Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
| Specification | Fronius Primo GEN24 6.0Fronius International GmbH · Europe / ROW current support selectorDeep comparison fields reviewed | GW50K-SMT-L-G10GoodWe Technologies Co., Ltd. · Global catalog (country/grid exceptions separated as material variants)Deep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 6000 WAC nominal output (P_ac,r) Source unit W Official source ↗ Technical Data > Output Data Revision Unknown · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 50000 WNominal output power; exact source raw value '50 kW' kW. Converted exactly to website base unit; W and VA not interchanged. Source unit W Official source ↗ Technical Data table Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum AC apparent output | 6000 VAMax. output power (P_ac max); apparent-power unit preserved Source unit VA Official source ↗ Technical Data > Output Data Revision Unknown · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 50000 VAMax. AC apparent power; exact source raw value '50 kVA' kVA. Converted exactly to website base unit; W and VA not interchanged. Source unit VA Official source ↗ Technical Data table Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Connection phases | 1Task23 QC-approved exact-model/market manufacturer specification. Official source ↗ exact model identity; DC voltage/current/MPPT; AC nominal active W; max apparent VA; grid voltage/frequency Revision Unknown · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 3Connection phase count bound to Task10 exact identity (three-phase); nominal wiring/voltage evidence retained. Official source ↗ Technical Data table Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| PV input & tracking | ||
| Independent MPPT trackers | 2Number of MPP trackers Official source ↗ Technical Data > Input Data Revision Unknown · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 6MPP trackers; exact model/market Task10 evidence reused. Official source ↗ Technical Data table Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window minimum | 230 VMPP voltage range Source unit V Official source ↗ Technical Data > Input Data Revision Unknown · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 180 VMPPT operating range; endpoint of exact official range [180, 800], not the absolute DC limit. Source unit V Official source ↗ Technical Data table Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| MPPT operating window maximum | 480 VMPP voltage range Source unit V Official source ↗ Technical Data > Input Data Revision Unknown · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 800 VMPPT operating range; endpoint of exact official range [180, 800], not the absolute DC limit. Source unit V Official source ↗ Technical Data table Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| DC operating voltage minimum | 65 VU_dc min - U_dc max Source unit V Official source ↗ Technical Data > Input Data Revision Unknown · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | Unknown |
| DC operating voltage maximum | 600 VU_dc min - U_dc max Source unit V Official source ↗ Technical Data > Input Data Revision Unknown · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | Unknown |
| Maximum PV input voltage | 600 VTask23 QC-approved exact-model/market manufacturer specification. Source unit V Official source ↗ Technical Data > Input Data Revision Unknown · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 900 VMax. input voltage; exact model/market Task10 evidence reused. Source unit V Official source ↗ Technical Data table Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum input current per tracker/input | MPPT1 22 / MPPT2 12 AMax. input current (I_dc max), manufacturer two-MPPT topology preserved Source unit A Official source ↗ Technical Data > Input Data Revision Unknown · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 42 AMax. input current per MPPT; per-MPPT/input maximum, not total inverter current. Source unit A Official source ↗ Technical Data table Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Maximum PV short-circuit current | MPPT1 41.25 / MPPT2 22 AMax. short circuit current, module array; exact two-MPPT scope Source unit A Official source ↗ Technical Data > Input Data Revision Unknown · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 52.5 AMax. short circuit current per MPPT; per-MPPT/input maximum, not total inverter current. Source unit A Official source ↗ Technical Data table Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Efficiency & environment | ||
| Maximum conversion efficiency | 97.6 %Max. efficiency (PV-grid) Source unit % Official source ↗ Technical Data > Efficiency Revision Unknown · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 98.6 %Max. efficiency; exact model/market Task10 evidence reused. Source unit % Official source ↗ Technical Data table Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| European efficiency | Unknown | 98.1 %European efficiency; exact model/market Task10 evidence reused. Source unit % Official source ↗ Technical Data table Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Operating ambient temperature minimum | -40 °CAmbient temperature range; no extra derating curve inferred Source unit °C Official source ↗ Technical Data > General Data Revision Unknown · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | -30 °COperating temp; lower endpoint of exact official range [-30, 60]. Source unit °C Official source ↗ Technical Data table Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Operating ambient temperature maximum | 60 °CAmbient temperature range; no extra derating curve inferred Source unit °C Official source ↗ Technical Data > General Data Revision Unknown · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | 60 °COperating temp; upper endpoint of exact official range [-30, 60]. Source unit °C Official source ↗ Technical Data table Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Enclosure protection | IP66Degree of protection Official source ↗ Technical Data > General Data Revision Unknown · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 | IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval. Official source ↗ Official technical data / Ingress Protection Rating; exact family/model applicability for GW50K-SMT-L-G10. Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Surge protection | Unknown | DC: Type II (Type I + II optional); AC: Type IIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ Official Protection table / surge-protection rows for family containing exact model GW50K-SMT-L-G10. Revision GoodWe-Single page-20260512-EN-V2.1 · Checked 2026-10-02 Source check overdue · Last checked 2026-11-17T21:53:45.238651+00:00 |
| Warranty | ||
| Warranty and eligibility | Unknown | Unknown |