PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

Hybrid / smart energy inverter 2 exact records · Differences include rating conditions and scope.
Edit selection
Inverter electrical comparison
SpecificationX3-HYBRID-15.0-DSolaX Power · PakistanDeep comparison fields reviewedGW8KL-ETGoodWe Technologies Co., Ltd. · AustraliaDeep comparison fields reviewed
AC output
Rated AC active power15000 WRated output power (on-grid); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit W
Official source ↗
Product Parameters > X3-HYBRID-15.0-D > AC INPUT & OUTPUT (ON-GRID)
Revision not stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

8000 Wnominal/rated active power; exact source raw value '8000' W. Converted exactly to website base unit; W and VA not interchanged.
Source unit W
Official source ↗
Technical Data > AC nominal/rated output power
Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum AC apparent output15000 VAMaximum output apparent power (on-grid); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit VA
Official source ↗
PDF p.2 table > X3-HYBRID-15.0-D > Max. output apparent power
Revision 2025-04-27 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

8800 VAmaximum apparent power; exact source raw value '8800' VA. Converted exactly to website base unit; W and VA not interchanged.
Source unit VA
Official source ↗
Technical Data > Max. apparent power to utility grid
Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Connection phases3Pakistan localized official exact product; three-phase unbalanced output and 3-phase AC topology
Official source ↗
Localized official page describes X3-HYBRID G4 as three-phase and exact product parameters roster. Field: Three-phase connection / three-phase unbalanced output; exact model X3-HYBRID-15.0-D.
Revision Unknown · Checked 2026-10-03

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

3Connection phase count bound to Task10 exact identity (Three phase); nominal wiring/voltage evidence retained.
Official source ↗
Technical Data > Nominal output voltage
Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

PV input & tracking
Independent MPPT trackers2Number of MPP trackers; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
Product Parameters > X3-HYBRID-15.0-D > No. of MPP trackers / strings per MPPT
Revision not stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

2count; exact model/market Task10 evidence reused.
Official source ↗
Technical Data > Number of MPPT trackers
Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT operating window minimum180 VMPPT voltage range (not a full-power MPPT range); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit V
Official source ↗
Product Parameters > X3-HYBRID-15.0-D > MPPT voltage range
Revision not stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

200 Voperating range; endpoint of exact official range [200, 850], not the absolute DC limit.
Source unit V
Official source ↗
Technical Data > MPPT operating voltage range
Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT operating window maximum950 VMPPT voltage range (not a full-power MPPT range); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit V
Official source ↗
Product Parameters > X3-HYBRID-15.0-D > MPPT voltage range
Revision not stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

850 Voperating range; endpoint of exact official range [200, 850], not the absolute DC limit.
Source unit V
Official source ↗
Technical Data > MPPT operating voltage range
Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

DC operating voltage minimumUnknownUnknown
DC operating voltage maximumUnknownUnknown
Maximum PV input voltage1000 VMaximum PV input voltage; upper DC voltage limit; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit V
Official source ↗
PDF p.2 table > Max. PV input voltage, footnote ①
Revision 2025-04-27 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

1000 Vmaximum; exact model/market Task10 evidence reused.
Source unit V
Official source ↗
Technical Data > PV max. input voltage
Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum input current per tracker/input28 / 16 AMPPT1/MPPT2 maximum input current; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit A
Official source ↗
Product Parameters > X3-HYBRID-15.0-D > Max. input current per MPPT
Revision not stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

22 Aper-MPPT maximum; exact per-MPPT sequence [12.5, 22.0]; scalar stores the maximum listed per-MPPT value, not a sum.
Source unit A
Official source ↗
Technical Data > Max. input current per MPPT
Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum PV short-circuit current35 / 20 AMPPT1/MPPT2 maximum input short-circuit current; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit A
Official source ↗
PDF p.2 table > X3-HYBRID-15.0-D > Max. input short circuit current per MPPT
Revision 2025-04-27 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

27.6 Aper-MPPT maximum; exact per-MPPT sequence [15.2, 27.6]; scalar stores the maximum listed per-MPPT value, not a sum.
Source unit A
Official source ↗
Technical Data > Max. short-circuit current per MPPT
Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Efficiency & environment
Maximum conversion efficiency98 %Maximum conversion efficiency; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit %
Official source ↗
PDF p.2 table > EFFICIENCY > Max. efficiency
Revision 2025-04-27 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

97.6 %maximum efficiency; exact model/market Task10 evidence reused.
Source unit %
Official source ↗
Technical Data > Max. efficiency
Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

European efficiency97.7 %European efficiency; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit %
Official source ↗
PDF p.2 table > EFFICIENCY > European efficiency
Revision 2025-04-27 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

96.8 %European efficiency; exact model/market Task10 evidence reused.
Source unit %
Official source ↗
Technical Data > European efficiency
Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Operating ambient temperature minimum-35 °COperating ambient temperature range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit °C
Official source ↗
PDF p.2 table > ENVIRONMENT LIMIT > Operation temperature range
Revision 2025-04-27 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

-35 °Coperating range; lower endpoint of exact official range [-35, 60].
Source unit °C
Official source ↗
Technical Data > Operating temperature range
Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Operating ambient temperature maximum60 °COperating ambient temperature range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit °C
Official source ↗
PDF p.2 table > ENVIRONMENT LIMIT > Operation temperature range
Revision 2025-04-27 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

60 °Coperating range; upper endpoint of exact official range [-35, 60].
Source unit °C
Official source ↗
Technical Data > Operating temperature range
Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Enclosure protectionIP65Ingress protection; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
Product Parameters > X3-HYBRID-15.0-D > Ingress protection
Revision not stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval.
Official source ↗
Official technical data / Ingress Protection Rating; exact family/model applicability for GW8KL-ET.
Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Surge protectionUnknownDC: Type III; AC: Type IIIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated.
Official source ↗
Official Protection table / surge-protection rows for family containing exact model GW8KL-ET.
Revision GoodWe-Single page-20250417-AU-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Warranty
Warranty and eligibilityUnknownUnknown