SIDE BY SIDE, SOURCE BY SOURCE
Small details.
Clear differences.
Compare exact models without a universal winner.
Different market variants are not assumed interchangeable.
Highlighted rows differ in value, unit, test condition or rating scope. “Not verified” is an unknown, never zero. On small screens, scroll the table sideways.
| SpecificationsReview condition and scope | AIKOAIKO-A615-MAH72MwAustralia615 W | Canadian Solar / CSI SolarCS6.2-66TB-630HNorth America630 W |
|---|---|---|
| Electrical · standard test conditions | ||
Rated powerⓘLaboratory DC nameplate power; this is not an annual energy estimate. | 615 W
EvidenceSource ↗
PDF page 2, STC 615 W column 3, power rowSTCScope exact_model_columnSource unit WRevision V2.1_202501_DsDr_ENChecked 2026-10-02 | 630 W
EvidenceSource ↗
PDF page 2, STC table, exact CS6.2-66TB-630H row, power column 2 (model identifier is column 1)STCScope exact_model_columnSource unit WRevision V1.1_F68_L4A_TXChecked 2026-10-02 |
Open-circuit voltageⓘModule voltage without a load. It is not household voltage. | 54.29 V
EvidenceSource ↗
PDF page 2, STC 615 W column 3, voc rowSTCScope exact_model_columnSource unit VRevision V2.1_202501_DsDr_ENChecked 2026-10-02 | 48.8 V
EvidenceSource ↗
PDF page 2, STC table, exact CS6.2-66TB-630H row, voc column 5 (model identifier is column 1)STCScope exact_model_columnSource unit VRevision V1.1_F68_L4A_TXChecked 2026-10-02 |
Voltage at maximum powerⓘModule operating voltage at STC. | 44.98 V
EvidenceSource ↗
PDF page 2, STC 615 W column 3, vmp rowSTCScope exact_model_columnSource unit VRevision V2.1_202501_DsDr_ENChecked 2026-10-02 | 41.6 V
EvidenceSource ↗
PDF page 2, STC table, exact CS6.2-66TB-630H row, vmp column 3 (model identifier is column 1)STCScope exact_model_columnSource unit VRevision V1.1_F68_L4A_TXChecked 2026-10-02 |
Short-circuit currentⓘModule current under the stated test condition. | 14.44 A
EvidenceSource ↗
PDF page 2, STC 615 W column 3, isc rowSTCScope exact_model_columnSource unit ARevision V2.1_202501_DsDr_ENChecked 2026-10-02 | 16.2 A
EvidenceSource ↗
PDF page 2, STC table, exact CS6.2-66TB-630H row, isc column 6 (model identifier is column 1)STCScope exact_model_columnSource unit ARevision V1.1_F68_L4A_TXChecked 2026-10-02 |
Current at maximum powerⓘModule operating current at STC. | 13.68 A
EvidenceSource ↗
PDF page 2, STC 615 W column 3, imp rowSTCScope exact_model_columnSource unit ARevision V2.1_202501_DsDr_ENChecked 2026-10-02 | 15.16 A
EvidenceSource ↗
PDF page 2, STC table, exact CS6.2-66TB-630H row, imp column 4 (model identifier is column 1)STCScope exact_model_columnSource unit ARevision V1.1_F68_L4A_TXChecked 2026-10-02 |
Module efficiencyⓘExact STC power column, not bifacial rear-side gain. | 23.3 %
EvidenceSource ↗
PDF page 2, STC 615 W column 3, efficiency rowSTCScope exact_model_columnSource unit %Revision V2.1_202501_DsDr_ENChecked 2026-10-02 | 23.3 %
EvidenceSource ↗
PDF page 2, STC table, exact CS6.2-66TB-630H row, efficiency column 7 (model identifier is column 1)STCScope exact_model_columnSource unit %Revision V1.1_F68_L4A_TXChecked 2026-10-02 |
| Physical specifications | ||
LengthⓘNominal manufacturer dimension. | 2323 mm
EvidenceSource ↗
PDF page 2, family length rowManufacturer nominal family ratingScope familySource unit mmRevision V2.1_202501_DsDr_ENChecked 2026-10-02 | 2382 mm
EvidenceSource ↗
PDF page 2, family length rowManufacturer nominal family ratingScope familySource unit mmRevision V1.1_F68_L4A_TXChecked 2026-10-02 |
WidthⓘNominal manufacturer dimension. | 1134 mm
EvidenceSource ↗
PDF page 2, family width rowManufacturer nominal family ratingScope familySource unit mmRevision V2.1_202501_DsDr_ENChecked 2026-10-02 | 1134 mm
EvidenceSource ↗
PDF page 2, family width rowManufacturer nominal family ratingScope familySource unit mmRevision V1.1_F68_L4A_TXChecked 2026-10-02 |
ThicknessⓘUnknown thickness is never inferred from a nearby model. | 33 mm
EvidenceSource ↗
PDF page 2, family thickness rowManufacturer nominal family ratingScope familySource unit mmRevision V2.1_202501_DsDr_ENChecked 2026-10-02 | 40 mm
EvidenceSource ↗
PDF page 2, family thickness rowManufacturer nominal family ratingScope familySource unit mmRevision V1.1_F68_L4A_TXChecked 2026-10-02 |
Cell technologyⓘShown only when this field has passed integration review. | N-type ABC
EvidenceSource ↗
PDF page 2, family technology rowManufacturer nominal family ratingScope familyRevision V2.1_202501_DsDr_ENChecked 2026-10-02 | Not verified |
Module typeⓘBifacial modules can receive light on both faces; this is not a yield prediction. | Not verified | Not verified |
WeightⓘNominal weight for this documented construction. | 27.7 kg
EvidenceSource ↗
PDF page 2, family weight rowNominal massScope familySource unit kgRevision V2.1_202501_DsDr_ENChecked 2026-10-02 | 33.4 kg
EvidenceSource ↗
PDF page 2, family weight rowManufacturer nominal family ratingScope familySource unit kgRevision V1.1_F68_L4A_TXChecked 2026-10-02 |
| Temperature & warranty | ||
Power temperature coefficientⓘChange in rated power per degree; sign and test basis matter. | -0.26 %/°C
EvidenceSource ↗
PDF page 2, family temperature rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision V2.1_202501_DsDr_ENChecked 2026-10-02 | -0.29 %/°C
EvidenceSource ↗
PDF page 2, family temperature rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision V1.1_F68_L4A_TXChecked 2026-10-02 |
Voltage temperature coefficientⓘRequired for temperature-corrected voltage calculations. | -0.22 %/°C
EvidenceSource ↗
PDF page 2, family temperature_voc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision V2.1_202501_DsDr_ENChecked 2026-10-02 | -0.25 %/°C
EvidenceSource ↗
PDF page 2, family temperature_voc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision V1.1_F68_L4A_TXChecked 2026-10-02 |
Current temperature coefficientⓘManufacturer coefficient under its stated test conditions. | 0.05 %/°C
EvidenceSource ↗
PDF page 2, family temperature_isc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision V2.1_202501_DsDr_ENChecked 2026-10-02 | 0.045 %/°C
EvidenceSource ↗
PDF page 2, family temperature_isc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision V1.1_F68_L4A_TXChecked 2026-10-02 |
Nominal module operating temperatureⓘNMOT is distinct from STC cell temperature. | Not verified | 41 °C
EvidenceSource ↗
PDF page 2, family nmot rowNMOT nominal, +/-3 degrees CScope familySource unit °CRevision V1.1_F68_L4A_TXChecked 2026-10-02 |
Nominal operating cell temperatureⓘNOCT is not substituted for NMOT. | Not verified | Not verified |
Maximum system voltageⓘA module rating, not approval of a proposed string. | 1500 V
EvidenceSource ↗
PDF page 2, family max_system_voltage rowManufacturer nominal family ratingScope familySource unit VRevision V2.1_202501_DsDr_ENChecked 2026-10-02 | 1500 V
EvidenceSource ↗
PDF page 2, family max_system_voltage rowManufacturer nominal family ratingScope familySource unit VRevision V1.1_F68_L4A_TXChecked 2026-10-02 |
Maximum series fuse ratingⓘInstallation protection still requires a separate design review. | 25 A
EvidenceSource ↗
PDF page 2, family series_fuse rowManufacturer nominal family ratingScope familySource unit ARevision V2.1_202501_DsDr_ENChecked 2026-10-02 | 35 A
EvidenceSource ↗
PDF page 2, family series_fuse rowManufacturer nominal family ratingScope familySource unit ARevision V1.1_F68_L4A_TXChecked 2026-10-02 |
Power bifacialityⓘRear/front power ratio under the documented condition, not a production uplift. | Not verified | Not verified |
Minimum operating temperatureⓘManufacturer operating range; not ambient design temperature. | -40 °C
EvidenceSource ↗
PDF page 2, family operating_min rowManufacturer nominal family ratingScope familySource unit °CRevision V2.1_202501_DsDr_ENChecked 2026-10-02 | -40 °C
EvidenceSource ↗
PDF page 2, family operating_min rowManufacturer nominal family ratingScope familySource unit °CRevision V1.1_F68_L4A_TXChecked 2026-10-02 |
Maximum operating temperatureⓘObserve the stated qualifications, including short-term limits. | 85 °C
EvidenceSource ↗
PDF page 2, family operating_max rowManufacturer nominal family ratingScope familySource unit °CRevision V2.1_202501_DsDr_ENChecked 2026-10-02 | 85 °C
EvidenceSource ↗
PDF page 2, family operating_max rowManufacturer nominal family ratingScope familySource unit °CRevision V1.1_F68_L4A_TXChecked 2026-10-02 |
Warranty termsⓘEligibility and market-specific conditions must be reviewed. | 30-year linear performance warranty; consult applicable manufacturer warranty terms for eligibility.
EvidenceSource ↗
PDF page 1, warranty statement and conditionsManufacturer nominal family ratingScope familyRevision V2.1_202501_DsDr_ENChecked 2026-10-02 | Not verified |
| Identity & evidence | ||
Market scopeⓘDifferent market variants are not assumed interchangeable. | Australia | North America |
Product familyⓘThe family label does not establish equivalence. | COMET 2N72 Mono-Glass | TOPBiHiKu6 |
Datasheet revisionⓘSpecifications can change between document revisions. | V2.1_202501_DsDr_EN | V1.1_F68_L4A_TX |
Datasheet dateⓘUnknown when not established in the approved record. | 2025-01 | 2026-06 |
Source verification dateⓘDate recorded in the source evidence. | 2026-10-01 | 2026-10-01 |
Last integration checkⓘDate of the independent import review. | 2026-10-01 | 2026-10-01 |
| Official source | Datasheet ↗ Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | Datasheet ↗ Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
Specs can vary by market/revision. These are equipment specifications, not an electrical compatibility verdict. Module voltage is not household voltage. Installation suitability requires a separate professional assessment.