Compare inverters.
Exact market specifications side by side, limited to one reviewed comparison category.
Comparison does not establish module compatibility, string sizing, grid approval or safety. W and VA remain separate ratings.
Hybrid / smart energy inverter
2 exact records
Edit selection
| Specification | GW3600-ES-C10GoodWe Technologies Co., Ltd. · Global / ROW (GoodWe global site; regional footnotes retained)Deep comparison fields reviewed | Fronius Primo GEN24 8.0 PlusFronius International GmbH · Europe / ROW current selectorDeep comparison fields reviewed |
|---|---|---|
| AC output | ||
| Rated AC active power | 3600 Wnominal/rated active power; exact source raw value '3.6' kW. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ | 8000 WAC nominal output Official source ↗ |
| Maximum AC apparent output | 3960 VAmaximum apparent power; exact source raw value '3.96' kVA. Converted exactly to website base unit; W and VA not interchanged. Official source ↗ | 8000 VAmaximum output power Official source ↗ |
| Connection phases | 1Connection phase count bound to Task10 exact identity (Single phase); nominal wiring/voltage evidence retained. Official source ↗ | single-phaseExact current product page; Europe/ROW selector Official source ↗ |
| PV input & tracking | ||
| Independent MPPT trackers | 2count; exact model/market Task10 evidence reused. Official source ↗ | 2 Official source ↗ |
| MPPT operating window minimum | 60 Voperating range; endpoint of exact official range [60, 550], not the absolute DC limit. Official source ↗ | 260 VReviewed MPPT/usable MPP operating window minimum Official source ↗ |
| MPPT operating window maximum | 550 Voperating range; endpoint of exact official range [60, 550], not the absolute DC limit. Official source ↗ | 480 VReviewed MPPT/usable MPP operating window maximum Official source ↗ |
| DC operating voltage minimum | Unknown | Unknown |
| DC operating voltage maximum | Unknown | Unknown |
| Maximum PV input voltage | 600 Vmaximum; exact model/market Task10 evidence reused. Official source ↗ | 600 Vmaximum of DC input range Official source ↗ |
| Maximum input current per tracker/input | 20 Aper-MPPT maximum; per-MPPT/input maximum, not total inverter current. Official source ↗ | 22 / 22 APV1/PV2 scope Official source ↗ |
| Maximum PV short-circuit current | 26 Aper-MPPT maximum; per-MPPT/input maximum, not total inverter current. Official source ↗ | 41.25 / 36 Amodule-array PV1/PV2 scope Official source ↗ |
| Efficiency & environment | ||
| Maximum conversion efficiency | 97.6 %maximum efficiency; exact model/market Task10 evidence reused. Official source ↗ | 97.3 %PV-to-grid maximum efficiency Official source ↗ |
| European efficiency | 96.2 %European efficiency; exact model/market Task10 evidence reused. Official source ↗ | Unknown |
| Operating ambient temperature minimum | -35 °Coperating range; lower endpoint of exact official range [-35, 60]. Official source ↗ | -40 °COperating ambient temperature minimum Official source ↗ |
| Operating ambient temperature maximum | 60 °Coperating range; upper endpoint of exact official range [-35, 60]. Official source ↗ | 60 °COperating ambient temperature maximum Official source ↗ |
| Enclosure protection | IP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval. Official source ↗ | IP66 Official source ↗ |
| Surge protection | DC: Type III; AC: Type IIIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated. Official source ↗ | Unknown |
| Warranty | ||
| Warranty and eligibility | Unknown | Unknown |