3 exact models, grouped specifications
SpecificationsSTC · same unitsAIKOAIKO-A460-MAH54MbPakistan460 WAIKOAIKO-A465-MCE54DwPakistan465 WTrinasolarTSM-710NEG21C.20North America710 W
Electrical · standard test conditions
Rated power
ⓘ

Laboratory DC nameplate power; this is not an annual energy estimate.

460 W465 W710 W
Open-circuit voltage
ⓘ

Module voltage without a load. It is not household voltage.

41.06 V40.6 V49 V
Voltage at maximum power
ⓘ

Module operating voltage at STC.

34.62 V34.2 V40.9 V
Short-circuit current
ⓘ

Module current under the stated test condition.

14.25 A14.69 A18.4 A
Current at maximum power
ⓘ

Module operating current at STC.

13.29 A13.6 A17.36 A
Module efficiency
ⓘ

Exact STC power column, not bifacial rear-side gain.

23.1 %Not verified22.9 %
Physical specifications
Length
ⓘ

Nominal manufacturer dimension.

1757 mm1762 mm2384 mm
Width
ⓘ

Nominal manufacturer dimension.

1134 mm1134 mm1303 mm
Thickness
ⓘ

Unknown thickness is never inferred from a nearby model.

30 mm30 mm33 mm
Cell technology
ⓘ

Shown only when this field has passed integration review.

N-type ABCN-Type ABCN-type TOPCon monocrystalline
Module type
ⓘ

Bifacial modules can receive light on both faces; this is not a yield prediction.

Not verifiedNot verifiedbifacial
Weight
ⓘ

Nominal weight for this documented construction.

20.6 kg24.2 kg38.3 kg
Temperature & warranty
Power temperature coefficient
ⓘ

Change in rated power per degree; sign and test basis matter.

-0.26 %/°C-0.26 %/°C-0.29 %/°C
Voltage temperature coefficient
ⓘ

Required for temperature-corrected voltage calculations.

-0.22 %/°C-0.22 %/°C-0.24 %/°C
Current temperature coefficient
ⓘ

Manufacturer coefficient under its stated test conditions.

0.05 %/°C0.05 %/°C0.04 %/°C
Nominal module operating temperature
ⓘ

NMOT is distinct from STC cell temperature.

Not verifiedNot verifiedNot verified
Nominal operating cell temperature
ⓘ

NOCT is not substituted for NMOT.

Not verifiedNot verified43 °C
Maximum system voltage
ⓘ

A module rating, not approval of a proposed string.

1500 V1500 V1500 V
Maximum series fuse rating
ⓘ

Installation protection still requires a separate design review.

25 A30 A35 A
Power bifaciality
ⓘ

Rear/front power ratio under the documented condition, not a production uplift.

Not verifiedNot verified80 %
Minimum operating temperature
ⓘ

Manufacturer operating range; not ambient design temperature.

-40 °C-40 °C-40 °C
Maximum operating temperature
ⓘ

Observe the stated qualifications, including short-term limits.

85 °C70 °C85 °C
Warranty terms
ⓘ

Eligibility and market-specific conditions must be reviewed.

30-year linear power warranty; product warranty and detailed eligibility require the applicable manufacturer warranty statement.Not verified12-year product workmanship warranty; 30-year power warranty; 1% first-year degradation, 0.40% annual degradation thereafter.
Identity & evidence
Market scope
ⓘ

Different market variants are not assumed interchangeable.

PakistanPakistanNorth America
Product family
ⓘ

The family label does not establish equivalence.

NEOSTAR 2S54 Mono-GlassNEOSTAR 3P+54 Dual-GlassVertex N
Datasheet revision
ⓘ

Specifications can change between document revisions.

V4.1_202510_DsDr_EN202601_V3.1_ENTSM_NA_EN_2026_A
Datasheet date
ⓘ

Unknown when not established in the approved record.

2025-102026-01Not verified
Source verification date
ⓘ

Date recorded in the source evidence.

2026-10-012026-10-012026-10-02
Last integration check
ⓘ

Date of the independent import review.

2026-10-012026-10-012026-10-02