PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

Microinverter 2 exact records
Edit selection
Inverter electrical comparison
SpecificationHMT-1800-4T-208-NAHoymiles Power Electronics Inc. · NORTH_AMERICADeep comparison fields reviewedEZ1-LVAPsystems · USA/CanadaDeep comparison fields reviewed
AC output
Rated AC active powerUnknownUnknown
Maximum AC apparent output1728 VAmaximum_continuous_output_power
Official source ↗
900 VAMaximum Continuous Output Power
Official source ↗
Connection phasesthree-phase / Deltacurrent official North America product-family page
Official source ↗
1Task23 QC-approved exact-model/market manufacturer specification.
Official source ↗
PV input & tracking
Independent MPPT trackers2MPPT_count
Official source ↗
2two independent input channels / MPPTs
Official source ↗
MPPT operating window minimum16 VMPPT_operating_range; lower bound
Official source ↗
27 VPeak Power Tracking Voltage
Official source ↗
MPPT operating window maximum60 VMPPT_operating_range; upper bound
Official source ↗
45 VPeak Power Tracking Voltage
Official source ↗
DC operating voltage minimumUnknown26 VOperating Voltage Range
Official source ↗
DC operating voltage maximumUnknown60 VOperating Voltage Range
Official source ↗
Maximum PV input voltage65 Vmaximum_dc_input_voltage
Official source ↗
60 VMaximum Input Voltage
Official source ↗
Maximum input current per tracker/input15 Amaximum_input_current; per PV input
Official source ↗
18 A18A × 2 inputs; normalized per input
Official source ↗
Maximum PV short-circuit current25 Amaximum_input_short_circuit_current; per PV input
Official source ↗
25 A25A per input
Official source ↗
Efficiency & environment
Maximum conversion efficiency96.5 %CEC_peak_efficiency
Official source ↗
96 %Peak Efficiency
Official source ↗
European efficiencyUnknownUnknown
Operating ambient temperature minimum-40 °Cambient temperature range; lower bound
Official source ↗
-40 °COperating Ambient Temperature Range
Official source ↗
Operating ambient temperature maximum65 °Cambient temperature range; upper bound
Official source ↗
65 °COperating Ambient Temperature Range
Official source ↗
Enclosure protectionIP67enclosure rating
Official source ↗
Type 6Enclosure Environmental Rating
Official source ↗
Surge protectionUnknownUnknown
Warranty
Warranty and eligibilityUnknownUnknown