PUBLIC CATALOGUE • 1124 solar panel records. Technical coverage is shown separately.

SIDE BY SIDE, SOURCE BY SOURCE

Small details.
Clear differences.

Compare exact models without a universal winner.
Different market variants are not assumed interchangeable.

Edit selection

Highlighted rows differ in value, unit, test condition or rating scope. “Not verified” is an unknown, never zero. On small screens, scroll the table sideways.

2 exact models, grouped specifications
SpecificationsReview condition and scopeAIKOAIKO-A455-MAH54DwPakistan455 WRisen EnergyRSM96-11-440BNDGJapan440 W
Electrical · standard test conditions
Rated power
ⓘ

Laboratory DC nameplate power; this is not an annual energy estimate.

455 W
Evidence
Source ↗ PDF page 2, STC 455 W column 1, power rowSTCScope exact_model_columnSource unit WRevision V4.1_202510_DsDr_ENChecked 2026-10-02
440 W
Evidence
Source ↗ Page 2, STC table, exact model column 1/5: RSM96-11-440BNDG, row PmaxSTCScope exact_model_columnSource unit WRevision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Open-circuit voltage
ⓘ

Module voltage without a load. It is not household voltage.

41 V
Evidence
Source ↗ PDF page 2, STC 455 W column 1, voc rowSTCScope exact_model_columnSource unit VRevision V4.1_202510_DsDr_ENChecked 2026-10-02
34.98 V
Evidence
Source ↗ Page 2, STC table, exact model column 1/5: RSM96-11-440BNDG, row VocSTCScope exact_model_columnSource unit VRevision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Voltage at maximum power
ⓘ

Module operating voltage at STC.

34.56 V
Evidence
Source ↗ PDF page 2, STC 455 W column 1, vmp rowSTCScope exact_model_columnSource unit VRevision V4.1_202510_DsDr_ENChecked 2026-10-02
29.5 V
Evidence
Source ↗ Page 2, STC table, exact model column 1/5: RSM96-11-440BNDG, row VmppSTCScope exact_model_columnSource unit VRevision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Short-circuit current
ⓘ

Module current under the stated test condition.

14.22 A
Evidence
Source ↗ PDF page 2, STC 455 W column 1, isc rowSTCScope exact_model_columnSource unit ARevision V4.1_202510_DsDr_ENChecked 2026-10-02
15.98 A
Evidence
Source ↗ Page 2, STC table, exact model column 1/5: RSM96-11-440BNDG, row IscSTCScope exact_model_columnSource unit ARevision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Current at maximum power
ⓘ

Module operating current at STC.

13.17 A
Evidence
Source ↗ PDF page 2, STC 455 W column 1, imp rowSTCScope exact_model_columnSource unit ARevision V4.1_202510_DsDr_ENChecked 2026-10-02
14.92 A
Evidence
Source ↗ Page 2, STC table, exact model column 1/5: RSM96-11-440BNDG, row ImppSTCScope exact_model_columnSource unit ARevision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Module efficiency
ⓘ

Exact STC power column, not bifacial rear-side gain.

22.8 %
Evidence
Source ↗ PDF page 2, STC 455 W column 1, efficiency rowSTCScope exact_model_columnSource unit %Revision V4.1_202510_DsDr_ENChecked 2026-10-02
22 %
Evidence
Source ↗ Page 2, STC table, exact model column 1/5: RSM96-11-440BNDG, row Module efficiencySTCScope exact_model_columnSource unit %Revision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Physical specifications
Length
ⓘ

Nominal manufacturer dimension.

1757 mm
Evidence
Source ↗ PDF page 2, family length rowManufacturer nominal family ratingScope familySource unit mmRevision V4.1_202510_DsDr_ENChecked 2026-10-02
1762 mm
Evidence
Source ↗ Page 2 mechanical data for exact datasheet familyManufacturer nominal ratingScope familySource unit mmRevision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Width
ⓘ

Nominal manufacturer dimension.

1134 mm
Evidence
Source ↗ PDF page 2, family width rowManufacturer nominal family ratingScope familySource unit mmRevision V4.1_202510_DsDr_ENChecked 2026-10-02
1134 mm
Evidence
Source ↗ Page 2 mechanical data for exact datasheet familyManufacturer nominal ratingScope familySource unit mmRevision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Thickness
ⓘ

Unknown thickness is never inferred from a nearby model.

30 mm
Evidence
Source ↗ PDF page 2, family thickness rowManufacturer nominal family ratingScope familySource unit mmRevision V4.1_202510_DsDr_ENChecked 2026-10-02
30 mm
Evidence
Source ↗ Page 2 mechanical data for exact datasheet familyManufacturer nominal ratingScope familySource unit mmRevision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Cell technology
ⓘ

Shown only when this field has passed integration review.

N-type ABC
Evidence
Source ↗ PDF page 2, family technology rowManufacturer nominal family ratingScope familyRevision V4.1_202510_DsDr_ENChecked 2026-10-02
n-type TOPCon
Evidence
Source ↗ Page 2 cell type n-type TOPConManufacturer nominal ratingScope familyRevision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Module type
ⓘ

Bifacial modules can receive light on both faces; this is not a yield prediction.

Not verified Not verified
Weight
ⓘ

Nominal weight for this documented construction.

24.2 kg
Evidence
Source ↗ PDF page 2, family weight rowNominal mass; ±3%Scope familySource unit kgRevision V4.1_202510_DsDr_ENChecked 2026-10-02
21.5 kg
Evidence
Source ↗ Page 2 mechanical data for exact datasheet familyManufacturer nominal ratingScope familySource unit kgRevision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Temperature & warranty
Power temperature coefficient
ⓘ

Change in rated power per degree; sign and test basis matter.

-0.26 %/°C
Evidence
Source ↗ PDF page 2, family temperature rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision V4.1_202510_DsDr_ENChecked 2026-10-02
-0.29 %/°C
Evidence
Source ↗ Page 2 temperature coefficients for the exact datasheet familyManufacturer temperature coefficientScope familySource unit %/°CRevision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Voltage temperature coefficient
ⓘ

Required for temperature-corrected voltage calculations.

-0.22 %/°C
Evidence
Source ↗ PDF page 2, family temperature_voc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision V4.1_202510_DsDr_ENChecked 2026-10-02
-0.25 %/°C
Evidence
Source ↗ Page 2 temperature coefficients for the exact datasheet familyManufacturer temperature coefficientScope familySource unit %/°CRevision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Current temperature coefficient
ⓘ

Manufacturer coefficient under its stated test conditions.

0.05 %/°C
Evidence
Source ↗ PDF page 2, family temperature_isc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision V4.1_202510_DsDr_ENChecked 2026-10-02
0.046 %/°C
Evidence
Source ↗ Page 2 temperature coefficients for the exact datasheet familyManufacturer temperature coefficientScope familySource unit %/°CRevision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Nominal module operating temperature
ⓘ

NMOT is distinct from STC cell temperature.

Not verified 44 °C
Evidence
Source ↗ Page 2: nominal module operating temperature 44°C ±2°CManufacturer nominal ratingScope familySource unit °CRevision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Nominal operating cell temperature
ⓘ

NOCT is not substituted for NMOT.

Not verified Not verified
Maximum system voltage
ⓘ

A module rating, not approval of a proposed string.

1500 V
Evidence
Source ↗ PDF page 2, family max_system_voltage rowManufacturer nominal family ratingScope familySource unit VRevision V4.1_202510_DsDr_ENChecked 2026-10-02
Not verified
Maximum series fuse rating
ⓘ

Installation protection still requires a separate design review.

25 A
Evidence
Source ↗ PDF page 2, family series_fuse rowManufacturer nominal family ratingScope familySource unit ARevision V4.1_202510_DsDr_ENChecked 2026-10-02
35 A
Evidence
Source ↗ Page 2 maximum ratings / operating temperature rangeManufacturer nominal ratingScope familySource unit ARevision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Power bifaciality
ⓘ

Rear/front power ratio under the documented condition, not a production uplift.

Not verified 80 %
Evidence
Source ↗ Page 2 STC footnote: bifaciality factor 80±5%Manufacturer nominal ratingScope familySource unit %Revision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Minimum operating temperature
ⓘ

Manufacturer operating range; not ambient design temperature.

-40 °C
Evidence
Source ↗ PDF page 2, family operating_min rowManufacturer nominal family ratingScope familySource unit °CRevision V4.1_202510_DsDr_ENChecked 2026-10-02
-40 °C
Evidence
Source ↗ Page 2 maximum ratings / operating temperature rangeManufacturer nominal ratingScope familySource unit °CRevision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Maximum operating temperature
ⓘ

Observe the stated qualifications, including short-term limits.

85 °C
Evidence
Source ↗ PDF page 2, family operating_max rowManufacturer nominal family ratingScope familySource unit °CRevision V4.1_202510_DsDr_ENChecked 2026-10-02
85 °C
Evidence
Source ↗ Page 2 maximum ratings / operating temperature rangeManufacturer nominal ratingScope familySource unit °CRevision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Warranty terms
ⓘ

Eligibility and market-specific conditions must be reviewed.

30-year linear power warranty; product warranty and detailed eligibility require the applicable manufacturer warranty statement.
Evidence
Source ↗ PDF page 1, warranty statement and conditionsManufacturer nominal family ratingScope familyRevision V4.1_202510_DsDr_ENChecked 2026-10-02
15-year product warranty / 30-year linear performance warranty; year 30 87.4%
Evidence
Source ↗ Page 1 warranty graphic/text for exact datasheet familyManufacturer nominal ratingScope familyRevision REM108-BNDG-JAP-H1-2-2025Checked 2026-10-02
Identity & evidence
Market scope
ⓘ

Different market variants are not assumed interchangeable.

Pakistan Japan
Product family
ⓘ

The family label does not establish equivalence.

NEOSTAR 2P+54 Dual-Glass TOPCon 96
Datasheet revision
ⓘ

Specifications can change between document revisions.

V4.1_202510_DsDr_EN REM108-BNDG-JAP-H1-2-2025
Datasheet date
ⓘ

Unknown when not established in the approved record.

2025-10 Not verified
Source verification date
ⓘ

Date recorded in the source evidence.

2026-10-01 2026-10-02
Last integration check
ⓘ

Date of the independent import review.

2026-10-01 2026-10-02
Official sourceDatasheet ↗

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Datasheet ↗

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Specs can vary by market/revision. These are equipment specifications, not an electrical compatibility verdict. Module voltage is not household voltage. Installation suitability requires a separate professional assessment.