PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

Hybrid / smart energy inverter 2 exact records · Differences include rating conditions and scope.
Edit selection
Inverter electrical comparison
SpecificationGW80K-ET-G10GoodWe Technologies Co., Ltd. · Global catalog (country/grid exceptions separated as material variants)Deep comparison fields reviewedH1-7.6-USFox ESS · United States / North America — split-phase official datasheetDeep comparison fields reviewed
AC output
Rated AC active power80000 WOn-grid nominal output power
Source unit W
Official source ↗
Revision GoodWe-Single page-20260708-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

7600 Wrated active AC output; scope: grid AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit W
Official source ↗
technical table Rated Grid Output Power
Revision V4.2 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum AC apparent output88000 VAMax apparent power to grid
Source unit VA
Official source ↗
Revision GoodWe-Single page-20260708-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

7600 VAmaximum apparent AC output; scope: grid AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit VA
Official source ↗
technical table Max Grid Output Apparent Power
Revision V4.2 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Connection phasesthree-phaseConnection phases stated by exact-family official manufacturer source
Official source ↗
Revision GoodWe-Single page-20260708-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

split-phaseOfficial exact-model/family phase identity: split-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
p.2 North-American technical specifications — split-phase model table / exact H1-US model column
Revision V4.2 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

PV input & tracking
Independent MPPT trackers8MPP trackers
Official source ↗
Revision GoodWe-Single page-20260708-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

2independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
technical table No. of MPPT
Revision V4.2 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT operating window minimum160 VPV MPPT operating range
Source unit V
Official source ↗
Revision GoodWe-Single page-20260708-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

80 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit V
Official source ↗
technical table MPPT Voltage Range; canonical min bound from source range
Revision V4.2 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT operating window maximum950 VPV MPPT operating range
Source unit V
Official source ↗
Revision GoodWe-Single page-20260708-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

550 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit V
Official source ↗
technical table MPPT Voltage Range; canonical max bound from source range
Revision V4.2 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

DC operating voltage minimumUnknownUnknown
DC operating voltage maximumUnknownUnknown
Maximum PV input voltage1000 VPV max input voltage
Source unit V
Official source ↗
Revision GoodWe-Single page-20260708-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

600 Vmaximum DC input voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit V
Official source ↗
technical table Maximum Input Voltage
Revision V4.2 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum input current per tracker/input42 AMax PV input current per MPPT
Source unit A
Official source ↗
Revision GoodWe-Single page-20260708-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

28 / 14 Amaximum input current by MPPT; scope: MPPT; raw source cell retained: 28/14; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit A
Official source ↗
technical table Max. Input Current
Revision V4.2 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum PV short-circuit current55 AMax PV short circuit current per MPPT
Source unit A
Official source ↗
Revision GoodWe-Single page-20260708-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

44 / 22 Amaximum short-circuit current by MPPT; scope: MPPT; raw source cell retained: 44/22; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit A
Official source ↗
technical table Max. Short-circuit Current
Revision V4.2 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Efficiency & environment
Maximum conversion efficiency98.1 %Max efficiency
Source unit %
Official source ↗
Revision GoodWe-Single page-20260708-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

97.6 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit %
Official source ↗
technical table Max Efficiency
Revision V4.2 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

European efficiency97.7 %European efficiency
Source unit %
Official source ↗
Revision GoodWe-Single page-20260708-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Unknown
Operating ambient temperature minimum-35 °COperating temp
Source unit °C
Official source ↗
Revision GoodWe-Single page-20260708-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

-25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit °C
Official source ↗
technical table Operating Temperature; canonical min bound from source range
Revision V4.2 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Operating ambient temperature maximum60 °COperating temp
Source unit °C
Official source ↗
Revision GoodWe-Single page-20260708-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit °C
Official source ↗
technical table Operating Temperature; canonical max bound from source range
Revision V4.2 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Enclosure protectionIP66Ingress Protection Rating
Official source ↗
Revision GoodWe-Single page-20260708-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Type 4XNEMA enclosure rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
technical table Enclosure Rating
Revision V4.2 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Surge protectionDC Type II (Type I + II optional); AC Type IIProtection table; optionality retained
Official source ↗
Revision GoodWe-Single page-20260708-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
p.2 PROTECTION — SPD row (DC Type II / AC Type II)
Revision V4.2 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Warranty
Warranty and eligibilityUnknown12.5manufacturer stated warranty duration; scope: warranty; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Source unit years
Official source ↗
technical table Warranty
Revision V4.2 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00