PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← All inverters

Fox ESS

Fox ESS H3-8.0-Smart

H3 Smart

Hybrid / smart energy inverter

Fox ESS H3-8.0-Smart has a reviewed nominal AC active-power rating of 8000 W.

Deep comparison fields reviewed

This local comparison record does not approve module compatibility, string sizing, grid connection or electrical safety.

Documented source scope: Global / ROW official site. This is not a statement about your location or product availability. manufacturer-id + exact model code + market; no cross-region, power-bin, suffix, phase, certification or hardware-generation merge

Official model/market source ↗

Choose an inverter to compare →

Generic representative hybrid / smart energy inverter illustration

Representative illustration — not the manufacturer’s exact hardware appearance.

Field-level provenance

Electrical specifications

15/18 display fields reviewed

Unknown means the field has not passed this exact-record integration review. It does not mean zero.

H3-8.0-Smart specifications
AC output
Rated AC active power8000 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗ · technical table Nominal AC Power
Revision: V2.0 · Checked 2026-10-02
Maximum AC apparent output8800 VAmaximum apparent AC output for stated market; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗ · technical table Max. Apparent AC Power; Belgium footnote where applicable
Revision: V2.0 · Checked 2026-10-02
Connection phases3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗ · p.2 AC OUTPUT — Rated Grid Voltage 400/230 V; 380/220 V, 3L/N/PE; exact model column
Revision: V2.0 · Checked 2026-10-02
PV input & tracking
Independent MPPT trackers3independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗ · technical table No. of MPP Trackers
Revision: V2.0 · Checked 2026-10-02
MPPT operating window minimum120 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗ · technical table MPPT Voltage Range; canonical min bound from source range
Revision: V2.0 · Checked 2026-10-02
MPPT operating window maximum950 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗ · technical table MPPT Voltage Range; canonical max bound from source range
Revision: V2.0 · Checked 2026-10-02
DC operating voltage minimumUnknown
DC operating voltage maximumUnknown
Maximum PV input voltage1000 Vmaximum DC voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗ · technical table Max. DC Voltage; note max operating 950V
Revision: V2.0 · Checked 2026-10-02
Maximum input current per tracker/input20 / 20 / 20 Amaximum current by MPPT; scope: MPPT1/2/3; raw source cell retained: 20/20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗ · technical table Max. MPPT Current
Revision: V2.0 · Checked 2026-10-02
Maximum PV short-circuit current25 / 25 / 25 Amaximum short-circuit current by MPPT; scope: MPPT1/2/3; raw source cell retained: 25/25/25; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗ · technical table Max. Short-circuit Current
Revision: V2.0 · Checked 2026-10-02
Efficiency & environment
Maximum conversion efficiency97.7 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗ · technical table Max. Efficiency
Revision: V2.0 · Checked 2026-10-02
European efficiency97.2 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗ · technical table European Efficiency
Revision: V2.0 · Checked 2026-10-02
Operating ambient temperature minimum-25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗ · technical table Operating Temperature; canonical min bound from source range
Revision: V2.0 · Checked 2026-10-02
Operating ambient temperature maximum60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗ · technical table Operating Temperature; canonical max bound from source range
Revision: V2.0 · Checked 2026-10-02
Enclosure protectionIP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗ · technical table Ingress Protection
Revision: V2.0 · Checked 2026-10-02
Surge protectionDC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗ · p.2 PROTECTION — DC/AC Surge Protection row
Revision: V2.0 · Checked 2026-10-02
Warranty
Warranty and eligibilityUnknown

Comparison category basis

Official exact-model/family evidence supports source category 'PV + battery hybrid inverter'; normalized only to the allowed comparison category 'hybrid'.

Generic artwork is presentation-only and is not hardware, compatibility, dimension or electrical evidence.