PUBLIC CATALOGUE • 1124 solar panel records. Technical coverage is shown separately.

SIDE BY SIDE, SOURCE BY SOURCE

Small details.
Clear differences.

Compare exact models without a universal winner.
Different market variants are not assumed interchangeable.

Edit selection

Highlighted rows differ in value, unit, test condition or rating scope. “Not verified” is an unknown, never zero. On small screens, scroll the table sideways.

2 exact models, grouped specifications
SpecificationsReview condition and scopeJA SolarJAM72D40-600/MBGlobal600 WJinkoSolarJKM420N-54HL4-BUSA420 W
Electrical · standard test conditions
Rated power
ⓘ

Laboratory DC nameplate power; this is not an annual energy estimate.

600 W
Evidence
Source ↗ ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSSTCScope exact_model_columnSource unit WRevision Global-EN-20241105AChecked 2026-10-02
420 W
Evidence
Source ↗ PDF page 2, Electrical Characteristics (STC), exact JKM420N-54HL4-B / 420 W column 1, Pmax rowSTCScope exact_model_columnSource unit WRevision F2-USChecked 2026-10-02
Open-circuit voltage
ⓘ

Module voltage without a load. It is not household voltage.

52.79 V
Evidence
Source ↗ ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSSTCScope exact_model_columnSource unit VRevision Global-EN-20241105AChecked 2026-10-02
38.74 V
Evidence
Source ↗ PDF page 2, Electrical Characteristics (STC), exact JKM420N-54HL4-B / 420 W column 1, Voc rowSTCScope exact_model_columnSource unit VRevision F2-USChecked 2026-10-02
Voltage at maximum power
ⓘ

Module operating voltage at STC.

44.85 V
Evidence
Source ↗ ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSSTCScope exact_model_columnSource unit VRevision Global-EN-20241105AChecked 2026-10-02
32.16 V
Evidence
Source ↗ PDF page 2, Electrical Characteristics (STC), exact JKM420N-54HL4-B / 420 W column 1, Vmp rowSTCScope exact_model_columnSource unit VRevision F2-USChecked 2026-10-02
Short-circuit current
ⓘ

Module current under the stated test condition.

14.04 A
Evidence
Source ↗ ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSSTCScope exact_model_columnSource unit ARevision Global-EN-20241105AChecked 2026-10-02
13.51 A
Evidence
Source ↗ PDF page 2, Electrical Characteristics (STC), exact JKM420N-54HL4-B / 420 W column 1, Isc rowSTCScope exact_model_columnSource unit ARevision F2-USChecked 2026-10-02
Current at maximum power
ⓘ

Module operating current at STC.

13.38 A
Evidence
Source ↗ ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSSTCScope exact_model_columnSource unit ARevision Global-EN-20241105AChecked 2026-10-02
13.06 A
Evidence
Source ↗ PDF page 2, Electrical Characteristics (STC), exact JKM420N-54HL4-B / 420 W column 1, Imp rowSTCScope exact_model_columnSource unit ARevision F2-USChecked 2026-10-02
Module efficiency
ⓘ

Exact STC power column, not bifacial rear-side gain.

23.2 %
Evidence
Source ↗ ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSSTCScope exact_model_columnSource unit %Revision Global-EN-20241105AChecked 2026-10-02
21.51 %
Evidence
Source ↗ PDF page 2, Electrical Characteristics (STC), exact JKM420N-54HL4-B / 420 W column 1, Module efficiency rowSTCScope exact_model_columnSource unit %Revision F2-USChecked 2026-10-02
Physical specifications
Length
ⓘ

Nominal manufacturer dimension.

2278 mm
Evidence
Source ↗ ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit mmRevision Global-EN-20241105AChecked 2026-10-02
1722 mm
Evidence
Source ↗ PDF page 2, Mechanical / temperature / operating characteristics, shared family length rowManufacturer nominal family ratingScope familySource unit mmRevision F2-USChecked 2026-10-02
Width
ⓘ

Nominal manufacturer dimension.

1134 mm
Evidence
Source ↗ ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit mmRevision Global-EN-20241105AChecked 2026-10-02
1134 mm
Evidence
Source ↗ PDF page 2, Mechanical / temperature / operating characteristics, shared family width rowManufacturer nominal family ratingScope familySource unit mmRevision F2-USChecked 2026-10-02
Thickness
ⓘ

Unknown thickness is never inferred from a nearby model.

30 mm
Evidence
Source ↗ ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit mmRevision Global-EN-20241105AChecked 2026-10-02
35 mm
Evidence
Source ↗ PDF page 2, Mechanical / temperature / operating characteristics, shared family thickness rowManufacturer nominal family ratingScope familySource unit mmRevision F2-USChecked 2026-10-02
Cell technology
ⓘ

Shown only when this field has passed integration review.

Not verified N-type TOPCon monocrystalline
Evidence
Source ↗ PDF page 1, product identity / technology statementManufacturer-stated cell/module technologyScope familyRevision F2-USChecked 2026-10-02
Module type
ⓘ

Bifacial modules can receive light on both faces; this is not a yield prediction.

Not verified monofacial
Evidence
Source ↗ PDF page 1 and/or official regional product description, face/construction statementManufacturer-stated or explicitly described module constructionScope familyRevision F2-USChecked 2026-10-02
Weight
ⓘ

Nominal weight for this documented construction.

31.8 kg
Evidence
Source ↗ ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit kgRevision Global-EN-20241105AChecked 2026-10-02
21 kg
Evidence
Source ↗ PDF page 2, Mechanical / temperature / operating characteristics, shared family weight rowManufacturer nominal family ratingScope familySource unit kgRevision F2-USChecked 2026-10-02
Temperature & warranty
Power temperature coefficient
ⓘ

Change in rated power per degree; sign and test basis matter.

-0.29 %/°C
Evidence
Source ↗ ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit %/°CRevision Global-EN-20241105AChecked 2026-10-02
-0.29 %/°C
Evidence
Source ↗ PDF page 2, Mechanical / temperature / operating characteristics, shared family temperature rowManufacturer family Pmax temperature coefficient, STC referenceScope familySource unit %/°CRevision F2-USChecked 2026-10-02
Voltage temperature coefficient
ⓘ

Required for temperature-corrected voltage calculations.

-0.25 %/°C
Evidence
Source ↗ ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit %/°CRevision Global-EN-20241105AChecked 2026-10-02
-0.25 %/°C
Evidence
Source ↗ PDF page 2, Mechanical / temperature / operating characteristics, shared family temperature_voc rowManufacturer family Voc temperature coefficient, STC referenceScope familySource unit %/°CRevision F2-USChecked 2026-10-02
Current temperature coefficient
ⓘ

Manufacturer coefficient under its stated test conditions.

0.045 %/°C
Evidence
Source ↗ ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit %/°CRevision Global-EN-20241105AChecked 2026-10-02
0.045 %/°C
Evidence
Source ↗ PDF page 2, Mechanical / temperature / operating characteristics, shared family temperature_isc rowManufacturer family Isc temperature coefficient, STC referenceScope familySource unit %/°CRevision F2-USChecked 2026-10-02
Nominal module operating temperature
ⓘ

NMOT is distinct from STC cell temperature.

Not verified Not verified
Nominal operating cell temperature
ⓘ

NOCT is not substituted for NMOT.

45 °C
Evidence
Source ↗ ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit °CRevision Global-EN-20241105AChecked 2026-10-02
45 °C
Evidence
Source ↗ PDF page 2, Mechanical / temperature / operating characteristics, shared family noct rowNOCT, manufacturer value; ±2°C tolerance where statedScope familySource unit °CRevision F2-USChecked 2026-10-02
Maximum system voltage
ⓘ

A module rating, not approval of a proposed string.

1500 V
Evidence
Source ↗ ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit VRevision Global-EN-20241105AChecked 2026-10-02
1000 V
Evidence
Source ↗ PDF page 2, Mechanical / temperature / operating characteristics, shared family max_system_voltage rowManufacturer nominal family ratingScope familySource unit VRevision F2-USChecked 2026-10-02
Maximum series fuse rating
ⓘ

Installation protection still requires a separate design review.

30 A
Evidence
Source ↗ ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit ARevision Global-EN-20241105AChecked 2026-10-02
25 A
Evidence
Source ↗ PDF page 2, Mechanical / temperature / operating characteristics, shared family series_fuse rowManufacturer nominal family ratingScope familySource unit ARevision F2-USChecked 2026-10-02
Power bifaciality
ⓘ

Rear/front power ratio under the documented condition, not a production uplift.

Not verified Not verified
Minimum operating temperature
ⓘ

Manufacturer operating range; not ambient design temperature.

-40 °C
Evidence
Source ↗ ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit °CRevision Global-EN-20241105AChecked 2026-10-02
-40 °C
Evidence
Source ↗ PDF page 2, Mechanical / temperature / operating characteristics, shared family operating_min rowManufacturer nominal family ratingScope familySource unit °CRevision F2-USChecked 2026-10-02
Maximum operating temperature
ⓘ

Observe the stated qualifications, including short-term limits.

85 °C
Evidence
Source ↗ ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit °CRevision Global-EN-20241105AChecked 2026-10-02
85 °C
Evidence
Source ↗ PDF page 2, Mechanical / temperature / operating characteristics, operating temperature range; nominal upper boundManufacturer nominal family ratingScope familySource unit °CRevision F2-USChecked 2026-10-02
Warranty terms
ⓘ

Eligibility and market-specific conditions must be reviewed.

Not verified 25-year product warranty; 30-year linear power warranty; ≤1% first-year degradation and ≤0.40% annual degradation thereafter; ≥87.4% at year 30.
Evidence
Source ↗ PDF page 2, warranty statement applicable to the familyManufacturer warranty statement / datasheet warranty summaryScope familyRevision F2-USChecked 2026-10-02
Identity & evidence
Market scope
ⓘ

Different market variants are not assumed interchangeable.

Global USA
Product family
ⓘ

The family label does not establish equivalence.

DeepBlue 4.0 Pro EAGLE G6R
Datasheet revision
ⓘ

Specifications can change between document revisions.

Global-EN-20241105A F2-US
Datasheet date
ⓘ

Unknown when not established in the approved record.

2024-11-05 Not verified
Source verification date
ⓘ

Date recorded in the source evidence.

2026-10-02 2026-10-02
Last integration check
ⓘ

Date of the independent import review.

2026-10-02 2026-10-02
Official sourceDatasheet ↗

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Datasheet ↗

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Specs can vary by market/revision. These are equipment specifications, not an electrical compatibility verdict. Module voltage is not household voltage. Installation suitability requires a separate professional assessment.