Growatt New Energy

Growatt New Energy MOD 12KTL3-X

MOD 10-15KTL3-X

String inverter

Growatt New Energy MOD 12KTL3-X has a reviewed nominal AC active-power rating of 12000 W.

Deep comparison fields reviewed

This local comparison record does not approve module compatibility, string sizing, grid connection or electrical safety.

Documented source scope: Global / ROW (Growatt English Worldwide catalog). This is not a statement about your location or product availability.

Official model/market source ↗

Choose an inverter to compare →

Generic representative string inverter illustration

Representative illustration — not the manufacturer’s exact hardware appearance.

Field-level provenance

Electrical specifications

16/18 display fields reviewed

Unknown means the field has not passed this exact-record integration review. It does not mean zero.

MOD 12KTL3-X specifications
AC output
Rated AC active power12000 WManufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval.
Official source ↗ · Datasheet specification table row 'rated_ac_output_w', exact-model column 'MOD 12KTL3-X'
Revision: 2026.5 Update · Checked 2026-10-02
Maximum AC apparent output13200 VAManufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval.
Official source ↗ · Datasheet specification table row 'max_ac_apparent_power_va', exact-model column 'MOD 12KTL3-X'
Revision: 2026.5 Update · Checked 2026-10-02
Connection phasesthree_phaseExact model/market phase classification retained from Task10 source-worker review; no cross-model interpolation.
Official source ↗ · Task10 exact-model canonical record: phase=Three phase; official manufacturer family/product evidence retained in provenance_refs.
Revision: 2026.5 Update · Checked 2026-10-02
PV input & tracking
Independent MPPT trackers2Manufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval.
Official source ↗ · Datasheet specification table row 'mppt_count', exact-model column 'MOD 12KTL3-X'
Revision: 2026.5 Update · Checked 2026-10-02
MPPT operating window minimum140 VManufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval.
Official source ↗ · Datasheet specification table row 'mppt_operating_range_v', exact-model column 'MOD 12KTL3-X'
Revision: 2026.5 Update · Checked 2026-10-02
MPPT operating window maximum1000 VManufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval.
Official source ↗ · Datasheet specification table row 'mppt_operating_range_v', exact-model column 'MOD 12KTL3-X'
Revision: 2026.5 Update · Checked 2026-10-02
DC operating voltage minimumUnknown
DC operating voltage maximumUnknown
Maximum PV input voltage1100 VManufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval.
Official source ↗ · Datasheet specification table row 'max_dc_voltage_v', exact-model column 'MOD 12KTL3-X'
Revision: 2026.5 Update · Checked 2026-10-02
Maximum input current per tracker/input13 / 26 AManufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval.
Official source ↗ · Datasheet specification table row 'max_input_current_per_mppt_a', exact-model column 'MOD 12KTL3-X'
Revision: 2026.5 Update · Checked 2026-10-02
Maximum PV short-circuit current16 / 32 AManufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval.
Official source ↗ · Datasheet specification table row 'max_short_circuit_current_per_mppt_a', exact-model column 'MOD 12KTL3-X'
Revision: 2026.5 Update · Checked 2026-10-02
Efficiency & environment
Maximum conversion efficiency98.6 %Manufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval.
Official source ↗ · Datasheet specification table row 'max_efficiency_pct', exact-model column 'MOD 12KTL3-X'
Revision: 2026.5 Update · Checked 2026-10-02
European efficiency98.2 %Manufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval.
Official source ↗ · Datasheet specification table row 'european_efficiency_pct', exact-model column 'MOD 12KTL3-X'
Revision: 2026.5 Update · Checked 2026-10-02
Operating ambient temperature minimum-25 °CManufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval.
Official source ↗ · Datasheet specification table row 'operating_temperature_c', exact-model column 'MOD 12KTL3-X'
Revision: 2026.5 Update · Checked 2026-10-02
Operating ambient temperature maximum60 °CManufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval.
Official source ↗ · Datasheet specification table row 'operating_temperature_c', exact-model column 'MOD 12KTL3-X'
Revision: 2026.5 Update · Checked 2026-10-02
Enclosure protectionIP66Manufacturer exact-model specification as published; no compatibility, string-sizing, grid, design, safety, or live-publication approval.
Official source ↗ · Datasheet specification table row 'ip_rating', exact-model column 'MOD 12KTL3-X'
Revision: 2026.5 Update · Checked 2026-10-02
Surge protectionDC Type II / AC Type IIPublished DC/AC surge-protection types preserved separately; no safety approval is implied.
Official source ↗ · Datasheet specification table row 'dc_surge_protection', exact-model column 'MOD 12KTL3-X'; Datasheet specification table row 'ac_surge_protection', exact-model column 'MOD 12KTL3-X'
Revision: 2026.5 Update · Checked 2026-10-02
Warranty
Warranty and eligibilitystandard 5 / optional 10Manufacturer warranty statement/options as published; eligibility and local terms may vary and are not independently granted by this catalogue review. QC schema normalization: canonical display-field unit is ''; original Task18 unit metadata was 'years'. The value semantics are preserved in the field value/test condition.
Official source ↗ · Datasheet specification table row 'warranty_years', exact-model column 'MOD 12KTL3-X'
Revision: 2026.5 Update · Checked 2026-10-02