Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
Hybrid / smart energy inverter
2 exact records
Edit selection
| Specification | GW75K-ETR-L-G10GoodWe Technologies Co., Ltd. · Global catalog (exact country/grid certificate not asserted)Deep comparison fields reviewed | MIN 2500TL-XH2Growatt New Energy · Global / ROWDeep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 75000 WOfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ | 2500 Wrated AC output active power Official source ↗ |
| Maximum AC apparent output | 75000 VAOfficial maximum AC apparent output rating for the exact model; W and VA kept separate and model/market footnotes retained. Official source ↗ | 2500 VAmaximum AC apparent power Official source ↗ |
| Connection phases | 3Connection phase count from official family/model description and exact identity (three-phase). Official source ↗ | single_phaseExact model/market phase classification retained from Task10 source-worker review; no cross-model interpolation. Official source ↗ |
| PV input & tracking | ||
| Independent MPPT trackers | 10Official manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ | 2independent MPP trackers Official source ↗ |
| MPPT operating window minimum | 160 VEndpoint of the official MPPT operating voltage range for the exact model; not the absolute DC limit. Official source ↗ | 40 VMPPT operating voltage range Official source ↗ |
| MPPT operating window maximum | 800 VEndpoint of the official MPPT operating voltage range for the exact model; not the absolute DC limit. Official source ↗ | 490 VMPPT operating voltage range Official source ↗ |
| DC operating voltage minimum | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown |
| Maximum PV input voltage | 850 VOfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ | 500 VPV maximum input voltage Official source ↗ |
| Maximum input current per tracker/input | 42 AOfficial maximum per-MPPT value for the exact model; not summed across trackers. Official source ↗ | 16 Amaximum PV current per MPPT Official source ↗ |
| Maximum PV short-circuit current | 55 AOfficial maximum per-MPPT value for the exact model; not summed across trackers. Official source ↗ | 24 Amaximum PV short-circuit current per MPPT Official source ↗ |
| Efficiency & environment | ||
| Maximum conversion efficiency | 97.4 %Official manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ | 98.2 %maximum efficiency Official source ↗ |
| European efficiency | 96.8 %Official manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ | Unknown |
| Operating ambient temperature minimum | -35 °COfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ | -30 °Coperating ambient range Official source ↗ |
| Operating ambient temperature maximum | 60 °COfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ | 60 °Coperating ambient range Official source ↗ |
| Enclosure protection | IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval. Official source ↗ | IP66enclosure ingress protection Official source ↗ |
| Surge protection | DC: Type II (Type I + II optional); AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ | Unknown |
| Warranty | ||
| Warranty and eligibility | Unknown | 10Manufacturer warranty statement/options as published; eligibility and local terms may vary and are not independently granted by this catalogue review. QC schema normalization: canonical display-field unit is ''; original Task18 unit metadata was 'years'. The value semantics are preserved in the field value/test condition. Official source ↗ |