String inverter 2 exact records
Edit selection
Inverter electrical comparison
SpecificationFronius Primo GEN24 6.0Fronius International GmbH · Europe / ROW current support selectorDeep comparison fields reviewedT4-MFox ESS · Global / ROW official siteDeep comparison fields reviewed
AC output
Rated AC active power6000 WAC nominal output (P_ac,r)
Official source ↗
4000 Wrated active AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum AC apparent output6000 VAMax. output power (P_ac max); apparent-power unit preserved
Official source ↗
4400 VAmaximum apparent AC output; scope: AC output; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Connection phases1Task23 QC-approved exact-model/market manufacturer specification.
Official source ↗
3Official exact-model/family phase identity: three-phase. For North-American split-phase, the literal split-phase descriptor is retained rather than converted to a false phase count. No grid-approval inference.
Official source ↗
PV input & tracking
Independent MPPT trackers2Number of MPP trackers
Official source ↗
2independent MPP trackers; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
MPPT operating window minimum230 VMPP voltage range
Official source ↗
140 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
MPPT operating window maximum480 VMPP voltage range
Official source ↗
1000 Voperating MPPT range; scope: MPPT; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
DC operating voltage minimum65 VU_dc min - U_dc max
Official source ↗
Unknown
DC operating voltage maximum600 VU_dc min - U_dc max
Official source ↗
Unknown
Maximum PV input voltage600 VTask23 QC-approved exact-model/market manufacturer specification.
Official source ↗
1100 Vmaximum DC input voltage; scope: inverter; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum input current per tracker/inputMPPT1 22 / MPPT2 12 AMax. input current (I_dc max), manufacturer two-MPPT topology preserved
Official source ↗
20 / 20 Amaximum input current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 20/20; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Maximum PV short-circuit currentMPPT1 41.25 / MPPT2 22 AMax. short circuit current, module array; exact two-MPPT scope
Official source ↗
25 / 25 Amaximum short-circuit current by tracker; scope: MPPT1/MPPT2; raw source cell retained: 25/25; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Efficiency & environment
Maximum conversion efficiency97.6 %Max. efficiency (PV-grid)
Official source ↗
98.6 %maximum conversion efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
European efficiencyUnknown97.8 %European efficiency; scope: efficiency; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature minimum-40 °CAmbient temperature range; no extra derating curve inferred
Official source ↗
-25 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Operating ambient temperature maximum60 °CAmbient temperature range; no extra derating curve inferred
Official source ↗
60 °Cambient range and derating threshold; scope: environment; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Enclosure protectionIP66Degree of protection
Official source ↗
IP65ingress protection rating; scope: enclosure; Exact model/market manufacturer evidence; no compatibility, string-sizing, grid or safety approval.
Official source ↗
Surge protectionUnknownDC Type II / AC Type IIManufacturer protection table; optional qualifiers retained where stated. Decorative/catalogue use only; no safety approval.
Official source ↗
Warranty
Warranty and eligibilityUnknownUnknown