PUBLIC CATALOGUE • 1124 solar panel records. Technical coverage is shown separately.

SIDE BY SIDE, SOURCE BY SOURCE

Small details.
Clear differences.

Compare exact models without a universal winner.
Different market variants are not assumed interchangeable.

Edit selection

Highlighted rows differ in value, unit, test condition or rating scope. “Not verified” is an unknown, never zero. On small screens, scroll the table sideways.

2 exact models, grouped specifications
SpecificationsReview condition and scopeCanadian Solar / CSI SolarCS6.2-66TB-625HRNorth America625 WCanadian Solar / CSI SolarCS6.3-66TB-655Global / APAC reference655 W
Electrical · standard test conditions
Rated power
ⓘ

Laboratory DC nameplate power; this is not an annual energy estimate.

625 W
Evidence
Source ↗ PDF page 2, STC table, exact CS6.2-66TB-625HR row, power column 2 (model identifier is column 1)STCScope exact_model_columnSource unit WRevision V1.4_F68_L1_600-625_TXChecked 2026-10-02
655 W
Evidence
Source ↗ PDF page 2, STC table, exact CS6.3-66TB-655 row, power column 2 (model identifier is column 1)STCScope exact_model_columnSource unit WRevision V1.11_ENChecked 2026-10-02
Open-circuit voltage
ⓘ

Module voltage without a load. It is not household voltage.

49.9 V
Evidence
Source ↗ PDF page 2, STC table, exact CS6.2-66TB-625HR row, voc column 5 (model identifier is column 1)STCScope exact_model_columnSource unit VRevision V1.4_F68_L1_600-625_TXChecked 2026-10-02
50.2 V
Evidence
Source ↗ PDF page 2, STC table, exact CS6.3-66TB-655 row, voc column 5 (model identifier is column 1)STCScope exact_model_columnSource unit VRevision V1.11_ENChecked 2026-10-02
Voltage at maximum power
ⓘ

Module operating voltage at STC.

43.2 V
Evidence
Source ↗ PDF page 2, STC table, exact CS6.2-66TB-625HR row, vmp column 3 (model identifier is column 1)STCScope exact_model_columnSource unit VRevision V1.4_F68_L1_600-625_TXChecked 2026-10-02
42.7 V
Evidence
Source ↗ PDF page 2, STC table, exact CS6.3-66TB-655 row, vmp column 3 (model identifier is column 1)STCScope exact_model_columnSource unit VRevision V1.11_ENChecked 2026-10-02
Short-circuit current
ⓘ

Module current under the stated test condition.

15.62 A
Evidence
Source ↗ PDF page 2, STC table, exact CS6.2-66TB-625HR row, isc column 6 (model identifier is column 1)STCScope exact_model_columnSource unit ARevision V1.4_F68_L1_600-625_TXChecked 2026-10-02
16.25 A
Evidence
Source ↗ PDF page 2, STC table, exact CS6.3-66TB-655 row, isc column 6 (model identifier is column 1)STCScope exact_model_columnSource unit ARevision V1.11_ENChecked 2026-10-02
Current at maximum power
ⓘ

Module operating current at STC.

14.49 A
Evidence
Source ↗ PDF page 2, STC table, exact CS6.2-66TB-625HR row, imp column 4 (model identifier is column 1)STCScope exact_model_columnSource unit ARevision V1.4_F68_L1_600-625_TXChecked 2026-10-02
15.36 A
Evidence
Source ↗ PDF page 2, STC table, exact CS6.3-66TB-655 row, imp column 4 (model identifier is column 1)STCScope exact_model_columnSource unit ARevision V1.11_ENChecked 2026-10-02
Module efficiency
ⓘ

Exact STC power column, not bifacial rear-side gain.

23.1 %
Evidence
Source ↗ PDF page 2, STC table, exact CS6.2-66TB-625HR row, efficiency column 7 (model identifier is column 1)STCScope exact_model_columnSource unit %Revision V1.4_F68_L1_600-625_TXChecked 2026-10-02
24.2 %
Evidence
Source ↗ PDF page 2, STC table, exact CS6.3-66TB-655 row, efficiency column 7 (model identifier is column 1)STCScope exact_model_columnSource unit %Revision V1.11_ENChecked 2026-10-02
Physical specifications
Length
ⓘ

Nominal manufacturer dimension.

2382 mm
Evidence
Source ↗ PDF page 2, family length rowManufacturer nominal family ratingScope familySource unit mmRevision V1.4_F68_L1_600-625_TXChecked 2026-10-02
2382 mm
Evidence
Source ↗ PDF page 2, family length rowManufacturer nominal family ratingScope familySource unit mmRevision V1.11_ENChecked 2026-10-02
Width
ⓘ

Nominal manufacturer dimension.

1134 mm
Evidence
Source ↗ PDF page 2, family width rowManufacturer nominal family ratingScope familySource unit mmRevision V1.4_F68_L1_600-625_TXChecked 2026-10-02
1134 mm
Evidence
Source ↗ PDF page 2, family width rowManufacturer nominal family ratingScope familySource unit mmRevision V1.11_ENChecked 2026-10-02
Thickness
ⓘ

Unknown thickness is never inferred from a nearby model.

40 mm
Evidence
Source ↗ PDF page 2, family thickness rowManufacturer nominal family ratingScope familySource unit mmRevision V1.4_F68_L1_600-625_TXChecked 2026-10-02
30 mm
Evidence
Source ↗ PDF page 2, family thickness rowManufacturer nominal family ratingScope familySource unit mmRevision V1.11_ENChecked 2026-10-02
Cell technology
ⓘ

Shown only when this field has passed integration review.

Not verified Not verified
Module type
ⓘ

Bifacial modules can receive light on both faces; this is not a yield prediction.

Not verified Not verified
Weight
ⓘ

Nominal weight for this documented construction.

33.4 kg
Evidence
Source ↗ PDF page 2, family weight rowManufacturer nominal family ratingScope familySource unit kgRevision V1.4_F68_L1_600-625_TXChecked 2026-10-02
32.8 kg
Evidence
Source ↗ PDF page 2, family weight rowManufacturer nominal family ratingScope familySource unit kgRevision V1.11_ENChecked 2026-10-02
Temperature & warranty
Power temperature coefficient
ⓘ

Change in rated power per degree; sign and test basis matter.

-0.29 %/°C
Evidence
Source ↗ PDF page 2, family temperature rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision V1.4_F68_L1_600-625_TXChecked 2026-10-02
-0.26 %/°C
Evidence
Source ↗ PDF page 2, family temperature rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision V1.11_ENChecked 2026-10-02
Voltage temperature coefficient
ⓘ

Required for temperature-corrected voltage calculations.

-0.25 %/°C
Evidence
Source ↗ PDF page 2, family temperature_voc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision V1.4_F68_L1_600-625_TXChecked 2026-10-02
-0.22 %/°C
Evidence
Source ↗ PDF page 2, family temperature_voc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision V1.11_ENChecked 2026-10-02
Current temperature coefficient
ⓘ

Manufacturer coefficient under its stated test conditions.

0.045 %/°C
Evidence
Source ↗ PDF page 2, family temperature_isc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision V1.4_F68_L1_600-625_TXChecked 2026-10-02
0.045 %/°C
Evidence
Source ↗ PDF page 2, family temperature_isc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision V1.11_ENChecked 2026-10-02
Nominal module operating temperature
ⓘ

NMOT is distinct from STC cell temperature.

41 °C
Evidence
Source ↗ PDF page 2, family nmot rowNMOT nominal, +/-3 degrees CScope familySource unit °CRevision V1.4_F68_L1_600-625_TXChecked 2026-10-02
41 °C
Evidence
Source ↗ PDF page 2, family nmot rowNMOT nominal, +/-3 degrees CScope familySource unit °CRevision V1.11_ENChecked 2026-10-02
Nominal operating cell temperature
ⓘ

NOCT is not substituted for NMOT.

Not verified Not verified
Maximum system voltage
ⓘ

A module rating, not approval of a proposed string.

1500 V
Evidence
Source ↗ PDF page 2, family max_system_voltage rowManufacturer nominal family ratingScope familySource unit VRevision V1.4_F68_L1_600-625_TXChecked 2026-10-02
1500 V
Evidence
Source ↗ PDF page 2, family max_system_voltage rowManufacturer nominal family ratingScope familySource unit VRevision V1.11_ENChecked 2026-10-02
Maximum series fuse rating
ⓘ

Installation protection still requires a separate design review.

35 A
Evidence
Source ↗ PDF page 2, family series_fuse rowManufacturer nominal family ratingScope familySource unit ARevision V1.4_F68_L1_600-625_TXChecked 2026-10-02
35 A
Evidence
Source ↗ PDF page 2, family series_fuse rowManufacturer nominal family ratingScope familySource unit ARevision V1.11_ENChecked 2026-10-02
Power bifaciality
ⓘ

Rear/front power ratio under the documented condition, not a production uplift.

Not verified 85 %
Evidence
Source ↗ PDF page 2, family bifaciality rowPmax rear / Pmax front, both at STC; +/-5 percentage pointsScope familySource unit %Revision V1.11_ENChecked 2026-10-02
Minimum operating temperature
ⓘ

Manufacturer operating range; not ambient design temperature.

-40 °C
Evidence
Source ↗ PDF page 2, family operating_min rowManufacturer nominal family ratingScope familySource unit °CRevision V1.4_F68_L1_600-625_TXChecked 2026-10-02
-40 °C
Evidence
Source ↗ PDF page 2, family operating_min rowManufacturer nominal family ratingScope familySource unit °CRevision V1.11_ENChecked 2026-10-02
Maximum operating temperature
ⓘ

Observe the stated qualifications, including short-term limits.

85 °C
Evidence
Source ↗ PDF page 2, family operating_max rowManufacturer nominal family ratingScope familySource unit °CRevision V1.4_F68_L1_600-625_TXChecked 2026-10-02
85 °C
Evidence
Source ↗ PDF page 2, family operating_max rowManufacturer nominal family ratingScope familySource unit °CRevision V1.11_ENChecked 2026-10-02
Warranty terms
ⓘ

Eligibility and market-specific conditions must be reviewed.

Not verified Not verified
Identity & evidence
Market scope
ⓘ

Different market variants are not assumed interchangeable.

North America Global / APAC reference
Product family
ⓘ

The family label does not establish equivalence.

TOPBiHiKu6 TOPBiHiKu6 / TOPCon Gen3 182 Pro
Datasheet revision
ⓘ

Specifications can change between document revisions.

V1.4_F68_L1_600-625_TX V1.11_EN
Datasheet date
ⓘ

Unknown when not established in the approved record.

2026-09 2026-06
Source verification date
ⓘ

Date recorded in the source evidence.

2026-10-01 2026-10-01
Last integration check
ⓘ

Date of the independent import review.

2026-10-01 2026-10-01
Official sourceDatasheet ↗

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Datasheet ↗

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Specs can vary by market/revision. These are equipment specifications, not an electrical compatibility verdict. Module voltage is not household voltage. Installation suitability requires a separate professional assessment.