SIDE BY SIDE, SOURCE BY SOURCE
Small details.
Clear differences.
Compare exact models without a universal winner.
Different market variants are not assumed interchangeable.
Highlighted rows differ in value, unit, test condition or rating scope. “Not verified” is an unknown, never zero. On small screens, scroll the table sideways.
| SpecificationsReview condition and scope | TrinasolarTSM-425NEG9RH.25North America425 W | TrinasolarTSM-430NEG9R.25Europe430 W |
|---|---|---|
| Electrical · standard test conditions | ||
Rated powerⓘLaboratory DC nameplate power; this is not an annual energy estimate. | 425 W
EvidenceSource ↗
PDF page 2, Electrical Data (STC), exact TSM-425NEG9RH.25 / 425 W column 2, Pmax rowSTCScope exact_model_columnSource unit WRevision TSM_NA_EN_2026_AChecked 2026-10-02 | 430 W
EvidenceSource ↗
PDF page 2, Electrical Data (STC), exact TSM-430NEG9R.25 / 430 W column 1, Pmax rowSTCScope exact_model_columnSource unit WRevision TSM_EN_2025_BChecked 2026-10-02 |
Open-circuit voltageⓘModule voltage without a load. It is not household voltage. | 34.9 V
EvidenceSource ↗
PDF page 2, Electrical Data (STC), exact TSM-425NEG9RH.25 / 425 W column 2, Voc rowSTCScope exact_model_columnSource unit VRevision TSM_NA_EN_2026_AChecked 2026-10-02 | 51.4 V
EvidenceSource ↗
PDF page 2, Electrical Data (STC), exact TSM-430NEG9R.25 / 430 W column 1, Voc rowSTCScope exact_model_columnSource unit VRevision TSM_EN_2025_BChecked 2026-10-02 |
Voltage at maximum powerⓘModule operating voltage at STC. | 28.7 V
EvidenceSource ↗
PDF page 2, Electrical Data (STC), exact TSM-425NEG9RH.25 / 425 W column 2, Vmp rowSTCScope exact_model_columnSource unit VRevision TSM_NA_EN_2026_AChecked 2026-10-02 | 43.2 V
EvidenceSource ↗
PDF page 2, Electrical Data (STC), exact TSM-430NEG9R.25 / 430 W column 1, Vmp rowSTCScope exact_model_columnSource unit VRevision TSM_EN_2025_BChecked 2026-10-02 |
Short-circuit currentⓘModule current under the stated test condition. | 15.68 A
EvidenceSource ↗
PDF page 2, Electrical Data (STC), exact TSM-425NEG9RH.25 / 425 W column 2, Isc rowSTCScope exact_model_columnSource unit ARevision TSM_NA_EN_2026_AChecked 2026-10-02 | 10.59 A
EvidenceSource ↗
PDF page 2, Electrical Data (STC), exact TSM-430NEG9R.25 / 430 W column 1, Isc rowSTCScope exact_model_columnSource unit ARevision TSM_EN_2025_BChecked 2026-10-02 |
Current at maximum powerⓘModule operating current at STC. | 14.81 A
EvidenceSource ↗
PDF page 2, Electrical Data (STC), exact TSM-425NEG9RH.25 / 425 W column 2, Imp rowSTCScope exact_model_columnSource unit ARevision TSM_NA_EN_2026_AChecked 2026-10-02 | 9.96 A
EvidenceSource ↗
PDF page 2, Electrical Data (STC), exact TSM-430NEG9R.25 / 430 W column 1, Imp rowSTCScope exact_model_columnSource unit ARevision TSM_EN_2025_BChecked 2026-10-02 |
Module efficiencyⓘExact STC power column, not bifacial rear-side gain. | 21.3 %
EvidenceSource ↗
PDF page 2, Electrical Data (STC), exact TSM-425NEG9RH.25 / 425 W column 2, Module efficiency rowSTCScope exact_model_columnSource unit %Revision TSM_NA_EN_2026_AChecked 2026-10-02 | 21.5 %
EvidenceSource ↗
PDF page 2, Electrical Data (STC), exact TSM-430NEG9R.25 / 430 W column 1, Module efficiency rowSTCScope exact_model_columnSource unit %Revision TSM_EN_2025_BChecked 2026-10-02 |
| Physical specifications | ||
LengthⓘNominal manufacturer dimension. | 1762 mm
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family length rowManufacturer nominal family ratingScope familySource unit mmRevision TSM_NA_EN_2026_AChecked 2026-10-02 | 1762 mm
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family length rowManufacturer nominal family ratingScope familySource unit mmRevision TSM_EN_2025_BChecked 2026-10-02 |
WidthⓘNominal manufacturer dimension. | 1134 mm
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family width rowManufacturer nominal family ratingScope familySource unit mmRevision TSM_NA_EN_2026_AChecked 2026-10-02 | 1134 mm
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family width rowManufacturer nominal family ratingScope familySource unit mmRevision TSM_EN_2025_BChecked 2026-10-02 |
ThicknessⓘUnknown thickness is never inferred from a nearby model. | 35 mm
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family thickness rowManufacturer nominal family ratingScope familySource unit mmRevision TSM_NA_EN_2026_AChecked 2026-10-02 | 30 mm
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family thickness rowManufacturer nominal family ratingScope familySource unit mmRevision TSM_EN_2025_BChecked 2026-10-02 |
Cell technologyⓘShown only when this field has passed integration review. | N-type TOPCon monocrystalline
EvidenceSource ↗
PDF page 1, product identity / technology statementManufacturer-stated cell/module technologyScope familyRevision TSM_NA_EN_2026_AChecked 2026-10-02 | N-type i-TOPCon monocrystalline
EvidenceSource ↗
PDF page 1, product identity / technology statementManufacturer-stated cell/module technologyScope familyRevision TSM_EN_2025_BChecked 2026-10-02 |
Module typeⓘBifacial modules can receive light on both faces; this is not a yield prediction. | Not verified | monofacial
EvidenceSource ↗
PDF page 1 and/or official regional product description, face/construction statementManufacturer-stated or explicitly described module constructionScope familyRevision TSM_EN_2025_BChecked 2026-10-02 |
WeightⓘNominal weight for this documented construction. | 22 kg
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family weight rowManufacturer nominal family ratingScope familySource unit kgRevision TSM_NA_EN_2026_AChecked 2026-10-02 | 21 kg
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family weight rowManufacturer nominal family ratingScope familySource unit kgRevision TSM_EN_2025_BChecked 2026-10-02 |
| Temperature & warranty | ||
Power temperature coefficientⓘChange in rated power per degree; sign and test basis matter. | -0.29 %/°C
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family temperature rowManufacturer family Pmax temperature coefficient, STC referenceScope familySource unit %/°CRevision TSM_NA_EN_2026_AChecked 2026-10-02 | -0.29 %/°C
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family temperature rowManufacturer family Pmax temperature coefficient, STC referenceScope familySource unit %/°CRevision TSM_EN_2025_BChecked 2026-10-02 |
Voltage temperature coefficientⓘRequired for temperature-corrected voltage calculations. | -0.24 %/°C
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family temperature_voc rowManufacturer family Voc temperature coefficient, STC referenceScope familySource unit %/°CRevision TSM_NA_EN_2026_AChecked 2026-10-02 | -0.24 %/°C
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family temperature_voc rowManufacturer family Voc temperature coefficient, STC referenceScope familySource unit %/°CRevision TSM_EN_2025_BChecked 2026-10-02 |
Current temperature coefficientⓘManufacturer coefficient under its stated test conditions. | 0.04 %/°C
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family temperature_isc rowManufacturer family Isc temperature coefficient, STC referenceScope familySource unit %/°CRevision TSM_NA_EN_2026_AChecked 2026-10-02 | 0.04 %/°C
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family temperature_isc rowManufacturer family Isc temperature coefficient, STC referenceScope familySource unit %/°CRevision TSM_EN_2025_BChecked 2026-10-02 |
Nominal module operating temperatureⓘNMOT is distinct from STC cell temperature. | Not verified | Not verified |
Nominal operating cell temperatureⓘNOCT is not substituted for NMOT. | 43 °C
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family noct rowNOCT, manufacturer value; ±2°C tolerance where statedScope familySource unit °CRevision TSM_NA_EN_2026_AChecked 2026-10-02 | 43 °C
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family noct rowNOCT, manufacturer value; ±2°C tolerance where statedScope familySource unit °CRevision TSM_EN_2025_BChecked 2026-10-02 |
Maximum system voltageⓘA module rating, not approval of a proposed string. | 1500 V
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family max_system_voltage rowManufacturer nominal family ratingScope familySource unit VRevision TSM_NA_EN_2026_AChecked 2026-10-02 | 1500 V
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family max_system_voltage rowManufacturer nominal family ratingScope familySource unit VRevision TSM_EN_2025_BChecked 2026-10-02 |
Maximum series fuse ratingⓘInstallation protection still requires a separate design review. | 30 A
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family series_fuse rowManufacturer nominal family ratingScope familySource unit ARevision TSM_NA_EN_2026_AChecked 2026-10-02 | 25 A
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family series_fuse rowManufacturer nominal family ratingScope familySource unit ARevision TSM_EN_2025_BChecked 2026-10-02 |
Power bifacialityⓘRear/front power ratio under the documented condition, not a production uplift. | Not verified | Not verified |
Minimum operating temperatureⓘManufacturer operating range; not ambient design temperature. | -40 °C
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family operating_min rowManufacturer nominal family ratingScope familySource unit °CRevision TSM_NA_EN_2026_AChecked 2026-10-02 | -40 °C
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, shared family operating_min rowManufacturer nominal family ratingScope familySource unit °CRevision TSM_EN_2025_BChecked 2026-10-02 |
Maximum operating temperatureⓘObserve the stated qualifications, including short-term limits. | 85 °C
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, operating temperature range; nominal upper boundManufacturer nominal family ratingScope familySource unit °CRevision TSM_NA_EN_2026_AChecked 2026-10-02 | 70 °C
EvidenceSource ↗
PDF page 2, Temperature ratings / mechanical / maximum ratings, operating temperature range; nominal upper boundManufacturer nominal family ratingScope familySource unit °CRevision TSM_EN_2025_BChecked 2026-10-02 |
Warranty termsⓘEligibility and market-specific conditions must be reviewed. | 25-year product workmanship warranty; 30-year power warranty; 1% first-year degradation, 0.40% annual degradation thereafter.
EvidenceSource ↗
PDF page 1, warranty statement applicable to the familyManufacturer warranty statement / datasheet warranty summaryScope familyRevision TSM_NA_EN_2026_AChecked 2026-10-02 | 25-year product workmanship warranty; 30-year power warranty; 1% first-year degradation, 0.40% annual degradation thereafter.
EvidenceSource ↗
PDF page 1, warranty statement applicable to the familyManufacturer warranty statement / datasheet warranty summaryScope familyRevision TSM_EN_2025_BChecked 2026-10-02 |
| Identity & evidence | ||
Market scopeⓘDifferent market variants are not assumed interchangeable. | North America | Europe |
Product familyⓘThe family label does not establish equivalence. | Vertex S+ | Vertex S+ |
Datasheet revisionⓘSpecifications can change between document revisions. | TSM_NA_EN_2026_A | TSM_EN_2025_B |
Datasheet dateⓘUnknown when not established in the approved record. | Not verified | Not verified |
Source verification dateⓘDate recorded in the source evidence. | 2026-10-02 | 2026-10-02 |
Last integration checkⓘDate of the independent import review. | 2026-10-02 | 2026-10-02 |
| Official source | Datasheet ↗ Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | Datasheet ↗ Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
Specs can vary by market/revision. These are equipment specifications, not an electrical compatibility verdict. Module voltage is not household voltage. Installation suitability requires a separate professional assessment.