Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
| Specification | X3-HYBRID-15.0-DSolaX Power · PakistanDeep comparison fields reviewed | GW8KL-ETGoodWe Technologies Co., Ltd. · AustraliaDeep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 15000 WRated output power (on-grid); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit W Official source ↗ Product Parameters > X3-HYBRID-15.0-D > AC INPUT & OUTPUT (ON-GRID) Revision not stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 8000 Wnominal/rated active power; exact source raw value '8000' W. Converted exactly to website base unit; W and VA not interchanged. Source unit W Official source ↗ Technical Data > AC nominal/rated output power Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum AC apparent output | 15000 VAMaximum output apparent power (on-grid); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit VA Official source ↗ PDF p.2 table > X3-HYBRID-15.0-D > Max. output apparent power Revision 2025-04-27 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 8800 VAmaximum apparent power; exact source raw value '8800' VA. Converted exactly to website base unit; W and VA not interchanged. Source unit VA Official source ↗ Technical Data > Max. apparent power to utility grid Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Connection phases | 3Pakistan localized official exact product; three-phase unbalanced output and 3-phase AC topology Official source ↗ Localized official page describes X3-HYBRID G4 as three-phase and exact product parameters roster. Field: Three-phase connection / three-phase unbalanced output; exact model X3-HYBRID-15.0-D. Revision Unknown · Checked 2026-10-03 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 3Connection phase count bound to Task10 exact identity (Three phase); nominal wiring/voltage evidence retained. Official source ↗ Technical Data > Nominal output voltage Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| PV input & tracking | ||
| Independent MPPT trackers | 2Number of MPP trackers; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ Product Parameters > X3-HYBRID-15.0-D > No. of MPP trackers / strings per MPPT Revision not stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 2count; exact model/market Task10 evidence reused. Official source ↗ Technical Data > Number of MPPT trackers Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window minimum | 180 VMPPT voltage range (not a full-power MPPT range); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit V Official source ↗ Product Parameters > X3-HYBRID-15.0-D > MPPT voltage range Revision not stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 200 Voperating range; endpoint of exact official range [200, 850], not the absolute DC limit. Source unit V Official source ↗ Technical Data > MPPT operating voltage range Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window maximum | 950 VMPPT voltage range (not a full-power MPPT range); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit V Official source ↗ Product Parameters > X3-HYBRID-15.0-D > MPPT voltage range Revision not stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 850 Voperating range; endpoint of exact official range [200, 850], not the absolute DC limit. Source unit V Official source ↗ Technical Data > MPPT operating voltage range Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| DC operating voltage minimum | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown |
| Maximum PV input voltage | 1000 VMaximum PV input voltage; upper DC voltage limit; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit V Official source ↗ PDF p.2 table > Max. PV input voltage, footnote ① Revision 2025-04-27 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 1000 Vmaximum; exact model/market Task10 evidence reused. Source unit V Official source ↗ Technical Data > PV max. input voltage Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum input current per tracker/input | 28 / 16 AMPPT1/MPPT2 maximum input current; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit A Official source ↗ Product Parameters > X3-HYBRID-15.0-D > Max. input current per MPPT Revision not stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 22 Aper-MPPT maximum; exact per-MPPT sequence [12.5, 22.0]; scalar stores the maximum listed per-MPPT value, not a sum. Source unit A Official source ↗ Technical Data > Max. input current per MPPT Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum PV short-circuit current | 35 / 20 AMPPT1/MPPT2 maximum input short-circuit current; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit A Official source ↗ PDF p.2 table > X3-HYBRID-15.0-D > Max. input short circuit current per MPPT Revision 2025-04-27 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 27.6 Aper-MPPT maximum; exact per-MPPT sequence [15.2, 27.6]; scalar stores the maximum listed per-MPPT value, not a sum. Source unit A Official source ↗ Technical Data > Max. short-circuit current per MPPT Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Efficiency & environment | ||
| Maximum conversion efficiency | 98 %Maximum conversion efficiency; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit % Official source ↗ PDF p.2 table > EFFICIENCY > Max. efficiency Revision 2025-04-27 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 97.6 %maximum efficiency; exact model/market Task10 evidence reused. Source unit % Official source ↗ Technical Data > Max. efficiency Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| European efficiency | 97.7 %European efficiency; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit % Official source ↗ PDF p.2 table > EFFICIENCY > European efficiency Revision 2025-04-27 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 96.8 %European efficiency; exact model/market Task10 evidence reused. Source unit % Official source ↗ Technical Data > European efficiency Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Operating ambient temperature minimum | -35 °COperating ambient temperature range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit °C Official source ↗ PDF p.2 table > ENVIRONMENT LIMIT > Operation temperature range Revision 2025-04-27 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | -35 °Coperating range; lower endpoint of exact official range [-35, 60]. Source unit °C Official source ↗ Technical Data > Operating temperature range Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Operating ambient temperature maximum | 60 °COperating ambient temperature range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit °C Official source ↗ PDF p.2 table > ENVIRONMENT LIMIT > Operation temperature range Revision 2025-04-27 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 60 °Coperating range; upper endpoint of exact official range [-35, 60]. Source unit °C Official source ↗ Technical Data > Operating temperature range Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Enclosure protection | IP65Ingress protection; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ Product Parameters > X3-HYBRID-15.0-D > Ingress protection Revision not stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval. Official source ↗ Official technical data / Ingress Protection Rating; exact family/model applicability for GW8KL-ET. Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Surge protection | Unknown | DC: Type III; AC: Type IIIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ Official Protection table / surge-protection rows for family containing exact model GW8KL-ET. Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Warranty | ||
| Warranty and eligibility | Unknown | Unknown |