Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
| Specification | G9-VBFox ESS · Global / ROW — current -VB manual variantDeep comparison fields reviewed | Fronius Symo GEN24 8.0Fronius International GmbH · Europe / ROWDeep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 9000 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit W Official source ↗ manual p.15 Nominal Active AC power Revision V1.0.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 8000 W Source unit W Official source ↗ Technical Data > Output Data > AC nominal output Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum AC apparent output | 9900 VAmaximum apparent AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit VA Official source ↗ manual p.15 Max. apparent AC power Revision V1.0.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 8000 VA Source unit VA Official source ↗ Technical Data > Output Data > Max. output power Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Connection phases | 1Official exact-model/family phase identity: single-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference. Official source ↗ manual title/scope “G Series Single-phase Inverter”; Scope of Validity exact -VB model list Revision V1.0.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | three-phase Official source ↗ Technical Data > Output Data > Grid connection Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| PV input & tracking | ||
| Independent MPPT trackers | 2independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ manual p.14 No. of MPP trackers Revision V1.0.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 2 Official source ↗ Technical Data > Input Data > Number of MPP trackers Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window minimum | 60 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit V Official source ↗ manual p.14 MPPT voltage range; canonical min bound from source range Revision V1.0.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 80 VReviewed MPPT/usable MPP operating window minimum Source unit V Official source ↗ Technical Data > Input Data > Usable MPP voltage range Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window maximum | 550 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit V Official source ↗ manual p.14 MPPT voltage range; canonical max bound from source range Revision V1.0.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 800 VReviewed MPPT/usable MPP operating window maximum Source unit V Official source ↗ Technical Data > Input Data > Usable MPP voltage range Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| DC operating voltage minimum | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown |
| Maximum PV input voltage | 600 Vmaximum DC voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit V Official source ↗ manual p.14 Max. DC voltage Revision V1.0.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 1000 V Source unit V Official source ↗ Technical data > Fronius Symo GEN24 8.0/8.0 Plus > DC input data > Maximum input voltage Revision 4204260315 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum input current per tracker/input | 20 / 32 Amaximum input current; scope: input A/input B; raw source cell retained: 20/32; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit A Official source ↗ manual p.14 Max. input current (A/B) Revision V1.0.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | MPPT1 25 / MPPT2 12.5 A Source unit A Official source ↗ Technical data > Fronius Symo GEN24 8.0/8.0 Plus > DC input data > Maximum input current Revision 4204260315 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum PV short-circuit current | 26 / 42 Amaximum short-circuit current; scope: input A/input B; raw source cell retained: 26/42; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit A Official source ↗ manual p.14 Max. short circuit current (A/B) Revision V1.0.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | MPPT1 40 / MPPT2 20 A Source unit A Official source ↗ Technical data > Fronius Symo GEN24 8.0/8.0 Plus > DC input data > Maximum short circuit current for module array Revision 4204260315 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Efficiency & environment | ||
| Maximum conversion efficiency | 97.8 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit % Official source ↗ manual p.16 Max. efficiency Revision V1.0.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 98.2 % Source unit % Official source ↗ Technical Data > Efficiency > Max. efficiency (PV - grid) Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| European efficiency | 97.4 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit % Official source ↗ manual p.16 Euro-efficiency Revision V1.0.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | Unknown |
| Operating ambient temperature minimum | -25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit °C Official source ↗ manual p.17 Operating temperature range; canonical min bound from source range Revision V1.0.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | -25 °COperating ambient temperature minimum Source unit °C Official source ↗ Technical Data > General Data > Ambient temperature range Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Operating ambient temperature maximum | 60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Source unit °C Official source ↗ manual p.17 Operating temperature range; canonical max bound from source range Revision V1.0.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 60 °COperating ambient temperature maximum Source unit °C Official source ↗ Technical Data > General Data > Ambient temperature range Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Enclosure protection | IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ manual p.17 Ingress Protection Revision V1.0.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | IP66 Official source ↗ Technical Data > General Data > Degree of protection Revision live web page; no published revision stated · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Surge protection | Unknown | Unknown |
| Warranty | ||
| Warranty and eligibility | Unknown | Unknown |