PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

Hybrid / smart energy inverter 2 exact records
Edit selection
Inverter electrical comparison
SpecificationX3-HYBRID-15.0-DSolaX Power · PakistanDeep comparison fields reviewedSUN2000-8K-LC0Huawei Digital Power / FusionSolar · Pakistan localized current pageDeep comparison fields reviewed
AC output
Rated AC active power15000 WRated output power (on-grid); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
8000 Wrated on-grid output
Official source ↗
Maximum AC apparent output15000 VAMaximum output apparent power (on-grid); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
8800 VAmaximum apparent power
Official source ↗
Connection phases3Pakistan localized official exact product; three-phase unbalanced output and 3-phase AC topology
Official source ↗
single-phasegrid connection
Official source ↗
PV input & tracking
Independent MPPT trackers2Number of MPP trackers; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
3MPP trackers
Official source ↗
MPPT operating window minimum180 VMPPT voltage range (not a full-power MPPT range); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
40 VReviewed MPPT/usable MPP operating window minimum
Official source ↗
MPPT operating window maximum950 VMPPT voltage range (not a full-power MPPT range); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
560 VReviewed MPPT/usable MPP operating window maximum
Official source ↗
DC operating voltage minimumUnknownUnknown
DC operating voltage maximumUnknownUnknown
Maximum PV input voltage1000 VMaximum PV input voltage; upper DC voltage limit; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
600 Vmaximum input voltage
Official source ↗
Maximum input current per tracker/input28 / 16 AMPPT1/MPPT2 maximum input current; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
16 Aper MPPT
Official source ↗
Maximum PV short-circuit current35 / 20 AMPPT1/MPPT2 maximum input short-circuit current; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
20 Amaximum short-circuit current
Official source ↗
Efficiency & environment
Maximum conversion efficiency98 %Maximum conversion efficiency; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
98.1 %maximum efficiency
Official source ↗
European efficiency97.7 %European efficiency; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
97.5 %European weighted efficiency
Official source ↗
Operating ambient temperature minimum-35 °COperating ambient temperature range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
-25 °COperating ambient temperature minimum
Official source ↗
Operating ambient temperature maximum60 °COperating ambient temperature range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
60 °COperating ambient temperature maximum
Official source ↗
Enclosure protectionIP65Ingress protection; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
IP66degree of protection
Official source ↗
Surge protectionUnknownUnknown
Warranty
Warranty and eligibilityUnknownUnknown