Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
String inverter
2 exact records
Edit selection
| Specification | Fronius Primo GEN24 6.0Fronius International GmbH · Europe / ROW current support selectorDeep comparison fields reviewed | GW25K-SDT-30GoodWe Technologies Co., Ltd. · Global catalog (exact country/grid certificate not asserted)Deep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 6000 WAC nominal output (P_ac,r) Official source ↗ | 25000 WNominal output power Official source ↗ |
| Maximum AC apparent output | 6000 VAMax. output power (P_ac max); apparent-power unit preserved Official source ↗ | 25000 VAMax. AC Apparent Power Official source ↗ |
| Connection phases | 1Task23 QC-approved exact-model/market manufacturer specification. Official source ↗ | three-phaseConnection phases stated by exact-family official manufacturer source Official source ↗ |
| PV input & tracking | ||
| Independent MPPT trackers | 2Number of MPP trackers Official source ↗ | 3Number of MPP trackers Official source ↗ |
| MPPT operating window minimum | 230 VMPP voltage range Official source ↗ | 140 VMPPT operating voltage range Official source ↗ |
| MPPT operating window maximum | 480 VMPP voltage range Official source ↗ | 950 VMPPT operating voltage range Official source ↗ |
| DC operating voltage minimum | 65 VU_dc min - U_dc max Official source ↗ | Unknown |
| DC operating voltage maximum | 600 VU_dc min - U_dc max Official source ↗ | Unknown |
| Maximum PV input voltage | 600 VTask23 QC-approved exact-model/market manufacturer specification. Official source ↗ | 1100 VMax. input voltage Official source ↗ |
| Maximum input current per tracker/input | MPPT1 22 / MPPT2 12 AMax. input current (I_dc max), manufacturer two-MPPT topology preserved Official source ↗ | 40 AMax. input current per MPPT Official source ↗ |
| Maximum PV short-circuit current | MPPT1 41.25 / MPPT2 22 AMax. short circuit current, module array; exact two-MPPT scope Official source ↗ | 50 / 50 / 50 AMax. short-circuit current per MPPT; MPPT-specific values retained Official source ↗ |
| Efficiency & environment | ||
| Maximum conversion efficiency | 97.6 %Max. efficiency (PV-grid) Official source ↗ | 98.7 %Maximum efficiency Official source ↗ |
| European efficiency | Unknown | Unknown |
| Operating ambient temperature minimum | -40 °CAmbient temperature range; no extra derating curve inferred Official source ↗ | -30 °COperating temperature range Official source ↗ |
| Operating ambient temperature maximum | 60 °CAmbient temperature range; no extra derating curve inferred Official source ↗ | 60 °COperating temperature range Official source ↗ |
| Enclosure protection | IP66Degree of protection Official source ↗ | IP66Ingress Protection Rating Official source ↗ |
| Surge protection | Unknown | DC Type II; AC Type IIProtection table; exact model column Official source ↗ |
| Warranty | ||
| Warranty and eligibility | Unknown | Unknown |