PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

Hybrid / smart energy inverter 3 exact records
Edit selection
Inverter electrical comparison
SpecificationH3-15.0-SmartFox ESS · Global / ROW official siteDeep comparison fields reviewedH3-12.0-SmartFox ESS · Global / ROW official siteDeep comparison fields reviewedH3-10.0-SmartFox ESS · Global / ROW — excluding Belgium safety variantDeep comparison fields reviewed
AC output
Rated AC active power15000 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
12000 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
10000 Wnominal active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum AC apparent output16500 VAmaximum apparent AC output for stated market; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
13200 VAmaximum apparent AC output for stated market; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
11000 VAmaximum apparent AC output for stated market; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Connection phases3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
PV input & tracking
Independent MPPT trackers3independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
3independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
3independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
MPPT operating window minimum120 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
120 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
120 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
MPPT operating window maximum950 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
950 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
950 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
DC operating voltage minimumUnknownUnknownUnknown
DC operating voltage maximumUnknownUnknownUnknown
Maximum PV input voltage1000 Vmaximum DC voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
1000 Vmaximum DC voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
1000 Vmaximum DC voltage; scope: PV input; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum input current per tracker/input20 / 20 / 20 Amaximum current by MPPT; scope: MPPT1/2/3; raw source cell retained: 20/20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
20 / 20 / 20 Amaximum current by MPPT; scope: MPPT1/2/3; raw source cell retained: 20/20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
20 / 20 / 20 Amaximum current by MPPT; scope: MPPT1/2/3; raw source cell retained: 20/20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum PV short-circuit current25 / 25 / 25 Amaximum short-circuit current by MPPT; scope: MPPT1/2/3; raw source cell retained: 25/25/25; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
25 / 25 / 25 Amaximum short-circuit current by MPPT; scope: MPPT1/2/3; raw source cell retained: 25/25/25; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
25 / 25 / 25 Amaximum short-circuit current by MPPT; scope: MPPT1/2/3; raw source cell retained: 25/25/25; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Efficiency & environment
Maximum conversion efficiency97.9 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
97.9 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
97.9 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
European efficiency97.2 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
97.2 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
97.2 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature minimum-25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
-25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
-25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature maximum60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Enclosure protectionIP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Surge protectionDC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
Warranty
Warranty and eligibilityUnknownUnknownUnknown