PUBLIC CATALOGUE • 1124 solar panel records. Technical coverage is shown separately.

SIDE BY SIDE, SOURCE BY SOURCE

Small details.
Clear differences.

Compare exact models without a universal winner.
Different market variants are not assumed interchangeable.

Edit selection

Highlighted rows differ in value, unit, test condition or rating scope. “Not verified” is an unknown, never zero. On small screens, scroll the table sideways.

2 exact models, grouped specifications
SpecificationsReview condition and scopeJA SolarJAM54D50-530/GRGlobal530 WJinkoSolarJKM665N-66QL6-BDVEurope665 W
Electrical · standard test conditions
Rated power
ⓘ

Laboratory DC nameplate power; this is not an annual energy estimate.

530 W
Evidence
Source ↗ STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexSTCScope exact_model_columnSource unit WRevision 中文-CN-20260417AChecked 2026-10-02
665 W
Evidence
Source ↗ PDF page 2, STC 665 W column 4, power rowSTCScope exact_model_columnSource unit WRevision F4-EUChecked 2026-10-02
Open-circuit voltage
ⓘ

Module voltage without a load. It is not household voltage.

40.88 V
Evidence
Source ↗ STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexSTCScope exact_model_columnSource unit VRevision 中文-CN-20260417AChecked 2026-10-02
50.55 V
Evidence
Source ↗ PDF page 2, STC 665 W column 4, voc rowSTCScope exact_model_columnSource unit VRevision F4-EUChecked 2026-10-02
Voltage at maximum power
ⓘ

Module operating voltage at STC.

33.26 V
Evidence
Source ↗ STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexSTCScope exact_model_columnSource unit VRevision 中文-CN-20260417AChecked 2026-10-02
42.85 V
Evidence
Source ↗ PDF page 2, STC 665 W column 4, vmp rowSTCScope exact_model_columnSource unit VRevision F4-EUChecked 2026-10-02
Short-circuit current
ⓘ

Module current under the stated test condition.

16.73 A
Evidence
Source ↗ STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexSTCScope exact_model_columnSource unit ARevision 中文-CN-20260417AChecked 2026-10-02
16.24 A
Evidence
Source ↗ PDF page 2, STC 665 W column 4, isc rowSTCScope exact_model_columnSource unit ARevision F4-EUChecked 2026-10-02
Current at maximum power
ⓘ

Module operating current at STC.

15.93 A
Evidence
Source ↗ STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexSTCScope exact_model_columnSource unit ARevision 中文-CN-20260417AChecked 2026-10-02
15.52 A
Evidence
Source ↗ PDF page 2, STC 665 W column 4, imp rowSTCScope exact_model_columnSource unit ARevision F4-EUChecked 2026-10-02
Module efficiency
ⓘ

Exact STC power column, not bifacial rear-side gain.

23.8 %
Evidence
Source ↗ STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexSTCScope exact_model_columnSource unit %Revision 中文-CN-20260417AChecked 2026-10-02
24.62 %
Evidence
Source ↗ PDF page 2, STC 665 W column 4, efficiency rowSTCScope exact_model_columnSource unit %Revision F4-EUChecked 2026-10-02
Physical specifications
Length
ⓘ

Nominal manufacturer dimension.

1961 mm 2382 mm
Evidence
Source ↗ PDF page 2, family length rowManufacturer nominal family ratingScope familySource unit mmRevision F4-EUChecked 2026-10-02
Width
ⓘ

Nominal manufacturer dimension.

1134 mm
Evidence
Source ↗ STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit mmRevision 中文-CN-20260417AChecked 2026-10-02
1134 mm
Evidence
Source ↗ PDF page 2, family width rowManufacturer nominal family ratingScope familySource unit mmRevision F4-EUChecked 2026-10-02
Thickness
ⓘ

Unknown thickness is never inferred from a nearby model.

30 mm
Evidence
Source ↗ STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit mmRevision 中文-CN-20260417AChecked 2026-10-02
30 mm
Evidence
Source ↗ PDF page 2, family thickness rowManufacturer nominal family ratingScope familySource unit mmRevision F4-EUChecked 2026-10-02
Cell technology
ⓘ

Shown only when this field has passed integration review.

Not verified Not verified
Module type
ⓘ

Bifacial modules can receive light on both faces; this is not a yield prediction.

Not verified Not verified
Weight
ⓘ

Nominal weight for this documented construction.

27.4 kg
Evidence
Source ↗ STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit kgRevision 中文-CN-20260417AChecked 2026-10-02
32.5 kg
Evidence
Source ↗ PDF page 2, family weight rowManufacturer nominal family ratingScope familySource unit kgRevision F4-EUChecked 2026-10-02
Temperature & warranty
Power temperature coefficient
ⓘ

Change in rated power per degree; sign and test basis matter.

-0.26 %/°C
Evidence
Source ↗ STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit %/°CRevision 中文-CN-20260417AChecked 2026-10-02
-0.26 %/°C
Evidence
Source ↗ PDF page 2, family temperature rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision F4-EUChecked 2026-10-02
Voltage temperature coefficient
ⓘ

Required for temperature-corrected voltage calculations.

-0.22 %/°C
Evidence
Source ↗ STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit %/°CRevision 中文-CN-20260417AChecked 2026-10-02
-0.24 %/°C
Evidence
Source ↗ PDF page 2, family temperature_voc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision F4-EUChecked 2026-10-02
Current temperature coefficient
ⓘ

Manufacturer coefficient under its stated test conditions.

0.041 %/°C
Evidence
Source ↗ STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit %/°CRevision 中文-CN-20260417AChecked 2026-10-02
0.046 %/°C
Evidence
Source ↗ PDF page 2, family temperature_isc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision F4-EUChecked 2026-10-02
Nominal module operating temperature
ⓘ

NMOT is distinct from STC cell temperature.

Not verified Not verified
Nominal operating cell temperature
ⓘ

NOCT is not substituted for NMOT.

45 °C
Evidence
Source ↗ STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit °CRevision 中文-CN-20260417AChecked 2026-10-02
Not verified
Maximum system voltage
ⓘ

A module rating, not approval of a proposed string.

1500 V
Evidence
Source ↗ STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit VRevision 中文-CN-20260417AChecked 2026-10-02
1500 V
Evidence
Source ↗ PDF page 2, family max_system_voltage rowManufacturer nominal family ratingScope familySource unit VRevision F4-EUChecked 2026-10-02
Maximum series fuse rating
ⓘ

Installation protection still requires a separate design review.

30 A
Evidence
Source ↗ STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit ARevision 中文-CN-20260417AChecked 2026-10-02
35 A
Evidence
Source ↗ PDF page 2, family series_fuse rowManufacturer nominal family ratingScope familySource unit ARevision F4-EUChecked 2026-10-02
Power bifaciality
ⓘ

Rear/front power ratio under the documented condition, not a production uplift.

Not verified 85 %
Evidence
Source ↗ PDF page 2, family bifaciality rowPmax bifaciality, +/-5 percentage pointsScope familySource unit %Revision F4-EUChecked 2026-10-02
Minimum operating temperature
ⓘ

Manufacturer operating range; not ambient design temperature.

-40 °C
Evidence
Source ↗ STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit °CRevision 中文-CN-20260417AChecked 2026-10-02
-40 °C
Evidence
Source ↗ PDF page 2, family operating_min rowManufacturer nominal family ratingScope familySource unit °CRevision F4-EUChecked 2026-10-02
Maximum operating temperature
ⓘ

Observe the stated qualifications, including short-term limits.

70 °C
Evidence
Source ↗ STC electrical table; mechanical table; application conditions; exact family is also listed under Global on JA Solar Product Datasheets indexmanufacturer_datasheetScope family_shared_valueSource unit °CRevision 中文-CN-20260417AChecked 2026-10-02
70 °C
Evidence
Source ↗ PDF page 2, family operating_max rowOperating range upper limit; T98 <=70 C; short-term up to85 C, higher operation requires IEC TS 63126 testingScope familySource unit °CRevision F4-EUChecked 2026-10-02
Warranty terms
ⓘ

Eligibility and market-specific conditions must be reviewed.

Not verified Not verified
Identity & evidence
Market scope
ⓘ

Different market variants are not assumed interchangeable.

Global Europe
Product family
ⓘ

The family label does not establish equivalence.

DeepBlue 5.0 Tiger Neo 3.0 — 66QL6-BDV
Datasheet revision
ⓘ

Specifications can change between document revisions.

中文-CN-20260417A F4-EU
Datasheet date
ⓘ

Unknown when not established in the approved record.

2026-04-17 Not verified
Source verification date
ⓘ

Date recorded in the source evidence.

2026-10-02 2026-10-01
Last integration check
ⓘ

Date of the independent import review.

2026-10-02 2026-10-01
Official sourceDatasheet ↗

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Datasheet ↗

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Specs can vary by market/revision. These are equipment specifications, not an electrical compatibility verdict. Module voltage is not household voltage. Installation suitability requires a separate professional assessment.