| SpecificationsReview condition and scope | JinkoSolarJKM620N-66HL4M-BDVJapan620 W | LONGiLR7-60HVD-550MEurope / Global download550 W |
|---|---|---|
| Electrical · standard test conditions | ||
Rated powerⓘLaboratory DC nameplate power; this is not an annual energy estimate. | 620 W
EvidenceSource ↗
PDF page 2, STC 620 W column 4, power rowSTCScope exact_model_columnSource unit WRevision F4-JPChecked 2026-10-02 | 550 W
EvidenceSource ↗
PDF page 2, STC 550 W column 5, power rowSTCScope exact_model_columnSource unit WRevision Not verifiedChecked 2026-10-02 |
Open-circuit voltageⓘModule voltage without a load. It is not household voltage. | 49.08 V
EvidenceSource ↗
PDF page 2, STC 620 W column 4, voc rowSTCScope exact_model_columnSource unit VRevision F4-JPChecked 2026-10-02 | 45.35 V
EvidenceSource ↗
PDF page 2, STC 550 W column 5, voc rowSTCScope exact_model_columnSource unit VRevision Not verifiedChecked 2026-10-02 |
Voltage at maximum powerⓘModule operating voltage at STC. | 40.74 V
EvidenceSource ↗
PDF page 2, STC 620 W column 4, vmp rowSTCScope exact_model_columnSource unit VRevision F4-JPChecked 2026-10-02 | 37.57 V
EvidenceSource ↗
PDF page 2, STC 550 W column 5, vmp rowSTCScope exact_model_columnSource unit VRevision Not verifiedChecked 2026-10-02 |
Short-circuit currentⓘModule current under the stated test condition. | 16.08 A
EvidenceSource ↗
PDF page 2, STC 620 W column 4, isc rowSTCScope exact_model_columnSource unit ARevision F4-JPChecked 2026-10-02 | 15.3 A
EvidenceSource ↗
PDF page 2, STC 550 W column 5, isc rowSTCScope exact_model_columnSource unit ARevision Not verifiedChecked 2026-10-02 |
Current at maximum powerⓘModule operating current at STC. | 15.22 A
EvidenceSource ↗
PDF page 2, STC 620 W column 4, imp rowSTCScope exact_model_columnSource unit ARevision F4-JPChecked 2026-10-02 | 14.64 A
EvidenceSource ↗
PDF page 2, STC 550 W column 5, imp rowSTCScope exact_model_columnSource unit ARevision Not verifiedChecked 2026-10-02 |
Module efficiencyⓘExact STC power column, not bifacial rear-side gain. | 22.95 %
EvidenceSource ↗
PDF page 2, STC 620 W column 4, efficiency rowSTCScope exact_model_columnSource unit %Revision F4-JPChecked 2026-10-02 | 24.4 %
EvidenceSource ↗
PDF page 2, STC 550 W column 5, efficiency rowSTCScope exact_model_columnSource unit %Revision Not verifiedChecked 2026-10-02 |
| Physical specifications | ||
LengthⓘNominal manufacturer dimension. | 2382 mm
EvidenceSource ↗
PDF page 2, family length rowManufacturer nominal family ratingScope familySource unit mmRevision F4-JPChecked 2026-10-02 | 1990 mm
EvidenceSource ↗
PDF page 2, family length rowManufacturer nominal family ratingScope familySource unit mmRevision Not verifiedChecked 2026-10-02 |
WidthⓘNominal manufacturer dimension. | 1134 mm
EvidenceSource ↗
PDF page 2, family width rowManufacturer nominal family ratingScope familySource unit mmRevision F4-JPChecked 2026-10-02 | 1134 mm
EvidenceSource ↗
PDF page 2, family width rowManufacturer nominal family ratingScope familySource unit mmRevision Not verifiedChecked 2026-10-02 |
ThicknessⓘUnknown thickness is never inferred from a nearby model. | 30 mm
EvidenceSource ↗
PDF page 2, family thickness rowManufacturer nominal family ratingScope familySource unit mmRevision F4-JPChecked 2026-10-02 | 30 mm
EvidenceSource ↗
PDF page 2, family thickness rowManufacturer nominal family ratingScope familySource unit mmRevision Not verifiedChecked 2026-10-02 |
Cell technologyⓘShown only when this field has passed integration review. | Not verified | Back-contact cells
EvidenceSource ↗
PDF page 2, family technology rowManufacturer nominal family ratingScope familyRevision Not verifiedChecked 2026-10-02 |
Module typeⓘBifacial modules can receive light on both faces; this is not a yield prediction. | Not verified | Not verified |
WeightⓘNominal weight for this documented construction. | 32.4 kg
EvidenceSource ↗
PDF page 2, family weight rowManufacturer nominal family ratingScope familySource unit kgRevision F4-JPChecked 2026-10-02 | 28 kg
EvidenceSource ↗
PDF page 2, family weight rowManufacturer nominal family ratingScope familySource unit kgRevision Not verifiedChecked 2026-10-02 |
| Temperature & warranty | ||
Power temperature coefficientⓘChange in rated power per degree; sign and test basis matter. | -0.29 %/°C
EvidenceSource ↗
PDF page 2, family temperature rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision F4-JPChecked 2026-10-02 | -0.26 %/°C
EvidenceSource ↗
PDF page 2, family temperature rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision Not verifiedChecked 2026-10-02 |
Voltage temperature coefficientⓘRequired for temperature-corrected voltage calculations. | -0.25 %/°C
EvidenceSource ↗
PDF page 2, family temperature_voc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision F4-JPChecked 2026-10-02 | -0.2 %/°C
EvidenceSource ↗
PDF page 2, family temperature_voc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision Not verifiedChecked 2026-10-02 |
Current temperature coefficientⓘManufacturer coefficient under its stated test conditions. | 0.045 %/°C
EvidenceSource ↗
PDF page 2, family temperature_isc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision F4-JPChecked 2026-10-02 | 0.05 %/°C
EvidenceSource ↗
PDF page 2, family temperature_isc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision Not verifiedChecked 2026-10-02 |
Nominal module operating temperatureⓘNMOT is distinct from STC cell temperature. | Not verified | Not verified |
Nominal operating cell temperatureⓘNOCT is not substituted for NMOT. | Not verified | 45 °C
EvidenceSource ↗
PDF page 2, family noct rowNominal operating cell temperature, +/-2 degrees CScope familySource unit °CRevision Not verifiedChecked 2026-10-02 |
Maximum system voltageⓘA module rating, not approval of a proposed string. | 1500 V
EvidenceSource ↗
PDF page 2, family max_system_voltage rowManufacturer nominal family ratingScope familySource unit VRevision F4-JPChecked 2026-10-02 | 1500 V
EvidenceSource ↗
PDF page 2, family max_system_voltage rowManufacturer nominal family ratingScope familySource unit VRevision Not verifiedChecked 2026-10-02 |
Maximum series fuse ratingⓘInstallation protection still requires a separate design review. | 35 A
EvidenceSource ↗
PDF page 2, family series_fuse rowManufacturer nominal family ratingScope familySource unit ARevision F4-JPChecked 2026-10-02 | 30 A
EvidenceSource ↗
PDF page 2, family series_fuse rowManufacturer nominal family ratingScope familySource unit ARevision Not verifiedChecked 2026-10-02 |
Power bifacialityⓘRear/front power ratio under the documented condition, not a production uplift. | Not verified | Not verified |
Minimum operating temperatureⓘManufacturer operating range; not ambient design temperature. | Not verified | -40 °C
EvidenceSource ↗
PDF page 2, family operating_min rowManufacturer nominal family ratingScope familySource unit °CRevision Not verifiedChecked 2026-10-02 |
Maximum operating temperatureⓘObserve the stated qualifications, including short-term limits. | Not verified | 85 °C
EvidenceSource ↗
PDF page 2, family operating_max rowManufacturer nominal family ratingScope familySource unit °CRevision Not verifiedChecked 2026-10-02 |
Warranty termsⓘEligibility and market-specific conditions must be reviewed. | Not verified | Not verified |
| Identity & evidence | ||
Market scopeⓘDifferent market variants are not assumed interchangeable. | Japan | Europe / Global download |
Product familyⓘThe family label does not establish equivalence. | Tiger Neo Series — JKM605-630W66HL4-BDV-J | Hi-MO X10 Scientist |
Datasheet revisionⓘSpecifications can change between document revisions. | F4-JP | Not verified |
Datasheet dateⓘUnknown when not established in the approved record. | Not verified | Not verified |
Source verification dateⓘDate recorded in the source evidence. | 2026-10-01 | 2026-10-01 |
Last integration checkⓘDate of the independent import review. | 2026-10-01 | 2026-10-01 |
| Official source | Datasheet ↗ Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | Datasheet ↗ Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 Reviewed archived document ↗Exact document hash aab37533eba1… · Printed revision unavailable |
Specs can vary by market/revision. These are equipment specifications, not an electrical compatibility verdict. Module voltage is not household voltage. Installation suitability requires a separate professional assessment.