Hybrid / smart energy inverter 2 exact records
Edit selection
Inverter electrical comparison
SpecificationGW3600-ES-C10GoodWe Technologies Co., Ltd. · Global / ROW (GoodWe global site; regional footnotes retained)Deep comparison fields reviewedFronius Primo GEN24 10.0 PlusFronius International GmbH · Europe / ROW current selectorDeep comparison fields reviewed
AC output
Rated AC active power3600 Wnominal/rated active power; exact source raw value '3.6' kW. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
10000 WAC nominal output
Official source ↗
Maximum AC apparent output3960 VAmaximum apparent power; exact source raw value '3.96' kVA. Converted exactly to website base unit; W and VA not interchanged.
Official source ↗
10000 VAmaximum output power
Official source ↗
Connection phases1Connection phase count bound to Task10 exact identity (Single phase); nominal wiring/voltage evidence retained.
Official source ↗
single-phaseExact current product page; Europe/ROW selector
Official source ↗
PV input & tracking
Independent MPPT trackers2count; exact model/market Task10 evidence reused.
Official source ↗
2
Official source ↗
MPPT operating window minimum60 Voperating range; endpoint of exact official range [60, 550], not the absolute DC limit.
Official source ↗
260 VReviewed MPPT/usable MPP operating window minimum
Official source ↗
MPPT operating window maximum550 Voperating range; endpoint of exact official range [60, 550], not the absolute DC limit.
Official source ↗
480 VReviewed MPPT/usable MPP operating window maximum
Official source ↗
DC operating voltage minimumUnknownUnknown
DC operating voltage maximumUnknownUnknown
Maximum PV input voltage600 Vmaximum; exact model/market Task10 evidence reused.
Official source ↗
600 Vmaximum of DC input range
Official source ↗
Maximum input current per tracker/input20 Aper-MPPT maximum; per-MPPT/input maximum, not total inverter current.
Official source ↗
22 / 22 APV1/PV2 scope
Official source ↗
Maximum PV short-circuit current26 Aper-MPPT maximum; per-MPPT/input maximum, not total inverter current.
Official source ↗
41.25 / 36 Amodule-array PV1/PV2 scope
Official source ↗
Efficiency & environment
Maximum conversion efficiency97.6 %maximum efficiency; exact model/market Task10 evidence reused.
Official source ↗
97.3 %PV-to-grid maximum efficiency
Official source ↗
European efficiency96.2 %European efficiency; exact model/market Task10 evidence reused.
Official source ↗
Unknown
Operating ambient temperature minimum-35 °Coperating range; lower endpoint of exact official range [-35, 60].
Official source ↗
-40 °COperating ambient temperature minimum
Official source ↗
Operating ambient temperature maximum60 °Coperating range; upper endpoint of exact official range [-35, 60].
Official source ↗
60 °COperating ambient temperature maximum
Official source ↗
Enclosure protectionIP66Official enclosure ingress-protection rating; catalogue description only, not a safety or suitability approval.
Official source ↗
IP66
Official source ↗
Surge protectionDC: Type III; AC: Type IIIOfficial surge-protection configuration for this exact model family; optional enhancements are preserved verbatim where stated.
Official source ↗
Unknown
Warranty
Warranty and eligibilityUnknownUnknown