SIDE BY SIDE, SOURCE BY SOURCE
Small details.
Clear differences.
Compare exact models without a universal winner.
Different market variants are not assumed interchangeable.
Technical specifications incomplete
Deep electrical comparison requires reviewed core fields and consistent STC values for every selected model. Review the reasons below and the exact source documents.
- LR7-54HVHF-480M · Europe
missing reviewed power, voc, vmp, isc, imp, temperature.
Highlighted rows differ in value, unit, test condition or rating scope. “Not verified” is an unknown, never zero. On small screens, scroll the table sideways.
| SpecificationsReview condition and scope | JA SolarJAM54D50-535/GRGlobal535 W | LONGiLR7-54HVHF-480MEurope480 W |
|---|---|---|
| Electrical · standard test conditions | ||
Rated powerⓘLaboratory DC nameplate power; this is not an annual energy estimate. | 535 W
EvidenceSource ↗
STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexSTCScope exact_model_columnSource unit WRevision 中文-CN-20260417AChecked 2026-10-02 | 480 W |
| Physical specifications | ||
LengthⓘNominal manufacturer dimension. | 1961 mm | 1800 mm |
WidthⓘNominal manufacturer dimension. | 1134 mm
EvidenceSource ↗
STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit mmRevision 中文-CN-20260417AChecked 2026-10-02 | 1134 mm |
ThicknessⓘUnknown thickness is never inferred from a nearby model. | 30 mm
EvidenceSource ↗
STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit mmRevision 中文-CN-20260417AChecked 2026-10-02 | 30 mm |
Cell technologyⓘShown only when this field has passed integration review. | Not verified | Not verified |
Module typeⓘBifacial modules can receive light on both faces; this is not a yield prediction. | Not verified | Not verified |
WeightⓘNominal weight for this documented construction. | 27.4 kg
EvidenceSource ↗
STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit kgRevision 中文-CN-20260417AChecked 2026-10-02 | Not verified |
| Temperature & warranty | ||
Power temperature coefficientⓘChange in rated power per degree; sign and test basis matter. | -0.26 %/°C
EvidenceSource ↗
STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit %/°CRevision 中文-CN-20260417AChecked 2026-10-02 | Not verified |
Voltage temperature coefficientⓘRequired for temperature-corrected voltage calculations. | -0.22 %/°C
EvidenceSource ↗
STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit %/°CRevision 中文-CN-20260417AChecked 2026-10-02 | Not verified |
Current temperature coefficientⓘManufacturer coefficient under its stated test conditions. | 0.041 %/°C
EvidenceSource ↗
STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit %/°CRevision 中文-CN-20260417AChecked 2026-10-02 | Not verified |
Nominal module operating temperatureⓘNMOT is distinct from STC cell temperature. | Not verified | Not verified |
Nominal operating cell temperatureⓘNOCT is not substituted for NMOT. | 45 °C
EvidenceSource ↗
STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit °CRevision 中文-CN-20260417AChecked 2026-10-02 | Not verified |
Maximum system voltageⓘA module rating, not approval of a proposed string. | 1500 V
EvidenceSource ↗
STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit VRevision 中文-CN-20260417AChecked 2026-10-02 | Not verified |
Maximum series fuse ratingⓘInstallation protection still requires a separate design review. | 30 A
EvidenceSource ↗
STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit ARevision 中文-CN-20260417AChecked 2026-10-02 | Not verified |
Power bifacialityⓘRear/front power ratio under the documented condition, not a production uplift. | Not verified | Not verified |
Minimum operating temperatureⓘManufacturer operating range; not ambient design temperature. | -40 °C
EvidenceSource ↗
STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit °CRevision 中文-CN-20260417AChecked 2026-10-02 | Not verified |
Maximum operating temperatureⓘObserve the stated qualifications, including short-term limits. | 70 °C
EvidenceSource ↗
STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit °CRevision 中文-CN-20260417AChecked 2026-10-02 | Not verified |
Warranty termsⓘEligibility and market-specific conditions must be reviewed. | Not verified | Not verified |
| Identity & evidence | ||
Market scopeⓘDifferent market variants are not assumed interchangeable. | Global | Europe |
Product familyⓘThe family label does not establish equivalence. | DeepBlue 5.0 | Hi-MO X10 Guardian Anti-Dust LR7-54HVHF |
Datasheet revisionⓘSpecifications can change between document revisions. | 中文-CN-20260417A | Not verified |
Datasheet dateⓘUnknown when not established in the approved record. | 2026-04-17 | Not verified |
Source verification dateⓘDate recorded in the source evidence. | 2026-10-02 | 2026-10-02 |
Last integration checkⓘDate of the independent import review. | 2026-10-02 | 2026-10-02 |
| Official source | Datasheet ↗ Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | Datasheet ↗ Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
Specs can vary by market/revision. These are equipment specifications, not an electrical compatibility verdict. Module voltage is not household voltage. Installation suitability requires a separate professional assessment.