Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
| Specification | X3-HYBRID-15.0-DSolaX Power · PakistanDeep comparison fields reviewed | SUN2000-8K-LC0Huawei Digital Power / FusionSolar · Pakistan localized current pageDeep comparison fields reviewed | H1-2.5-E-G2-WLFox ESS · Global / ROW official site — exact hybrid modelDeep comparison fields reviewed |
|---|---|---|---|
| AC output | |||
| Rated AC active power | 15000 WRated output power (on-grid); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit W Official source ↗ Product Parameters > X3-HYBRID-15.0-D > AC INPUT & OUTPUT (ON-GRID) Revision not stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 8000 Wrated on-grid output Source unit W Official source ↗ Technical Specification > Efficiency/Input (PV)/Input (DC Battery)/Output (On Grid)/General Data Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 2500 Wrated active AC output; scope: grid AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit W Official source ↗ technical table Rated Output Power Revision V1.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum AC apparent output | 15000 VAMaximum output apparent power (on-grid); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit VA Official source ↗ PDF p.2 table > X3-HYBRID-15.0-D > Max. output apparent power Revision 2025-04-27 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 8800 VAmaximum apparent power Source unit VA Official source ↗ Technical Specification > Efficiency/Input (PV)/Input (DC Battery)/Output (On Grid)/General Data Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 2750 VAmaximum apparent AC output for stated market/grid variant; scope: grid AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit VA Official source ↗ technical table Max. Output Apparent Power; G98 footnote for 3.7kW Revision V1.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Connection phases | 3Pakistan localized official exact product; three-phase unbalanced output and 3-phase AC topology Official source ↗ Localized official page describes X3-HYBRID G4 as three-phase and exact product parameters roster. Field: Three-phase connection / three-phase unbalanced output; exact model X3-HYBRID-15.0-D. Revision Unknown · Checked 2026-10-03 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | single-phasegrid connection Official source ↗ Technical Specification > Efficiency/Input (PV)/Input (DC Battery)/Output (On Grid)/General Data Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 1Official exact-model/family phase identity: single-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference. Official source ↗ p.2 AC INPUT AND OUTPUT (GRID) — Rated Grid Voltage 220/230/240 V; exact H1 model column Revision V1.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| PV input & tracking | |||
| Independent MPPT trackers | 2Number of MPP trackers; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ Product Parameters > X3-HYBRID-15.0-D > No. of MPP trackers / strings per MPPT Revision not stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 3MPP trackers Official source ↗ Technical Specification > Efficiency/Input (PV)/Input (DC Battery)/Output (On Grid)/General Data Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 2independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ technical table No. of MPP Trackers Revision V1.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window minimum | 180 VMPPT voltage range (not a full-power MPPT range); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit V Official source ↗ Product Parameters > X3-HYBRID-15.0-D > MPPT voltage range Revision not stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 40 VReviewed MPPT/usable MPP operating window minimum Source unit V Official source ↗ Technical Specification > Efficiency/Input (PV)/Input (DC Battery)/Output (On Grid)/General Data Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 80 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit V Official source ↗ technical table MPPT Voltage Range; canonical min bound from source range Revision V1.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window maximum | 950 VMPPT voltage range (not a full-power MPPT range); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit V Official source ↗ Product Parameters > X3-HYBRID-15.0-D > MPPT voltage range Revision not stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 560 VReviewed MPPT/usable MPP operating window maximum Source unit V Official source ↗ Technical Specification > Efficiency/Input (PV)/Input (DC Battery)/Output (On Grid)/General Data Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 550 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit V Official source ↗ technical table MPPT Voltage Range; canonical max bound from source range Revision V1.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| DC operating voltage minimum | Unknown | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown | Unknown |
| Maximum PV input voltage | 1000 VMaximum PV input voltage; upper DC voltage limit; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit V Official source ↗ PDF p.2 table > Max. PV input voltage, footnote ① Revision 2025-04-27 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 600 Vmaximum input voltage Source unit V Official source ↗ Technical Specification > Efficiency/Input (PV)/Input (DC Battery)/Output (On Grid)/General Data Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 600 Vmaximum DC voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit V Official source ↗ technical table Max. DC Voltage Revision V1.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum input current per tracker/input | 28 / 16 AMPPT1/MPPT2 maximum input current; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit A Official source ↗ Product Parameters > X3-HYBRID-15.0-D > Max. input current per MPPT Revision not stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 16 Aper MPPT Source unit A Official source ↗ Technical Specification > Efficiency/Input (PV)/Input (DC Battery)/Output (On Grid)/General Data Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 16 / 16 Amaximum input current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 16/16; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit A Official source ↗ technical table Max. Input Current Revision V1.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum PV short-circuit current | 35 / 20 AMPPT1/MPPT2 maximum input short-circuit current; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit A Official source ↗ PDF p.2 table > X3-HYBRID-15.0-D > Max. input short circuit current per MPPT Revision 2025-04-27 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 20 Amaximum short-circuit current Source unit A Official source ↗ Technical Specification > Efficiency/Input (PV)/Input (DC Battery)/Output (On Grid)/General Data Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 20 / 20 Amaximum short-circuit current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit A Official source ↗ technical table Max. Short-circuit Current Revision V1.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Efficiency & environment | |||
| Maximum conversion efficiency | 98 %Maximum conversion efficiency; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit % Official source ↗ PDF p.2 table > EFFICIENCY > Max. efficiency Revision 2025-04-27 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 98.1 %maximum efficiency Source unit % Official source ↗ Technical Specification > Efficiency/Input (PV)/Input (DC Battery)/Output (On Grid)/General Data Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 97.01 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit % Official source ↗ technical table Max Efficiency Revision V1.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| European efficiency | 97.7 %European efficiency; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit % Official source ↗ PDF p.2 table > EFFICIENCY > European efficiency Revision 2025-04-27 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 97.5 %European weighted efficiency Source unit % Official source ↗ Technical Specification > Efficiency/Input (PV)/Input (DC Battery)/Output (On Grid)/General Data Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 95.26 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit % Official source ↗ technical table Euro Efficiency Revision V1.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Operating ambient temperature minimum | -35 °COperating ambient temperature range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit °C Official source ↗ PDF p.2 table > ENVIRONMENT LIMIT > Operation temperature range Revision 2025-04-27 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | -25 °COperating ambient temperature minimum Source unit °C Official source ↗ Technical Specification > Efficiency/Input (PV)/Input (DC Battery)/Output (On Grid)/General Data Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | -25 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit °C Official source ↗ technical table Operating Temperature Range; canonical min bound from source range Revision V1.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Operating ambient temperature maximum | 60 °COperating ambient temperature range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Source unit °C Official source ↗ PDF p.2 table > ENVIRONMENT LIMIT > Operation temperature range Revision 2025-04-27 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 60 °COperating ambient temperature maximum Source unit °C Official source ↗ Technical Specification > Efficiency/Input (PV)/Input (DC Battery)/Output (On Grid)/General Data Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 60 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit °C Official source ↗ technical table Operating Temperature Range; canonical max bound from source range Revision V1.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Enclosure protection | IP65Ingress protection; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval. Official source ↗ Product Parameters > X3-HYBRID-15.0-D > Ingress protection Revision not stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | IP66degree of protection Official source ↗ Technical Specification > Efficiency/Input (PV)/Input (DC Battery)/Output (On Grid)/General Data Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ technical table Ingress Protection Revision V1.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Surge protection | Unknown | Unknown | DC Type II / AC Type IIIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval. Official source ↗ p.2 PROTECTION — SPD row (DC Type II / AC Type III) Revision V1.3 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Warranty | |||
| Warranty and eligibility | Unknown | Unknown | Unknown |