PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

String inverter 3 exact records
Edit selection
Inverter electrical comparison
SpecificationGW75K-GT-LV-G10GoodWe Technologies Co., Ltd. · Global catalog (country/grid exceptions separated as material variants)Deep comparison fields reviewedS1500-G3Fox ESS · Global / ROW official siteDeep comparison fields reviewedR80-G2Fox ESS · Global / ROW official siteDeep comparison fields reviewed
AC output
Rated AC active power75000 WNominal output power; exact source raw value '75 kW' kW. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
1500 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
80000 Wrated active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum AC apparent output75000 VAMax AC apparent power; exact source raw value '75 kVA' kVA. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
1650 VAmaximum apparent AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
88000 VAmaximum apparent AC output for stated market; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Connection phases3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained.
Official source ↗
1Official exact-model/family phase identity: single-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
PV input & tracking
Independent MPPT trackers8MPP trackers; exact model/market Task10 evidence reused.
Official source ↗
1independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
9Integrated independent MPP tracker count; exact R(G2) model grouping
Official source ↗
MPPT operating window minimum180 VMPPT operating range; endpoint of exact official range [180, 800], not the absolute DC limit.
Official source ↗
50 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
200 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
MPPT operating window maximum800 VMPPT operating range; endpoint of exact official range [180, 800], not the absolute DC limit.
Official source ↗
480 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
1000 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
DC operating voltage minimumUnknownUnknownUnknown
DC operating voltage maximumUnknownUnknownUnknown
Maximum PV input voltage800 VMax input voltage; exact model/market Task10 evidence reused.
Official source ↗
500 Vmaximum DC input voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
1100 Vmaximum DC input voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum input current per tracker/input42 AMax input current per MPPT; per-MPPT/input maximum, not total inverter current.
Official source ↗
20 Amaximum input current; scope: input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
40 Amaximum input current at source scope; scope: source table scope; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum PV short-circuit current52.5 AMax short circuit current per MPPT; per-MPPT/input maximum, not total inverter current.
Official source ↗
26 Amaximum short-circuit current; scope: input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
50 Amaximum short-circuit current at source scope; scope: source table scope; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Efficiency & environment
Maximum conversion efficiency98.8 %Max efficiency; exact model/market Task10 evidence reused.
Official source ↗
97.3 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
98.6 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
European efficiency98.3 %European efficiency; exact model/market Task10 evidence reused.
Official source ↗
96.5 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
98.2 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature minimum-30 °COperating temp; lower endpoint of exact official range [-30, 60].
Official source ↗
-25 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
-30 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature maximum60 °COperating temp; upper endpoint of exact official range [-30, 60].
Official source ↗
60 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Enclosure protectionIP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval.
Official source ↗
IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
IP66ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Surge protectionDC: Type II (Type I + II optional where stated); AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated.
Official source ↗
DC Type II / AC Type II (optional)Manufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
Warranty
Warranty and eligibilityUnknownUnknownUnknown