SIDE BY SIDE, SOURCE BY SOURCE
Small details.
Clear differences.
Compare exact models without a universal winner.
Different market variants are not assumed interchangeable.
Technical specifications incomplete
Deep electrical comparison requires reviewed core fields and consistent STC values for every selected model. Review the reasons below and the exact source documents.
- REC410AA Pure-R · Australia / New Zealand
missing reviewed power, voc, vmp, isc, imp, temperature.
Highlighted rows differ in value, unit, test condition or rating scope. “Not verified” is an unknown, never zero. On small screens, scroll the table sideways.
| SpecificationsReview condition and scope | LONGiLR7-54HVB-450MEurope450 W | REC GroupREC410AA Pure-RAustralia / New Zealand410 W |
|---|---|---|
| Electrical · standard test conditions | ||
Rated powerⓘLaboratory DC nameplate power; this is not an annual energy estimate. | 450 W
EvidenceSource ↗
PDF page 2, STC 450 W column 2, power rowSTCScope exact_model_columnSource unit WRevision Not verifiedChecked 2026-10-02 | 410 W |
| Physical specifications | ||
LengthⓘNominal manufacturer dimension. | 1800 mm
EvidenceSource ↗
PDF page 2, family length rowManufacturer nominal family ratingScope familySource unit mmRevision Not verifiedChecked 2026-10-02 | 1730 mm |
WidthⓘNominal manufacturer dimension. | 1134 mm
EvidenceSource ↗
PDF page 2, family width rowManufacturer nominal family ratingScope familySource unit mmRevision Not verifiedChecked 2026-10-02 | 1118 mm |
ThicknessⓘUnknown thickness is never inferred from a nearby model. | 30 mm
EvidenceSource ↗
PDF page 2, family thickness rowManufacturer nominal family ratingScope familySource unit mmRevision Not verifiedChecked 2026-10-02 | 30 mm |
Cell technologyⓘShown only when this field has passed integration review. | Back-contact cells
EvidenceSource ↗
PDF page 2, family technology rowManufacturer nominal family ratingScope familyRevision Not verifiedChecked 2026-10-02 | Not verified |
Module typeⓘBifacial modules can receive light on both faces; this is not a yield prediction. | Not verified | Not verified |
WeightⓘNominal weight for this documented construction. | 21.6 kg
EvidenceSource ↗
PDF page 2, family weight rowManufacturer nominal family ratingScope familySource unit kgRevision Not verifiedChecked 2026-10-02 | Not verified |
| Temperature & warranty | ||
Power temperature coefficientⓘChange in rated power per degree; sign and test basis matter. | -0.26 %/°C
EvidenceSource ↗
PDF page 2, family temperature rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision Not verifiedChecked 2026-10-02 | Not verified |
Voltage temperature coefficientⓘRequired for temperature-corrected voltage calculations. | -0.2 %/°C
EvidenceSource ↗
PDF page 2, family temperature_voc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision Not verifiedChecked 2026-10-02 | Not verified |
Current temperature coefficientⓘManufacturer coefficient under its stated test conditions. | 0.05 %/°C
EvidenceSource ↗
PDF page 2, family temperature_isc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision Not verifiedChecked 2026-10-02 | Not verified |
Nominal module operating temperatureⓘNMOT is distinct from STC cell temperature. | Not verified | Not verified |
Nominal operating cell temperatureⓘNOCT is not substituted for NMOT. | 45 °C
EvidenceSource ↗
PDF page 2, family noct rowNominal operating cell temperature, +/-2 degrees CScope familySource unit °CRevision Not verifiedChecked 2026-10-02 | Not verified |
Maximum system voltageⓘA module rating, not approval of a proposed string. | 1500 V
EvidenceSource ↗
PDF page 2, family max_system_voltage rowManufacturer nominal family ratingScope familySource unit VRevision Not verifiedChecked 2026-10-02 | Not verified |
Maximum series fuse ratingⓘInstallation protection still requires a separate design review. | 25 A
EvidenceSource ↗
PDF page 2, family series_fuse rowManufacturer nominal family ratingScope familySource unit ARevision Not verifiedChecked 2026-10-02 | Not verified |
Power bifacialityⓘRear/front power ratio under the documented condition, not a production uplift. | Not verified | Not verified |
Minimum operating temperatureⓘManufacturer operating range; not ambient design temperature. | -40 °C
EvidenceSource ↗
PDF page 2, family operating_min rowManufacturer nominal family ratingScope familySource unit °CRevision Not verifiedChecked 2026-10-02 | Not verified |
Maximum operating temperatureⓘObserve the stated qualifications, including short-term limits. | 85 °C
EvidenceSource ↗
PDF page 2, family operating_max rowManufacturer nominal family ratingScope familySource unit °CRevision Not verifiedChecked 2026-10-02 | Not verified |
Warranty termsⓘEligibility and market-specific conditions must be reviewed. | Not verified | Not verified |
| Identity & evidence | ||
Market scopeⓘDifferent market variants are not assumed interchangeable. | Europe | Australia / New Zealand |
Product familyⓘThe family label does not establish equivalence. | EcoLife Anti-Glare Pro LR7-54HVB | REC Alpha Pure-R |
Datasheet revisionⓘSpecifications can change between document revisions. | Not verified | V4.2 |
Datasheet dateⓘUnknown when not established in the approved record. | Not verified | 2025-10 |
Source verification dateⓘDate recorded in the source evidence. | 2026-10-01 | 2026-10-01 |
Last integration checkⓘDate of the independent import review. | 2026-10-01 | 2026-10-01 |
| Official source | Datasheet ↗ Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 Reviewed archived document ↗Exact document hash 533c0aa86de8… · Printed revision unavailable | Datasheet ↗ Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
Specs can vary by market/revision. These are equipment specifications, not an electrical compatibility verdict. Module voltage is not household voltage. Installation suitability requires a separate professional assessment.