SIDE BY SIDE, SOURCE BY SOURCE
Small details.
Clear differences.
Compare exact models without a universal winner.
Different market variants are not assumed interchangeable.
Highlighted rows differ in value, unit, test condition or rating scope. “Not verified” is an unknown, never zero. On small screens, scroll the table sideways.
| SpecificationsReview condition and scope | JA SolarJAM66D46-715/LBGlobal715 W | JinkoSolarJKM670N-66QL6-BDV-LGlobal670 W |
|---|---|---|
| Electrical · standard test conditions | ||
Rated powerⓘLaboratory DC nameplate power; this is not an annual energy estimate. | 715 W
EvidenceSource ↗
p.2 ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSSTCScope exact_model_columnSource unit WRevision Global-EN-20250709CChecked 2026-10-02 | 670 W
EvidenceSource ↗
PDF page 2, STC 670 W column 6, power rowSTCScope exact_model_columnSource unit WRevision F1-ENChecked 2026-10-02 |
Open-circuit voltageⓘModule voltage without a load. It is not household voltage. | 48.8 V
EvidenceSource ↗
p.2 ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSSTCScope exact_model_columnSource unit VRevision Global-EN-20250709CChecked 2026-10-02 | 50.6 V
EvidenceSource ↗
PDF page 2, STC 670 W column 6, voc rowSTCScope exact_model_columnSource unit VRevision F1-ENChecked 2026-10-02 |
Voltage at maximum powerⓘModule operating voltage at STC. | 41 V
EvidenceSource ↗
p.2 ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSSTCScope exact_model_columnSource unit VRevision Global-EN-20250709CChecked 2026-10-02 | 42.92 V
EvidenceSource ↗
PDF page 2, STC 670 W column 6, vmp rowSTCScope exact_model_columnSource unit VRevision F1-ENChecked 2026-10-02 |
Short-circuit currentⓘModule current under the stated test condition. | 18.55 A
EvidenceSource ↗
p.2 ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSSTCScope exact_model_columnSource unit ARevision Global-EN-20250709CChecked 2026-10-02 | 16.34 A
EvidenceSource ↗
PDF page 2, STC 670 W column 6, isc rowSTCScope exact_model_columnSource unit ARevision F1-ENChecked 2026-10-02 |
Current at maximum powerⓘModule operating current at STC. | 17.44 A
EvidenceSource ↗
p.2 ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSSTCScope exact_model_columnSource unit ARevision Global-EN-20250709CChecked 2026-10-02 | 15.61 A
EvidenceSource ↗
PDF page 2, STC 670 W column 6, imp rowSTCScope exact_model_columnSource unit ARevision F1-ENChecked 2026-10-02 |
Module efficiencyⓘExact STC power column, not bifacial rear-side gain. | 23 %
EvidenceSource ↗
p.2 ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSSTCScope exact_model_columnSource unit %Revision Global-EN-20250709CChecked 2026-10-02 | 24.8 %
EvidenceSource ↗
PDF page 2, STC 670 W column 6, efficiency rowSTCScope exact_model_columnSource unit %Revision F1-ENChecked 2026-10-02 |
| Physical specifications | ||
LengthⓘNominal manufacturer dimension. | 2384 mm
EvidenceSource ↗
p.2 ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit mmRevision Global-EN-20250709CChecked 2026-10-02 | 2382 mm
EvidenceSource ↗
PDF page 2, family length rowManufacturer nominal family ratingScope familySource unit mmRevision F1-ENChecked 2026-10-02 |
WidthⓘNominal manufacturer dimension. | 1303 mm
EvidenceSource ↗
p.2 ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit mmRevision Global-EN-20250709CChecked 2026-10-02 | 1134 mm
EvidenceSource ↗
PDF page 2, family width rowManufacturer nominal family ratingScope familySource unit mmRevision F1-ENChecked 2026-10-02 |
ThicknessⓘUnknown thickness is never inferred from a nearby model. | 33 mm
EvidenceSource ↗
p.2 ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit mmRevision Global-EN-20250709CChecked 2026-10-02 | 30 mm
EvidenceSource ↗
PDF page 2, family thickness rowManufacturer nominal family ratingScope familySource unit mmRevision F1-ENChecked 2026-10-02 |
Cell technologyⓘShown only when this field has passed integration review. | Not verified | Not verified |
Module typeⓘBifacial modules can receive light on both faces; this is not a yield prediction. | Not verified | Not verified |
WeightⓘNominal weight for this documented construction. | 38.2 kg
EvidenceSource ↗
p.2 ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit kgRevision Global-EN-20250709CChecked 2026-10-02 | 32.5 kg
EvidenceSource ↗
PDF page 2, family weight rowManufacturer nominal family ratingScope familySource unit kgRevision F1-ENChecked 2026-10-02 |
| Temperature & warranty | ||
Power temperature coefficientⓘChange in rated power per degree; sign and test basis matter. | -0.29 %/°C
EvidenceSource ↗
p.2 ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit %/°CRevision Global-EN-20250709CChecked 2026-10-02 | -0.26 %/°C
EvidenceSource ↗
PDF page 2, family temperature rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision F1-ENChecked 2026-10-02 |
Voltage temperature coefficientⓘRequired for temperature-corrected voltage calculations. | -0.25 %/°C
EvidenceSource ↗
p.2 ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit %/°CRevision Global-EN-20250709CChecked 2026-10-02 | -0.24 %/°C
EvidenceSource ↗
PDF page 2, family temperature_voc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision F1-ENChecked 2026-10-02 |
Current temperature coefficientⓘManufacturer coefficient under its stated test conditions. | 0.045 %/°C
EvidenceSource ↗
p.2 ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit %/°CRevision Global-EN-20250709CChecked 2026-10-02 | 0.046 %/°C
EvidenceSource ↗
PDF page 2, family temperature_isc rowManufacturer family temperature coefficient, STC referenceScope familySource unit %/°CRevision F1-ENChecked 2026-10-02 |
Nominal module operating temperatureⓘNMOT is distinct from STC cell temperature. | Not verified | Not verified |
Nominal operating cell temperatureⓘNOCT is not substituted for NMOT. | 45 °C
EvidenceSource ↗
p.2 ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit °CRevision Global-EN-20250709CChecked 2026-10-02 | Not verified |
Maximum system voltageⓘA module rating, not approval of a proposed string. | 1500 V
EvidenceSource ↗
p.2 ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit VRevision Global-EN-20250709CChecked 2026-10-02 | 1500 V
EvidenceSource ↗
PDF page 2, family max_system_voltage rowManufacturer nominal family ratingScope familySource unit VRevision F1-ENChecked 2026-10-02 |
Maximum series fuse ratingⓘInstallation protection still requires a separate design review. | 35 A
EvidenceSource ↗
p.2 ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit ARevision Global-EN-20250709CChecked 2026-10-02 | 35 A
EvidenceSource ↗
PDF page 2, family series_fuse rowManufacturer nominal family ratingScope familySource unit ARevision F1-ENChecked 2026-10-02 |
Power bifacialityⓘRear/front power ratio under the documented condition, not a production uplift. | Not verified | 85 %
EvidenceSource ↗
PDF page 2, family bifaciality rowPmax bifaciality, +/-5 percentage pointsScope familySource unit %Revision F1-ENChecked 2026-10-02 |
Minimum operating temperatureⓘManufacturer operating range; not ambient design temperature. | -40 °C
EvidenceSource ↗
p.2 ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit °CRevision Global-EN-20250709CChecked 2026-10-02 | -40 °C
EvidenceSource ↗
PDF page 2, family operating_min rowManufacturer nominal family ratingScope familySource unit °CRevision F1-ENChecked 2026-10-02 |
Maximum operating temperatureⓘObserve the stated qualifications, including short-term limits. | 85 °C
EvidenceSource ↗
p.2 ELECTRICAL PARAMETERS AT STC; MECHANICAL PARAMETERS; OPERATING CONDITIONSmanufacturer_datasheetScope family_shared_valueSource unit °CRevision Global-EN-20250709CChecked 2026-10-02 | 70 °C
EvidenceSource ↗
PDF page 2, family operating_max rowOperating range upper limit; T98 <=70 C; short-term up to85 C, higher operation requires IEC TS 63126 testingScope familySource unit °CRevision F1-ENChecked 2026-10-02 |
Warranty termsⓘEligibility and market-specific conditions must be reviewed. | Not verified | Not verified |
| Identity & evidence | ||
Market scopeⓘDifferent market variants are not assumed interchangeable. | Global | Global |
Product familyⓘThe family label does not establish equivalence. | DeepBlue 4.0 Pro | Tiger Neo 3.0 — Anti-Dust 66QL6-BDV-L |
Datasheet revisionⓘSpecifications can change between document revisions. | Global-EN-20250709C | F1-EN |
Datasheet dateⓘUnknown when not established in the approved record. | 2025-07-09 | Not verified |
Source verification dateⓘDate recorded in the source evidence. | 2026-10-02 | 2026-10-01 |
Last integration checkⓘDate of the independent import review. | 2026-10-02 | 2026-10-01 |
| Official source | Datasheet ↗ Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | Datasheet ↗ Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
Specs can vary by market/revision. These are equipment specifications, not an electrical compatibility verdict. Module voltage is not household voltage. Installation suitability requires a separate professional assessment.