PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

Hybrid / smart energy inverter 3 exact records · Differences include rating conditions and scope.
Edit selection
Inverter electrical comparison
SpecificationX3-HYBRID-15.0-DSolaX Power · PakistanDeep comparison fields reviewedSUN-7.6K-SG06LP1-EU-CM3Ningbo Deye Inverter Technology Co., Ltd. · Global / Europe (EU-labelled)Deep comparison fields reviewedH3-6.0-SmartFox ESS · Global / ROW official siteDeep comparison fields reviewed
AC output
Rated AC active power15000 WRated output power (on-grid); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit W
Official source ↗
Product Parameters > X3-HYBRID-15.0-D > AC INPUT & OUTPUT (ON-GRID)
Revision not stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

7600 Wrated AC input/output active power
Source unit W
Official source ↗
PDF p.2 Technical Data table
Revision 2026-09-11 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

6000 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit W
Official source ↗
technical table Nominal AC Power
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum AC apparent output15000 VAMaximum output apparent power (on-grid); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit VA
Official source ↗
PDF p.2 table > X3-HYBRID-15.0-D > Max. output apparent power
Revision 2025-04-27 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

8360 VAmaximum AC apparent power
Source unit VA
Official source ↗
PDF p.2 Technical Data table
Revision 2026-09-11 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

6600 VAmaximum apparent AC output for stated market; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit VA
Official source ↗
technical table Max. Apparent AC Power; Belgium footnote where applicable
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Connection phases3Pakistan localized official exact product; three-phase unbalanced output and 3-phase AC topology
Official source ↗
Localized official page describes X3-HYBRID G4 as three-phase and exact product parameters roster. Field: Three-phase connection / three-phase unbalanced output; exact model X3-HYBRID-15.0-D.
Revision Unknown · Checked 2026-10-03

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

1Official current product family identifies exact model as single-phase.
Official source ↗
Family header / grid connection form
Revision current official product page · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
p.2 AC OUTPUT — Rated Grid Voltage 400/230 V; 380/220 V, 3L/N/PE; exact model column
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

PV input & tracking
Independent MPPT trackers2Number of MPP trackers; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
Product Parameters > X3-HYBRID-15.0-D > No. of MPP trackers / strings per MPPT
Revision not stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

3MPP trackers
Official source ↗
PDF p.2 Technical Data table
Revision 2026-09-11 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

3independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
technical table No. of MPP Trackers
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT operating window minimum180 VMPPT voltage range (not a full-power MPPT range); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit V
Official source ↗
Product Parameters > X3-HYBRID-15.0-D > MPPT voltage range
Revision not stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

150 VMPPT range
Source unit V
Official source ↗
PDF p.2 Technical Data table
Revision 2026-09-11 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

120 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit V
Official source ↗
technical table MPPT Voltage Range; canonical min bound from source range
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT operating window maximum950 VMPPT voltage range (not a full-power MPPT range); catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit V
Official source ↗
Product Parameters > X3-HYBRID-15.0-D > MPPT voltage range
Revision not stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

425 VMPPT range
Source unit V
Official source ↗
PDF p.2 Technical Data table
Revision 2026-09-11 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

950 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit V
Official source ↗
technical table MPPT Voltage Range; canonical max bound from source range
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

DC operating voltage minimumUnknownUnknownUnknown
DC operating voltage maximumUnknownUnknownUnknown
Maximum PV input voltage1000 VMaximum PV input voltage; upper DC voltage limit; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit V
Official source ↗
PDF p.2 table > Max. PV input voltage, footnote ①
Revision 2025-04-27 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

500 Vmaximum PV input voltage
Source unit V
Official source ↗
PDF p.2 Technical Data table
Revision 2026-09-11 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

1000 Vmaximum DC voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit V
Official source ↗
technical table Max. DC Voltage; note max operating 950V
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum input current per tracker/input28 / 16 AMPPT1/MPPT2 maximum input current; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit A
Official source ↗
Product Parameters > X3-HYBRID-15.0-D > Max. input current per MPPT
Revision not stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

36 / 18 / 18 Aper-MPPT operating current
Source unit A
Official source ↗
PDF p.2 Technical Data table
Revision 2026-09-11 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

20 / 20 / 20 Amaximum current by MPPT; scope: MPPT1/2/3; raw source cell retained: 20/20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit A
Official source ↗
technical table Max. MPPT Current
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum PV short-circuit current35 / 20 AMPPT1/MPPT2 maximum input short-circuit current; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit A
Official source ↗
PDF p.2 table > X3-HYBRID-15.0-D > Max. input short circuit current per MPPT
Revision 2025-04-27 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

54 / 27 / 27 Aper-MPPT short-circuit current
Source unit A
Official source ↗
PDF p.2 Technical Data table
Revision 2026-09-11 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

25 / 25 / 25 Amaximum short-circuit current by MPPT; scope: MPPT1/2/3; raw source cell retained: 25/25/25; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit A
Official source ↗
technical table Max. Short-circuit Current
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Efficiency & environment
Maximum conversion efficiency98 %Maximum conversion efficiency; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit %
Official source ↗
PDF p.2 table > EFFICIENCY > Max. efficiency
Revision 2025-04-27 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

97.6 %maximum efficiency
Source unit %
Official source ↗
PDF p.2 Technical Data table
Revision 2026-09-11 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

97.7 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit %
Official source ↗
technical table Max. Efficiency
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

European efficiency97.7 %European efficiency; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit %
Official source ↗
PDF p.2 table > EFFICIENCY > European efficiency
Revision 2025-04-27 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

96.5 %Euro efficiency
Source unit %
Official source ↗
PDF p.2 Technical Data table
Revision 2026-09-11 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

97.2 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit %
Official source ↗
technical table European Efficiency
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Operating ambient temperature minimum-35 °COperating ambient temperature range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit °C
Official source ↗
PDF p.2 table > ENVIRONMENT LIMIT > Operation temperature range
Revision 2025-04-27 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

-40 °Coperating temperature and derating threshold; derating above 45 °C
Source unit °C
Official source ↗
PDF p.2 Technical Data table
Revision 2026-09-11 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

-25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit °C
Official source ↗
technical table Operating Temperature; canonical min bound from source range
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Operating ambient temperature maximum60 °COperating ambient temperature range; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Source unit °C
Official source ↗
PDF p.2 table > ENVIRONMENT LIMIT > Operation temperature range
Revision 2025-04-27 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

60 °Coperating temperature and derating threshold; derating above 45 °C
Source unit °C
Official source ↗
PDF p.2 Technical Data table
Revision 2026-09-11 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit °C
Official source ↗
technical table Operating Temperature; canonical max bound from source range
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Enclosure protectionIP65Ingress protection; catalogue evidence only — no compatibility, grid, safety, string-sizing or design approval.
Official source ↗
Product Parameters > X3-HYBRID-15.0-D > Ingress protection
Revision not stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

IP65official enclosure ingress-protection rating
Official source ↗
PDF p.2 Technical Data table
Revision 2026-09-11 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
technical table Ingress Protection
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Surge protectionUnknownType II (DC), Type II (AC)Official current product page surge-protection level.
Official source ↗
Technical Specifications > Equipment Protection > Surge Protection Level
Revision current official product page · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
p.2 PROTECTION — DC/AC Surge Protection row
Revision V2.0 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Warranty
Warranty and eligibilityUnknown5standard warranty; source says up to 10 years may vary by installation country
Official source ↗
PDF p.2 Technical Data table
Revision 2026-09-11 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Unknown