PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

String inverter 2 exact records
Edit selection
Inverter electrical comparison
SpecificationVerto 20.0Fronius International GmbH · Global/International current Help CenterDeep comparison fields reviewedGW50KLV-MTGoodWe Technologies Co., Ltd. · South America (GoodWe official positioning; exact country/grid certificate not asserted)Deep comparison fields reviewed
AC output
Rated AC active power20000 W
Official source ↗
50000 WOfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied.
Official source ↗
Maximum AC apparent output20000 VA
Official source ↗
55000 VAOfficial maximum AC apparent output rating for the exact model; W and VA kept separate and model/market footnotes retained.
Official source ↗
Connection phasesthree-phase
Official source ↗
3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained.
Official source ↗
PV input & tracking
Independent MPPT trackers3
Official source ↗
4Official manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied.
Official source ↗
MPPT operating window minimum150 VReviewed MPPT/usable MPP operating window minimum
Official source ↗
200 VEndpoint of the official MPPT operating voltage range for the exact model; not the absolute DC limit.
Official source ↗
MPPT operating window maximum870 VReviewed MPPT/usable MPP operating window maximum
Official source ↗
650 VEndpoint of the official MPPT operating voltage range for the exact model; not the absolute DC limit.
Official source ↗
DC operating voltage minimumUnknownUnknown
DC operating voltage maximumUnknownUnknown
Maximum PV input voltage1000 V
Official source ↗
800 VOfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied.
Official source ↗
Maximum input current per tracker/input28 A
Official source ↗
44 AOfficial maximum per-MPPT value for the exact model; not summed across trackers.
Official source ↗
Maximum PV short-circuit current50 A
Official source ↗
55 AOfficial maximum per-MPPT value for the exact model; not summed across trackers.
Official source ↗
Efficiency & environment
Maximum conversion efficiency98.56 %
Official source ↗
98.7 %Official manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied.
Official source ↗
European efficiencyUnknown98.3 %Official manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied.
Official source ↗
Operating ambient temperature minimum-40 °COperating ambient temperature minimum
Official source ↗
-30 °COfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied.
Official source ↗
Operating ambient temperature maximum60 °COperating ambient temperature maximum
Official source ↗
60 °COfficial manufacturer technical-table value for the exact model; no compatibility, grid, design or publication approval implied.
Official source ↗
Enclosure protectionIP66
Official source ↗
IP65Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval.
Official source ↗
Surge protectionUnknownDC: Type II; AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated.
Official source ↗
Warranty
Warranty and eligibilityUnknownUnknown