APsystems
APsystems QT2-230
QT2 Series
Microinverter
Deep comparison fields reviewedThis local comparison record does not approve module compatibility, string sizing, grid connection or electrical safety.
Documented source scope: Philippines. This is not a statement about your location or product availability. Exact market 'Philippines' retained; no regional interpolation or variant merge.
Representative illustration — not the manufacturer’s exact hardware appearance.
Field-level provenance
Electrical specifications
Unknown means the field has not passed this exact-record integration review. It does not mean zero.
| AC output | |
|---|---|
| Rated AC active power | Unknown |
| Maximum AC apparent output | 1728 VAmaximum continuous apparent output; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ · PDF p1 Output Data Revision: Rev1.5 · Checked 2026-10-02 |
| Connection phases | 3Connection phase stated by the exact official family/model evidence and Task10 exact identity record; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ · Exact-model official document / Output Data or topology / QT2-230 / phase connection Revision: Rev1.5 · Checked 2026-10-02 |
| PV input & tracking | |
| Independent MPPT trackers | 2family topology; dual MPPT; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ · datasheet topology/4-input paired tracking Revision: Rev1.5 · Checked 2026-10-02 |
| MPPT operating window minimum | 30 Vmanufacturer-published text/range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ · PDF p1 Input Data Revision: Rev1.5 · Checked 2026-10-02 |
| MPPT operating window maximum | 45 Vmanufacturer-published text/range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ · PDF p1 Input Data Revision: Rev1.5 · Checked 2026-10-02 |
| DC operating voltage minimum | Unknown |
| DC operating voltage maximum | Unknown |
| Maximum PV input voltage | 60 Vmaximum input voltage; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ · PDF p1 Input Data Revision: Rev1.5 · Checked 2026-10-02 |
| Maximum input current per tracker/input | 20 Amaximum input current; four inputs; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ · PDF p1 Input Data Revision: Rev1.5 · Checked 2026-10-02 |
| Maximum PV short-circuit current | 25 Amaximum input short-circuit current; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ · PDF p1 Input Data Revision: Rev1.5 · Checked 2026-10-02 |
| Efficiency & environment | |
| Maximum conversion efficiency | 95 %peak efficiency; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ · PDF p1 Efficiency Revision: Rev1.5 · Checked 2026-10-02 |
| European efficiency | Unknown |
| Operating ambient temperature minimum | -40 °Cmanufacturer-published text/range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ · PDF p1 Mechanical Data Revision: Rev1.5 · Checked 2026-10-02 |
| Operating ambient temperature maximum | 65 °Cmanufacturer-published text/range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ · PDF p1 Mechanical Data Revision: Rev1.5 · Checked 2026-10-02 |
| Enclosure protection | Type 6 / IP67manufacturer-published text/range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ · PDF p1 Mechanical Data Revision: Rev1.5 · Checked 2026-10-02 |
| Surge protection | Unknown |
| Warranty | |
| Warranty and eligibility | 12 yearsstandard warranty; subject to terms/EMA monitoring; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ · PDF p1 Features/footnote Revision: Rev1.5 · Checked 2026-10-02 |
Comparison category basis
Task10 exact identity category/family: microinverter; normalized to microinverter.
Generic artwork is presentation-only and is not hardware, compatibility, dimension or electrical evidence.