PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

Hybrid / smart energy inverter 2 exact records
Edit selection
Inverter electrical comparison
SpecificationSBSE7.7-US-50SMA Solar Technology AG · United StatesDeep comparison fields reviewedGW50K07-ETCGoodWe Technologies Co., Ltd. · Global catalog (Australia/Germany grid-range settings separated as material variants)Deep comparison fields reviewed
AC output
Rated AC active power7680 Wrated AC active power at 240 V, 60 Hz
Official source ↗
50000 WOn-grid nominal output power; exact source raw value '50 kW' kW. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
Maximum AC apparent output7680 VAmaximum apparent AC power
Official source ↗
55000 VAMax apparent power to utility grid; exact source raw value '55 kVA' kVA. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
Connection phases1Official SMA America product page explicitly identifies this exact SBSE-US family as a 1-phase / single-phase hybrid inverter.
Official source ↗
3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained.
Official source ↗
PV input & tracking
Independent MPPT trackers3independent MPPT inputs
Official source ↗
1MPP trackers; exact model/market Task10 evidence reused.
Official source ↗
MPPT operating window minimum180 Vrated MPP voltage range
Official source ↗
250 VMPPT operating range; endpoint of exact official range [250, 960], not the absolute DC limit.
Official source ↗
MPPT operating window maximum480 Vrated MPP voltage range
Official source ↗
960 VMPPT operating range; endpoint of exact official range [250, 960], not the absolute DC limit.
Official source ↗
DC operating voltage minimumUnknownUnknown
DC operating voltage maximumUnknownUnknown
Maximum PV input voltage600 Vmaximum DC voltage
Official source ↗
1000 VPV max input voltage; exact model/market Task10 evidence reused.
Official source ↗
Maximum input current per tracker/input15 Aper MPPT
Official source ↗
100 AMax input current per MPPT; per-MPPT/input maximum, not total inverter current.
Official source ↗
Maximum PV short-circuit current30 Aper MPPT
Official source ↗
125 AMax short circuit current per MPPT; per-MPPT/input maximum, not total inverter current.
Official source ↗
Efficiency & environment
Maximum conversion efficiency98.1 %Current official SMA datasheet max-efficiency row; exact model column/family span visually checked.
Official source ↗
97.6 %Max efficiency; exact model/market Task10 evidence reused.
Official source ↗
European efficiencyUnknown97.3 %European efficiency; exact model/market Task10 evidence reused.
Official source ↗
Operating ambient temperature minimum-25 °Cambient operating range; datasheet states with derating
Official source ↗
-20 °COperating temp; >45°C derating; lower endpoint of exact official range [-20, 60].
Official source ↗
Operating ambient temperature maximum60 °Cambient operating range; datasheet states with derating
Official source ↗
60 °COperating temp; >45°C derating; upper endpoint of exact official range [-20, 60].
Official source ↗
Enclosure protectionIP65electronics ingress protection
Official source ↗
IP20Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval.
Official source ↗
Surge protectionUnknownDC: Type II (Type I + II optional); AC: Type II (Type I + II optional)Official surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated.
Official source ↗
Warranty
Warranty and eligibility10 years standard; extensions stated up to 25 yearsstandard warranty; extension available Maximum extension horizon from same official source.
Official source ↗
Unknown