PUBLIC CATALOGUE • 1124 solar panel records. Technical coverage is shown separately.

SIDE BY SIDE, SOURCE BY SOURCE

Small details.
Clear differences.

Compare exact models without a universal winner.
Different market variants are not assumed interchangeable.

Technical specifications incomplete

Deep electrical comparison requires reviewed core fields and consistent STC values for every selected model. Review the reasons below and the exact source documents.

  • REC410AA Pure-R · Australia / New Zealand

    missing reviewed power, voc, vmp, isc, imp, temperature.

Edit selection

Highlighted rows differ in value, unit, test condition or rating scope. “Not verified” is an unknown, never zero. On small screens, scroll the table sideways.

2 exact models, grouped specifications
SpecificationsReview condition and scopeLONGiLR7-54HVB-450MEurope450 WREC GroupREC410AA Pure-RAustralia / New Zealand410 W
Electrical · standard test conditions
Rated power
ⓘ

Laboratory DC nameplate power; this is not an annual energy estimate.

450 W
Evidence
Source ↗ PDF page 2, STC 450 W column 2, power rowSTCScope exact_model_columnSource unit WRevision Not verifiedChecked 2026-10-02
410 W
Physical specifications
Length
ⓘ

Nominal manufacturer dimension.

1800 mm
Evidence
Source ↗ PDF page 2, family length rowManufacturer nominal family ratingScope familySource unit mmRevision Not verifiedChecked 2026-10-02
1730 mm
Width
ⓘ

Nominal manufacturer dimension.

1134 mm
Evidence
Source ↗ PDF page 2, family width rowManufacturer nominal family ratingScope familySource unit mmRevision Not verifiedChecked 2026-10-02
1118 mm
Thickness
ⓘ

Unknown thickness is never inferred from a nearby model.

30 mm
Evidence
Source ↗ PDF page 2, family thickness rowManufacturer nominal family ratingScope familySource unit mmRevision Not verifiedChecked 2026-10-02
30 mm
Cell technology
ⓘ

Shown only when this field has passed integration review.

Back-contact cells
Evidence
Source ↗ PDF page 2, family technology rowManufacturer nominal family ratingScope familyRevision Not verifiedChecked 2026-10-02
Not verified
Module type
ⓘ

Bifacial modules can receive light on both faces; this is not a yield prediction.

Not verified Not verified
Weight
ⓘ

Nominal weight for this documented construction.

21.6 kg
Evidence
Source ↗ PDF page 2, family weight rowManufacturer nominal family ratingScope familySource unit kgRevision Not verifiedChecked 2026-10-02
Not verified
Temperature & warranty
Power temperature coefficient
ⓘ

Change in rated power per degree; sign and test basis matter.

-0.26 %/°C
Evidence
Source ↗ PDF page 2, family temperature rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision Not verifiedChecked 2026-10-02
Not verified
Voltage temperature coefficient
ⓘ

Required for temperature-corrected voltage calculations.

-0.2 %/°C
Evidence
Source ↗ PDF page 2, family temperature_voc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision Not verifiedChecked 2026-10-02
Not verified
Current temperature coefficient
ⓘ

Manufacturer coefficient under its stated test conditions.

0.05 %/°C
Evidence
Source ↗ PDF page 2, family temperature_isc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision Not verifiedChecked 2026-10-02
Not verified
Nominal module operating temperature
ⓘ

NMOT is distinct from STC cell temperature.

Not verified Not verified
Nominal operating cell temperature
ⓘ

NOCT is not substituted for NMOT.

45 °C
Evidence
Source ↗ PDF page 2, family noct rowNominal operating cell temperature, +/-2 degrees CScope familySource unit °CRevision Not verifiedChecked 2026-10-02
Not verified
Maximum system voltage
ⓘ

A module rating, not approval of a proposed string.

1500 V
Evidence
Source ↗ PDF page 2, family max_system_voltage rowManufacturer nominal family ratingScope familySource unit VRevision Not verifiedChecked 2026-10-02
Not verified
Maximum series fuse rating
ⓘ

Installation protection still requires a separate design review.

25 A
Evidence
Source ↗ PDF page 2, family series_fuse rowManufacturer nominal family ratingScope familySource unit ARevision Not verifiedChecked 2026-10-02
Not verified
Power bifaciality
ⓘ

Rear/front power ratio under the documented condition, not a production uplift.

Not verified Not verified
Minimum operating temperature
ⓘ

Manufacturer operating range; not ambient design temperature.

-40 °C
Evidence
Source ↗ PDF page 2, family operating_min rowManufacturer nominal family ratingScope familySource unit °CRevision Not verifiedChecked 2026-10-02
Not verified
Maximum operating temperature
ⓘ

Observe the stated qualifications, including short-term limits.

85 °C
Evidence
Source ↗ PDF page 2, family operating_max rowManufacturer nominal family ratingScope familySource unit °CRevision Not verifiedChecked 2026-10-02
Not verified
Warranty terms
ⓘ

Eligibility and market-specific conditions must be reviewed.

Not verified Not verified
Identity & evidence
Market scope
ⓘ

Different market variants are not assumed interchangeable.

Europe Australia / New Zealand
Product family
ⓘ

The family label does not establish equivalence.

EcoLife Anti-Glare Pro LR7-54HVB REC Alpha Pure-R
Datasheet revision
ⓘ

Specifications can change between document revisions.

Not verified V4.2
Datasheet date
ⓘ

Unknown when not established in the approved record.

Not verified 2025-10
Source verification date
ⓘ

Date recorded in the source evidence.

2026-10-01 2026-10-01
Last integration check
ⓘ

Date of the independent import review.

2026-10-01 2026-10-01
Official sourceDatasheet ↗

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Reviewed archived document ↗Exact document hash 533c0aa86de8… · Printed revision unavailable

Datasheet ↗

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Specs can vary by market/revision. These are equipment specifications, not an electrical compatibility verdict. Module voltage is not household voltage. Installation suitability requires a separate professional assessment.