SIDE BY SIDE, SOURCE BY SOURCE
Small details.
Clear differences.
Compare exact models without a universal winner.
Different market variants are not assumed interchangeable.
Technical specifications incomplete
Deep electrical comparison requires reviewed core fields and consistent STC values for every selected model. Review the reasons below and the exact source documents.
- REC600AA Pro MG · Australia / New Zealand
missing reviewed power, voc, vmp, isc, imp, temperature.
Highlighted rows differ in value, unit, test condition or rating scope. “Not verified” is an unknown, never zero. On small screens, scroll the table sideways.
| SpecificationsReview condition and scope | Canadian Solar / CSI SolarCS6.2-66TB-615Australia615 W | REC GroupREC600AA Pro MGAustralia / New Zealand600 W |
|---|---|---|
| Electrical · standard test conditions | ||
Rated powerⓘLaboratory DC nameplate power; this is not an annual energy estimate. | 615 W
EvidenceSource ↗
PDF page 2, STC table, exact CS6.2-66TB-615 row, power column 2 (model identifier is column 1)STCScope exact_model_columnSource unit WRevision V1.5_AUChecked 2026-10-02 | 600 W |
| Physical specifications | ||
LengthⓘNominal manufacturer dimension. | 2382 mm
EvidenceSource ↗
PDF page 2, family length rowManufacturer nominal family ratingScope familySource unit mmRevision V1.5_AUChecked 2026-10-02 | 2175 mm |
WidthⓘNominal manufacturer dimension. | 1134 mm
EvidenceSource ↗
PDF page 2, family width rowManufacturer nominal family ratingScope familySource unit mmRevision V1.5_AUChecked 2026-10-02 | 1305 mm |
ThicknessⓘUnknown thickness is never inferred from a nearby model. | 30 mm
EvidenceSource ↗
PDF page 2, family thickness rowManufacturer nominal family ratingScope familySource unit mmRevision V1.5_AUChecked 2026-10-02 | 30 mm |
Cell technologyⓘShown only when this field has passed integration review. | Not verified | Not verified |
Module typeⓘBifacial modules can receive light on both faces; this is not a yield prediction. | Not verified | Not verified |
WeightⓘNominal weight for this documented construction. | 32.8 kg
EvidenceSource ↗
PDF page 2, family weight rowManufacturer nominal family ratingScope familySource unit kgRevision V1.5_AUChecked 2026-10-02 | Not verified |
| Temperature & warranty | ||
Power temperature coefficientⓘChange in rated power per degree; sign and test basis matter. | -0.29 %/°C
EvidenceSource ↗
PDF page 2, family temperature rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision V1.5_AUChecked 2026-10-02 | Not verified |
Voltage temperature coefficientⓘRequired for temperature-corrected voltage calculations. | -0.25 %/°C
EvidenceSource ↗
PDF page 2, family temperature_voc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision V1.5_AUChecked 2026-10-02 | Not verified |
Current temperature coefficientⓘManufacturer coefficient under its stated test conditions. | 0.045 %/°C
EvidenceSource ↗
PDF page 2, family temperature_isc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision V1.5_AUChecked 2026-10-02 | Not verified |
Nominal module operating temperatureⓘNMOT is distinct from STC cell temperature. | 41 °C
EvidenceSource ↗
PDF page 2, family nmot rowNMOT nominal, +/-3 degrees CScope familySource unit °CRevision V1.5_AUChecked 2026-10-02 | Not verified |
Nominal operating cell temperatureⓘNOCT is not substituted for NMOT. | Not verified | Not verified |
Maximum system voltageⓘA module rating, not approval of a proposed string. | 1500 V
EvidenceSource ↗
PDF page 2, family max_system_voltage rowManufacturer nominal family ratingScope familySource unit VRevision V1.5_AUChecked 2026-10-02 | Not verified |
Maximum series fuse ratingⓘInstallation protection still requires a separate design review. | 35 A
EvidenceSource ↗
PDF page 2, family series_fuse rowManufacturer nominal family ratingScope familySource unit ARevision V1.5_AUChecked 2026-10-02 | Not verified |
Power bifacialityⓘRear/front power ratio under the documented condition, not a production uplift. | 80 %
EvidenceSource ↗
PDF page 2, family bifaciality rowPmax rear / Pmax front at STC, tolerance +/-5 percentage pointsScope familySource unit %Revision V1.5_AUChecked 2026-10-02 | Not verified |
Minimum operating temperatureⓘManufacturer operating range; not ambient design temperature. | -40 °C
EvidenceSource ↗
PDF page 2, family operating_min rowManufacturer nominal family ratingScope familySource unit °CRevision V1.5_AUChecked 2026-10-02 | Not verified |
Maximum operating temperatureⓘObserve the stated qualifications, including short-term limits. | 85 °C
EvidenceSource ↗
PDF page 2, family operating_max rowManufacturer nominal family ratingScope familySource unit °CRevision V1.5_AUChecked 2026-10-02 | Not verified |
Warranty termsⓘEligibility and market-specific conditions must be reviewed. | Not verified | Not verified |
| Identity & evidence | ||
Market scopeⓘDifferent market variants are not assumed interchangeable. | Australia | Australia / New Zealand |
Product familyⓘThe family label does not establish equivalence. | TOPBiHiKu6 | REC Alpha Pro MG |
Datasheet revisionⓘSpecifications can change between document revisions. | V1.5_AU | V4.9 |
Datasheet dateⓘUnknown when not established in the approved record. | 2025-08 | 2025-10 |
Source verification dateⓘDate recorded in the source evidence. | 2026-10-01 | 2026-10-01 |
Last integration checkⓘDate of the independent import review. | 2026-10-01 | 2026-10-01 |
| Official source | Datasheet ↗ Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | Datasheet ↗ Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
Specs can vary by market/revision. These are equipment specifications, not an electrical compatibility verdict. Module voltage is not household voltage. Installation suitability requires a separate professional assessment.