PUBLIC CATALOGUE • 1124 solar panel records. Technical coverage is shown separately.

SIDE BY SIDE, SOURCE BY SOURCE

Small details.
Clear differences.

Compare exact models without a universal winner.
Different market variants are not assumed interchangeable.

Technical specifications incomplete

Deep electrical comparison requires reviewed core fields and consistent STC values for every selected model. Review the reasons below and the exact source documents.

  • REC470AA PURE-RX-DC · North America / US domestic-content variant

    missing reviewed power, voc, vmp, isc, imp, temperature.

Edit selection

Highlighted rows differ in value, unit, test condition or rating scope. “Not verified” is an unknown, never zero. On small screens, scroll the table sideways.

2 exact models, grouped specifications
SpecificationsReview condition and scopeREC GroupREC470AA PURE-RX-DCNorth America / US domestic-content variant470 WRisen EnergyRSM108-11-505BNDGGlobal505 W
Electrical · standard test conditions
Rated power
ⓘ

Laboratory DC nameplate power; this is not an annual energy estimate.

470 W 505 W
Evidence
Source ↗ Page 2, STC table, exact model column 4/6: RSM108-11-505BNDG, row PmaxSTCScope exact_model_columnSource unit WRevision REM108-BNDG-EN-H1-1-2026Checked 2026-10-02
Physical specifications
Length
ⓘ

Nominal manufacturer dimension.

1728 mm 1961 mm
Evidence
Source ↗ Page 2 mechanical data for exact datasheet familyManufacturer nominal ratingScope familySource unit mmRevision REM108-BNDG-EN-H1-1-2026Checked 2026-10-02
Width
ⓘ

Nominal manufacturer dimension.

1205 mm 1134 mm
Evidence
Source ↗ Page 2 mechanical data for exact datasheet familyManufacturer nominal ratingScope familySource unit mmRevision REM108-BNDG-EN-H1-1-2026Checked 2026-10-02
Thickness
ⓘ

Unknown thickness is never inferred from a nearby model.

30 mm 30 mm
Evidence
Source ↗ Page 2 mechanical data for exact datasheet familyManufacturer nominal ratingScope familySource unit mmRevision REM108-BNDG-EN-H1-1-2026Checked 2026-10-02
Cell technology
ⓘ

Shown only when this field has passed integration review.

Not verified n-type TOPCon
Evidence
Source ↗ Page 2 cell type n-type TOPConManufacturer nominal ratingScope familyRevision REM108-BNDG-EN-H1-1-2026Checked 2026-10-02
Module type
ⓘ

Bifacial modules can receive light on both faces; this is not a yield prediction.

Not verified Not verified
Weight
ⓘ

Nominal weight for this documented construction.

Not verified 27 kg
Evidence
Source ↗ Page 2 mechanical data for exact datasheet familyManufacturer nominal ratingScope familySource unit kgRevision REM108-BNDG-EN-H1-1-2026Checked 2026-10-02
Temperature & warranty
Power temperature coefficient
ⓘ

Change in rated power per degree; sign and test basis matter.

Not verified -0.29 %/°C
Evidence
Source ↗ Page 2 temperature coefficients for the exact datasheet familyManufacturer temperature coefficientScope familySource unit %/°CRevision REM108-BNDG-EN-H1-1-2026Checked 2026-10-02
Voltage temperature coefficient
ⓘ

Required for temperature-corrected voltage calculations.

Not verified -0.25 %/°C
Evidence
Source ↗ Page 2 temperature coefficients for the exact datasheet familyManufacturer temperature coefficientScope familySource unit %/°CRevision REM108-BNDG-EN-H1-1-2026Checked 2026-10-02
Current temperature coefficient
ⓘ

Manufacturer coefficient under its stated test conditions.

Not verified 0.046 %/°C
Evidence
Source ↗ Page 2 temperature coefficients for the exact datasheet familyManufacturer temperature coefficientScope familySource unit %/°CRevision REM108-BNDG-EN-H1-1-2026Checked 2026-10-02
Nominal module operating temperature
ⓘ

NMOT is distinct from STC cell temperature.

Not verified 44 °C
Evidence
Source ↗ Page 2: nominal module operating temperature 44°C ±2°CManufacturer nominal ratingScope familySource unit °CRevision REM108-BNDG-EN-H1-1-2026Checked 2026-10-02
Nominal operating cell temperature
ⓘ

NOCT is not substituted for NMOT.

Not verified Not verified
Maximum system voltage
ⓘ

A module rating, not approval of a proposed string.

Not verified Not verified
Maximum series fuse rating
ⓘ

Installation protection still requires a separate design review.

Not verified 35 A
Evidence
Source ↗ Page 2 maximum ratings / operating temperature rangeManufacturer nominal ratingScope familySource unit ARevision REM108-BNDG-EN-H1-1-2026Checked 2026-10-02
Power bifaciality
ⓘ

Rear/front power ratio under the documented condition, not a production uplift.

Not verified 80 %
Evidence
Source ↗ Page 2 STC footnote: bifaciality factor 80±5%Manufacturer nominal ratingScope familySource unit %Revision REM108-BNDG-EN-H1-1-2026Checked 2026-10-02
Minimum operating temperature
ⓘ

Manufacturer operating range; not ambient design temperature.

Not verified -40 °C
Evidence
Source ↗ Page 2 maximum ratings / operating temperature rangeManufacturer nominal ratingScope familySource unit °CRevision REM108-BNDG-EN-H1-1-2026Checked 2026-10-02
Maximum operating temperature
ⓘ

Observe the stated qualifications, including short-term limits.

Not verified 85 °C
Evidence
Source ↗ Page 2 maximum ratings / operating temperature rangeManufacturer nominal ratingScope familySource unit °CRevision REM108-BNDG-EN-H1-1-2026Checked 2026-10-02
Warranty terms
ⓘ

Eligibility and market-specific conditions must be reviewed.

Not verified 15-year product warranty / 30-year linear performance warranty; year 30 87.4%
Evidence
Source ↗ Page 1 warranty graphic/text for exact datasheet familyManufacturer nominal ratingScope familyRevision REM108-BNDG-EN-H1-1-2026Checked 2026-10-02
Identity & evidence
Market scope
ⓘ

Different market variants are not assumed interchangeable.

North America / US domestic-content variant Global
Product family
ⓘ

The family label does not establish equivalence.

REC Alpha Pure-RX TOPCon 108
Datasheet revision
ⓘ

Specifications can change between document revisions.

V7 REM108-BNDG-EN-H1-1-2026
Datasheet date
ⓘ

Unknown when not established in the approved record.

2026-06 Not verified
Source verification date
ⓘ

Date recorded in the source evidence.

2026-10-01 2026-10-02
Last integration check
ⓘ

Date of the independent import review.

2026-10-01 2026-10-02
Official sourceDatasheet ↗

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Datasheet ↗

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Specs can vary by market/revision. These are equipment specifications, not an electrical compatibility verdict. Module voltage is not household voltage. Installation suitability requires a separate professional assessment.