PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

Hybrid / smart energy inverter 2 exact records
Edit selection
Inverter electrical comparison
SpecificationGW8KL-ETGoodWe Technologies Co., Ltd. · AustraliaDeep comparison fields reviewedKH9Fox ESS · Global / ROW official siteDeep comparison fields reviewed
AC output
Rated AC active power8000 Wnominal/rated active power; exact source raw value '8000' W. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
9000 WAC OUTPUT rated active power; exact KH model
Official source ↗
Maximum AC apparent output8800 VAmaximum apparent power; exact source raw value '8800' VA. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
9900 VAmaximum apparent AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Connection phases3Connection phase count bound to Task10 exact identity (Three phase); nominal wiring/voltage evidence retained.
Official source ↗
1Official exact-model/family phase identity: single-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
PV input & tracking
Independent MPPT trackers2count; exact model/market Task10 evidence reused.
Official source ↗
4independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
MPPT operating window minimum200 Voperating range; endpoint of exact official range [200, 850], not the absolute DC limit.
Official source ↗
80 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
MPPT operating window maximum850 Voperating range; endpoint of exact official range [200, 850], not the absolute DC limit.
Official source ↗
500 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
DC operating voltage minimumUnknownUnknown
DC operating voltage maximumUnknownUnknown
Maximum PV input voltage1000 Vmaximum; exact model/market Task10 evidence reused.
Official source ↗
600 Vmaximum DC voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum input current per tracker/input22 Aper-MPPT maximum; exact per-MPPT sequence [12.5, 22.0]; scalar stores the maximum listed per-MPPT value, not a sum.
Official source ↗
16 / 16 / 16 / 16 Amaximum input current by MPPT; scope: MPPT; raw source cell retained: 16/16/16/16; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum PV short-circuit current27.6 Aper-MPPT maximum; exact per-MPPT sequence [15.2, 27.6]; scalar stores the maximum listed per-MPPT value, not a sum.
Official source ↗
20 / 20 / 20 / 20 Amaximum short-circuit current by MPPT; scope: MPPT; raw source cell retained: 20/20/20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Efficiency & environment
Maximum conversion efficiency97.6 %maximum efficiency; exact model/market Task10 evidence reused.
Official source ↗
97.8 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
European efficiency96.8 %European efficiency; exact model/market Task10 evidence reused.
Official source ↗
97.4 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature minimum-35 °Coperating range; lower endpoint of exact official range [-35, 60].
Official source ↗
-25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature maximum60 °Coperating range; upper endpoint of exact official range [-35, 60].
Official source ↗
60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Enclosure protectionIP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval.
Official source ↗
IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Surge protectionDC: Type III; AC: Type IIIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated.
Official source ↗
DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
Warranty
Warranty and eligibilityUnknownUnknown