exact-model column 'MIC 600TL-X2' Revision: 2026.5 Update · Checked 2026-10-02 |
| European efficiency | 95.5 %European efficiency Raw/footnote context: 95.5% Official source ↗ · Datasheet specification table row 'european_efficiency_pct', exact-model column 'MIC 600TL-X2' Revision: 2026.5 Update · Checked 2026-10-02 |
| Operating ambient temperature minimum | -30 °Cambient operating temperature range; lower ambient operating-temperature bound. Raw/footnote context: -30°C...+60°C Official source ↗ · Datasheet specification table row 'operating_temperature_c', exact-model column 'MIC 600TL-X2' Revision: 2026.5 Update · Checked 2026-10-02 |
| Operating ambient temperature maximum | 60 °Cambient operating temperature range; upper ambient operating-temperature bound. Raw/footnote context: -30°C...+60°C Official source ↗ · Datasheet specification table row 'operating_temperature_c', exact-model column 'MIC 600TL-X2' Revision: 2026.5 Update · Checked 2026-10-02 |
| Enclosure protection | IP66ip rating Raw/footnote context: IP66 Official source ↗ · Datasheet specification table row 'ip_rating', exact-model column 'MIC 600TL-X2' Revision: 2026.5 Update · Checked 2026-10-02 |
| Surge protection | DC: Type III; AC: Type IIIManufacturer-published surge-protection rows; AC/DC scope preserved exactly. No safety approval inferred. Raw/footnote context: Type III | Type III Official source ↗ · Datasheet specification table row 'dc_surge_protection', exact-model column 'MIC 600TL-X2' | Datasheet specification table row 'ac_surge_protection', exact-model column 'MIC 600TL-X2' Revision: 2026.5 Update · Checked 2026-10-02 |
| Warranty | |
| Warranty and eligibility | 10 years standardstandard/optional warranty duration Raw/footnote context: 10 years Official source ↗ · Datasheet specification table row 'warranty_years', exact-model column 'MIC 600TL-X2' Revision: 2026.5 Update · Checked 2026-10-02 |
Comparison category basis
Official Task10/Growatt category identifies a PV inverter/string-type product; no microinverter or MLPE evidence is present.
Generic artwork is presentation-only and is not hardware, compatibility, dimension or electrical evidence.