PUBLIC CATALOGUE • 632 comparison-ready inverter records. Incomplete identities are not shown.
← Choose inverters

Compare inverters.

Exact market specifications side by side, limited to one reviewed comparison category.

Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.

String inverter 2 exact records · Differences include rating conditions and scope.
Edit selection
Inverter electrical comparison
SpecificationFronius Primo GEN24 6.0Fronius International GmbH · Europe / ROW current support selectorDeep comparison fields reviewedGW50K-SMT-L-G10GoodWe Technologies Co., Ltd. · Global catalog (country/grid exceptions separated as material variants)Deep comparison fields reviewed
AC output
Rated AC active power6000 WAC nominal output (P_ac,r)
Source unit W
Official source ↗
Technical Data > Output Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

50000 WNominal output power; exact source raw value '50 kW' kW. Converted exactly to website base unit; W and VA not interchanged.
Source unit W
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum AC apparent output6000 VAMax. output power (P_ac max); apparent-power unit preserved
Source unit VA
Official source ↗
Technical Data > Output Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

50000 VAMax. AC apparent power; exact source raw value '50 kVA' kVA. Converted exactly to website base unit; W and VA not interchanged.
Source unit VA
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Connection phases1Task23 QC-approved exact-model/market manufacturer specification.
Official source ↗
exact model identity; DC voltage/current/MPPT; AC nominal active W; max apparent VA; grid voltage/frequency
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained.
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

PV input & tracking
Independent MPPT trackers2Number of MPP trackers
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

6MPP trackers; exact model/market Task10 evidence reused.
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT operating window minimum230 VMPP voltage range
Source unit V
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

180 VMPPT operating range; endpoint of exact official range [180, 800], not the absolute DC limit.
Source unit V
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

MPPT operating window maximum480 VMPP voltage range
Source unit V
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

800 VMPPT operating range; endpoint of exact official range [180, 800], not the absolute DC limit.
Source unit V
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

DC operating voltage minimum65 VU_dc min - U_dc max
Source unit V
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Unknown
DC operating voltage maximum600 VU_dc min - U_dc max
Source unit V
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Unknown
Maximum PV input voltage600 VTask23 QC-approved exact-model/market manufacturer specification.
Source unit V
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

900 VMax. input voltage; exact model/market Task10 evidence reused.
Source unit V
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum input current per tracker/inputMPPT1 22 / MPPT2 12 AMax. input current (I_dc max), manufacturer two-MPPT topology preserved
Source unit A
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

42 AMax. input current per MPPT; per-MPPT/input maximum, not total inverter current.
Source unit A
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Maximum PV short-circuit currentMPPT1 41.25 / MPPT2 22 AMax. short circuit current, module array; exact two-MPPT scope
Source unit A
Official source ↗
Technical Data > Input Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

52.5 AMax. short circuit current per MPPT; per-MPPT/input maximum, not total inverter current.
Source unit A
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Efficiency & environment
Maximum conversion efficiency97.6 %Max. efficiency (PV-grid)
Source unit %
Official source ↗
Technical Data > Efficiency
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

98.6 %Max. efficiency; exact model/market Task10 evidence reused.
Source unit %
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

European efficiencyUnknown98.1 %European efficiency; exact model/market Task10 evidence reused.
Source unit %
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Operating ambient temperature minimum-40 °CAmbient temperature range; no extra derating curve inferred
Source unit °C
Official source ↗
Technical Data > General Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

-30 °COperating temp; lower endpoint of exact official range [-30, 60].
Source unit °C
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Operating ambient temperature maximum60 °CAmbient temperature range; no extra derating curve inferred
Source unit °C
Official source ↗
Technical Data > General Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

60 °COperating temp; upper endpoint of exact official range [-30, 60].
Source unit °C
Official source ↗
Technical Data table
Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Enclosure protectionIP66Degree of protection
Official source ↗
Technical Data > General Data
Revision Unknown · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval.
Official source ↗
Official technical data / Ingress Protection Rating; exact family/model applicability for GW50K-SMT-L-G10.
Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Surge protectionUnknownDC: Type II (Type I + II optional); AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated.
Official source ↗
Official Protection table / surge-protection rows for family containing exact model GW50K-SMT-L-G10.
Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02

Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00

Warranty
Warranty and eligibilityUnknownUnknown