Fox ESS
Fox ESS H3-8.0-Smart
H3 Smart
Hybrid / smart energy inverter
Fox ESS H3-8.0-Smart has a reviewed nominal AC active-power rating of 8000 W.
Deep comparison fields reviewedThis local comparison record does not approve module compatibility, string sizing, grid connection or electrical safety.
Documented source scope: Global / ROW official site. This is not a statement about your location or product availability. manufacturer-id + exact model code + market; no cross-region, power-bin, suffix, phase, certification or hardware-generation merge
Representative illustration — not the manufacturer’s exact hardware appearance.
Field-level provenance
Electrical specifications
Unknown means the field has not passed this exact-record integration review. It does not mean zero.
| AC output | |
|---|---|
| Rated AC active power | 8000 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ · technical table Nominal AC Power Revision: V2.0 · Checked 2026-10-02 |
| Maximum AC apparent output | 8800 VAmaximum apparent AC output for stated market; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ · technical table Max. Apparent AC Power; Belgium footnote where applicable Revision: V2.0 · Checked 2026-10-02 |
| Connection phases | 3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference. Official source ↗ · p.2 AC OUTPUT — Rated Grid Voltage 400/230 V; 380/220 V, 3L/N/PE; exact model column Revision: V2.0 · Checked 2026-10-02 |
| PV input & tracking | |
| Independent MPPT trackers | 3independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ · technical table No. of MPP Trackers Revision: V2.0 · Checked 2026-10-02 |
| MPPT operating window minimum | 120 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ · technical table MPPT Voltage Range; canonical min bound from source range Revision: V2.0 · Checked 2026-10-02 |
| MPPT operating window maximum | 950 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ · technical table MPPT Voltage Range; canonical max bound from source range Revision: V2.0 · Checked 2026-10-02 |
| DC operating voltage minimum | Unknown |
| DC operating voltage maximum | Unknown |
| Maximum PV input voltage | 1000 Vmaximum DC voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ · technical table Max. DC Voltage; note max operating 950V Revision: V2.0 · Checked 2026-10-02 |
| Maximum input current per tracker/input | 20 / 20 / 20 Amaximum current by MPPT; scope: MPPT1/2/3; raw source cell retained: 20/20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ · technical table Max. MPPT Current Revision: V2.0 · Checked 2026-10-02 |
| Maximum PV short-circuit current | 25 / 25 / 25 Amaximum short-circuit current by MPPT; scope: MPPT1/2/3; raw source cell retained: 25/25/25; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ · technical table Max. Short-circuit Current Revision: V2.0 · Checked 2026-10-02 |
| Efficiency & environment | |
| Maximum conversion efficiency | 97.7 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ · technical table Max. Efficiency Revision: V2.0 · Checked 2026-10-02 |
| European efficiency | 97.2 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ · technical table European Efficiency Revision: V2.0 · Checked 2026-10-02 |
| Operating ambient temperature minimum | -25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ · technical table Operating Temperature; canonical min bound from source range Revision: V2.0 · Checked 2026-10-02 |
| Operating ambient temperature maximum | 60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ · technical table Operating Temperature; canonical max bound from source range Revision: V2.0 · Checked 2026-10-02 |
| Enclosure protection | IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ · technical table Ingress Protection Revision: V2.0 · Checked 2026-10-02 |
| Surge protection | DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval. Official source ↗ · p.2 PROTECTION — DC/AC Surge Protection row Revision: V2.0 · Checked 2026-10-02 |
| Warranty | |
| Warranty and eligibility | Unknown |
Comparison category basis
Official exact-model/family evidence supports source category 'PV + battery hybrid inverter'; normalized only to the allowed comparison category 'hybrid'.
Generic artwork is presentation-only and is not hardware, compatibility, dimension or electrical evidence.