Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
String inverter
2 exact records
Edit selection
| Specification | Verto 20.0Fronius International GmbH · Global/International current Help CenterDeep comparison fields reviewed | GW50KLV-MTGoodWe Technologies Co., Ltd. · South America (GoodWe official positioning; exact country/grid certificate not asserted)Deep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 20000 W Official source ↗ | 50000 WOfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ |
| Maximum AC apparent output | 20000 VA Official source ↗ | 55000 VAOfficial maximum AC apparent output rating for the exact model; W and VA kept separate and model/market footnotes retained. Official source ↗ |
| Connection phases | three-phase Official source ↗ | 3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained. Official source ↗ |
| PV input & tracking | ||
| Independent MPPT trackers | 3 Official source ↗ | 4Official manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ |
| MPPT operating window minimum | 150 VReviewed MPPT/usable MPP operating window minimum Official source ↗ | 200 VEndpoint of the official MPPT operating voltage range for the exact model; not the absolute DC limit. Official source ↗ |
| MPPT operating window maximum | 870 VReviewed MPPT/usable MPP operating window maximum Official source ↗ | 650 VEndpoint of the official MPPT operating voltage range for the exact model; not the absolute DC limit. Official source ↗ |
| DC operating voltage minimum | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown |
| Maximum PV input voltage | 1000 V Official source ↗ | 800 VOfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ |
| Maximum input current per tracker/input | 28 A Official source ↗ | 44 AOfficial maximum per-MPPT value for the exact model; not summed across trackers. Official source ↗ |
| Maximum PV short-circuit current | 50 A Official source ↗ | 55 AOfficial maximum per-MPPT value for the exact model; not summed across trackers. Official source ↗ |
| Efficiency & environment | ||
| Maximum conversion efficiency | 98.56 % Official source ↗ | 98.7 %Official manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ |
| European efficiency | Unknown | 98.3 %Official manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ |
| Operating ambient temperature minimum | -40 °COperating ambient temperature minimum Official source ↗ | -30 °COfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ |
| Operating ambient temperature maximum | 60 °COperating ambient temperature maximum Official source ↗ | 60 °COfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied. Official source ↗ |
| Enclosure protection | IP66 Official source ↗ | IP65Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval. Official source ↗ |
| Surge protection | Unknown | DC: Type II; AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ |
| Warranty | ||
| Warranty and eligibility | Unknown | Unknown |