Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
String inverter
2 exact records
Edit selection
| Specification | T4-G3Fox ESS · Global / ROW official siteDeep comparison fields reviewed | GW10K-MS-G40GoodWe Technologies Co., Ltd. · Global / current international catalogDeep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 4000 Wrated active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 10000 Wnominal output power; exact source raw value '10000' W. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ |
| Maximum AC apparent output | 4400 VAmaximum apparent AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 10000 VAmax AC apparent power; exact source raw value '10000' VA. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ |
| Connection phases | 3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference. Official source ↗ | 1Connection phase count bound to Task10 exact identity (single-phase); nominal wiring/voltage evidence retained. Official source ↗ |
| PV input & tracking | ||
| Independent MPPT trackers | 2independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 3MPP tracker count; exact model/market Task10 evidence reused. Official source ↗ |
| MPPT operating window minimum | 140 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 40 VMPPT operating range; endpoint of exact official range [40, 560], not the absolute DC limit. Official source ↗ |
| MPPT operating window maximum | 1000 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 560 VMPPT operating range; endpoint of exact official range [40, 560], not the absolute DC limit. Official source ↗ |
| DC operating voltage minimum | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown |
| Maximum PV input voltage | 1100 Vmaximum DC input voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 600 Vmax input voltage; exact model/market Task10 evidence reused. Official source ↗ |
| Maximum input current per tracker/input | 14 / 14 Amaximum input current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 14/14; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 20 Aper MPPT; per-MPPT/input maximum, not total inverter current. Official source ↗ |
| Maximum PV short-circuit current | 18.2 / 18.2 Amaximum short-circuit current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 18.2/18.2; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 26 Aper MPPT; per-MPPT/input maximum, not total inverter current. Official source ↗ |
| Efficiency & environment | ||
| Maximum conversion efficiency | 98.6 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 97.9 %maximum efficiency; exact model/market Task10 evidence reused. Official source ↗ |
| European efficiency | 97.8 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 97.3 %European efficiency; exact model/market Task10 evidence reused. Official source ↗ |
| Operating ambient temperature minimum | -25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | -25 °Coperating range; lower endpoint of exact official range [-25, 60]. Official source ↗ |
| Operating ambient temperature maximum | 60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 60 °Coperating range; upper endpoint of exact official range [-25, 60]. Official source ↗ |
| Enclosure protection | IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval. Official source ↗ |
| Surge protection | PV Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval. Official source ↗ | DC: Type II; AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ |
| Warranty | ||
| Warranty and eligibility | Unknown | Unknown |