PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

String inverter 2 exact records · Differences include rating conditions and scope.
Edit selection
Inverter electrical comparison
SpecificationFronius Primo GEN24 6.0Fronius International GmbH · Europe / ROW current support selectorDeep comparison fields reviewedVerto 20.0Fronius International GmbH · Global/International current Help CenterDeep comparison fields reviewed
AC output
Rated AC active power6000 WAC nominal output (P_ac,r)
Source unit W
Official source ↗
Technical Data > Output Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

20000 W
Source unit W
Official source ↗
Output Data
Revision live web page; no published revision stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum AC apparent output6000 VAMax. output power (P_ac max); apparent-power unit preserved
Source unit VA
Official source ↗
Technical Data > Output Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

20000 VA
Source unit VA
Official source ↗
Output Data
Revision live web page; no published revision stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Connection phases1Task23 QC-approved exact-model/market manufacturer specification.
Official source ↗
exact model identity; DC voltage/current/MPPT; AC nominal active W; max apparent VA; grid voltage/frequency
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

three-phase
Official source ↗
Technical data > Verto 20.0 > Output data > Grid connection (3~ (N)PE 380/220, 400/230, 440/254, 480/277 V)
Revision 4204260531 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

PV input & tracking
Independent MPPT trackers2Number of MPP trackers
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

3
Official source ↗
Input Data
Revision live web page; no published revision stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT operating window minimum230 VMPP voltage range
Source unit V
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

150 VReviewed MPPT/usable MPP operating window minimum
Source unit V
Official source ↗
Input Data
Revision live web page; no published revision stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT operating window maximum480 VMPP voltage range
Source unit V
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

870 VReviewed MPPT/usable MPP operating window maximum
Source unit V
Official source ↗
Input Data
Revision live web page; no published revision stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

DC operating voltage minimum65 VU_dc min - U_dc max
Source unit V
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Unknown
DC operating voltage maximum600 VU_dc min - U_dc max
Source unit V
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Unknown
Maximum PV input voltage600 VTask23 QC-approved exact-model/market manufacturer specification.
Source unit V
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

1000 V
Source unit V
Official source ↗
Exact-model manual Input data
Revision 4204260531 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum input current per tracker/inputMPPT1 22 / MPPT2 12 AMax. input current (I_dc max), manufacturer two-MPPT topology preserved
Source unit A
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

28 A
Source unit A
Official source ↗
Input Data
Revision live web page; no published revision stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum PV short-circuit currentMPPT1 41.25 / MPPT2 22 AMax. short circuit current, module array; exact two-MPPT scope
Source unit A
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

50 A
Source unit A
Official source ↗
Exact-model manual Input data
Revision 4204260531 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Efficiency & environment
Maximum conversion efficiency97.6 %Max. efficiency (PV-grid)
Source unit %
Official source ↗
Technical Data > Efficiency
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

98.56 %
Source unit %
Official source ↗
Efficiency
Revision live web page; no published revision stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

European efficiencyUnknownUnknown
Operating ambient temperature minimum-40 °CAmbient temperature range; no extra derating curve inferred
Source unit °C
Official source ↗
Technical Data > General Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

-40 °COperating ambient temperature minimum
Source unit °C
Official source ↗
General Data
Revision live web page; no published revision stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Operating ambient temperature maximum60 °CAmbient temperature range; no extra derating curve inferred
Source unit °C
Official source ↗
Technical Data > General Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

60 °COperating ambient temperature maximum
Source unit °C
Official source ↗
General Data
Revision live web page; no published revision stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Enclosure protectionIP66Degree of protection
Official source ↗
Technical Data > General Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

IP66
Official source ↗
General Data
Revision live web page; no published revision stated · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Surge protectionUnknownUnknown
Warranty
Warranty and eligibilityUnknownUnknown