PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

String inverter 3 exact records
Edit selection
Inverter electrical comparison
SpecificationFronius Primo GEN24 6.0Fronius International GmbH · Europe / ROW current support selectorDeep comparison fields reviewedGW5000-MS-30GoodWe Technologies Co., Ltd. · AustraliaDeep comparison fields reviewedR80-G2Fox ESS · Global / ROW official siteDeep comparison fields reviewed
AC output
Rated AC active power6000 WAC nominal output (P_ac,r)
Official source ↗
5000 Wnominal output power; exact source raw value '5000' W. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
80000 Wrated active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum AC apparent output6000 VAMax. output power (P_ac max); apparent-power unit preserved
Official source ↗
5500 VAmax AC apparent power; exact source raw value '5500' VA. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
88000 VAmaximum apparent AC output for stated market; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Connection phases1Task23 QC-approved exact-model/market manufacturer specification.
Official source ↗
1Connection phase count bound to Task10 exact identity (single-phase); nominal wiring/voltage evidence retained.
Official source ↗
3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
PV input & tracking
Independent MPPT trackers2Number of MPP trackers
Official source ↗
3MPP tracker count; exact model/market Task10 evidence reused.
Official source ↗
9Integrated independent MPP tracker count; exact R(G2) model grouping
Official source ↗
MPPT operating window minimum230 VMPP voltage range
Official source ↗
40 VMPPT operating range; endpoint of exact official range [40, 560], not the absolute DC limit.
Official source ↗
200 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
MPPT operating window maximum480 VMPP voltage range
Official source ↗
560 VMPPT operating range; endpoint of exact official range [40, 560], not the absolute DC limit.
Official source ↗
1000 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
DC operating voltage minimum65 VU_dc min - U_dc max
Official source ↗
UnknownUnknown
DC operating voltage maximum600 VU_dc min - U_dc max
Official source ↗
UnknownUnknown
Maximum PV input voltage600 VTask23 QC-approved exact-model/market manufacturer specification.
Official source ↗
600 Vmax input voltage; exact model/market Task10 evidence reused.
Official source ↗
1100 Vmaximum DC input voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum input current per tracker/inputMPPT1 22 / MPPT2 12 AMax. input current (I_dc max), manufacturer two-MPPT topology preserved
Official source ↗
20 Aper MPPT; per-MPPT/input maximum, not total inverter current.
Official source ↗
40 Amaximum input current at source scope; scope: source table scope; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum PV short-circuit currentMPPT1 41.25 / MPPT2 22 AMax. short circuit current, module array; exact two-MPPT scope
Official source ↗
25 Aper MPPT; per-MPPT/input maximum, not total inverter current.
Official source ↗
50 Amaximum short-circuit current at source scope; scope: source table scope; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Efficiency & environment
Maximum conversion efficiency97.6 %Max. efficiency (PV-grid)
Official source ↗
97.8 %maximum efficiency; exact model/market Task10 evidence reused.
Official source ↗
98.6 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
European efficiencyUnknown97.2 %European efficiency; exact model/market Task10 evidence reused.
Official source ↗
98.2 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature minimum-40 °CAmbient temperature range; no extra derating curve inferred
Official source ↗
-25 °Coperating range; lower endpoint of exact official range [-25, 60].
Official source ↗
-30 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature maximum60 °CAmbient temperature range; no extra derating curve inferred
Official source ↗
60 °Coperating range; upper endpoint of exact official range [-25, 60].
Official source ↗
60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Enclosure protectionIP66Degree of protection
Official source ↗
IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval.
Official source ↗
IP66ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Surge protectionUnknownDC SPD and AC SPD shown in official circuit diagram; SPD type/class not stated in reviewed locatorOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated.
Official source ↗
DC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
Warranty
Warranty and eligibilityUnknownUnknownUnknown