Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
Hybrid / smart energy inverter
3 exact records
Edit selection
| Specification | H3-15.0-SmartFox ESS · Global / ROW official siteDeep comparison fields reviewed | H3-12.0-SmartFox ESS · Global / ROW official siteDeep comparison fields reviewed | H1-3.0-E-G2-WLFox ESS · Global / ROW official site — exact hybrid modelDeep comparison fields reviewed |
|---|---|---|---|
| AC output | |||
| Rated AC active power | 15000 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 12000 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 3000 Wrated active AC output; scope: grid AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Maximum AC apparent output | 16500 VAmaximum apparent AC output for stated market; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 13200 VAmaximum apparent AC output for stated market; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 3300 VAmaximum apparent AC output for stated market/grid variant; scope: grid AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Connection phases | 3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference. Official source ↗ | 3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference. Official source ↗ | 1Official exact-model/family phase identity: single-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference. Official source ↗ |
| PV input & tracking | |||
| Independent MPPT trackers | 3independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 3independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 2independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| MPPT operating window minimum | 120 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 120 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 80 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| MPPT operating window maximum | 950 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 950 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 550 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| DC operating voltage minimum | Unknown | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown | Unknown |
| Maximum PV input voltage | 1000 Vmaximum DC voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 1000 Vmaximum DC voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 600 Vmaximum DC voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Maximum input current per tracker/input | 20 / 20 / 20 Amaximum current by MPPT; scope: MPPT1/2/3; raw source cell retained: 20/20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 20 / 20 / 20 Amaximum current by MPPT; scope: MPPT1/2/3; raw source cell retained: 20/20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 16 / 16 Amaximum input current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 16/16; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Maximum PV short-circuit current | 25 / 25 / 25 Amaximum short-circuit current by MPPT; scope: MPPT1/2/3; raw source cell retained: 25/25/25; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 25 / 25 / 25 Amaximum short-circuit current by MPPT; scope: MPPT1/2/3; raw source cell retained: 25/25/25; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 20 / 20 Amaximum short-circuit current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Efficiency & environment | |||
| Maximum conversion efficiency | 97.9 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 97.9 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 97.01 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| European efficiency | 97.2 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 97.2 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 95.26 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Operating ambient temperature minimum | -25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | -25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | -25 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Operating ambient temperature maximum | 60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | 60 °Cambient operating range; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Enclosure protection | IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ | IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval. Official source ↗ |
| Surge protection | DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval. Official source ↗ | DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval. Official source ↗ | DC Type II / AC Type IIIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval. Official source ↗ |
| Warranty | |||
| Warranty and eligibility | Unknown | Unknown | Unknown |